Request Quote
(Ships tomorrow)
Circuit Breaker Thermal 16A 240VAC 28VDC SCHURTER 4410.0152
Part Overview
The SCHURTER 4410.0152 is a single-pole thermal circuit breaker rated for 16A at 240V AC and 28V DC, designed for panel mount applications with push-to-reset actuation. This component is classified as Active product status and maintains full RoHS3 compliance. Equivalent substitute parts are identified based on matching electrical ratings, mechanical mounting specifications, and functional characteristics to ensure direct interchangeability in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4410.0152 |
| Manufacturer | SCHURTER Inc. |
| Series | T12 |
| Breaker Type | Thermal |
| Current Rating | 16A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the SCHURTER 4410.0152 is determined by the following critical parameters:
- Current Rating: 16A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 28V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Number of Poles: 1 (exact match required)
The E-T-A 1658-G21-02-P10-16A meets all substitution criteria through identical electrical and mechanical specifications, enabling direct replacement in applications requiring 16A thermal circuit protection at dual voltage ratings.
Parameter Comparison
| Parameter | SCHURTER 4410.0152 | E-T-A 1658-G21-02-P10-16A |
|---|---|---|
| Manufacturer Part Number | 4410.0152 | 1658-G21-02-P10-16A |
| Manufacturer | SCHURTER Inc. | E-T-A |
| Series | T12 | 1658 |
| Breaker Type | Thermal | Thermal |
| Current Rating (Amps) | 16A | 16A |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 28V | 28V |
| Mounting Type | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 |
| Product Status | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.20.0020 | 8536.20.0020 |
Engineering Selection Recommendations
Both the SCHURTER 4410.0152 and E-T-A 1658-G21-02-P10-16A are Active product status components with full RoHS3 compliance and REACH Unaffected designation. The E-T-A substitute carries additional approval certifications including CE, CSA C22.2 No 235, IEC 60934, and UL1077, providing expanded regulatory coverage for applications requiring multi-standard compliance. Selection between these parts should be based on supply availability, lead time requirements, and specific regulatory certifications mandated by the end application.
Frequently Asked Questions (FAQ)
Q: Can the E-T-A 1658-G21-02-P10-16A directly replace the SCHURTER 4410.0152?
A: Yes. Both components share identical electrical ratings (16A, 240V AC, 28V DC), thermal breaker type, panel mount configuration, push-to-reset actuation, and single-pole design. Direct substitution is supported without circuit modification.
Q: What parameters must match for thermal circuit breaker substitution?
A: Current rating, AC voltage rating, DC voltage rating, breaker type, mounting type, actuator type, and pole count must all match exactly. Deviations in any of these parameters disqualify a part as a substitute.
Q: Are there compliance differences between these two parts?
A: Both parts meet RoHS3 and REACH requirements. The E-T-A 1658-G21-02-P10-16A includes additional certifications (CE, CSA C22.2 No 235, IEC 60934, UL1077) that may be required for specific regional or application-specific compliance mandates.
Q: What is the packaging format for these components?
A: Both parts are supplied in Bulk packaging format suitable for production assembly environments.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts