Request Quote
(Ships tomorrow)
SCHURTER 4410.0106 Thermal Circuit Breaker - Equivalent & Substitute Parts
Part Overview
The SCHURTER 4410.0106 is a single-pole thermal circuit breaker rated for 10A at 240V AC and 28V DC, configured with push-to-reset actuation and panel mount installation. This component is classified as Active product status and maintains full ROHS3 compliance. Equivalent substitute parts are necessary to support supply chain flexibility, inventory management, and continuity of operations when the primary part becomes unavailable or when design requirements permit cross-manufacturer qualification.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4410.0106 |
| Manufacturer | SCHURTER Inc. |
| Series | T12 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the SCHURTER 4410.0106 is determined by strict equivalence across the following parameters:
- Current Rating: 10A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 28V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Number of Poles: 1 (exact match required)
- RoHS Status: ROHS3 Compliant (exact match required)
The three E-T-A parts listed below meet all substitution criteria and are classified as parametric equivalents to the SCHURTER 4410.0106.
Parameter Comparison
| Parameter | SCHURTER 4410.0106 | E-T-A 1658-G21-01-P10-10A | E-T-A 1658-G21-02-P10-10A | E-T-A 1658-G41-02-P10-10A |
|---|---|---|---|---|
| Manufacturer | SCHURTER Inc. | E-T-A | E-T-A | E-T-A |
| Series | T12 | 1658 | 1658 | 1658 |
| Breaker Type | Thermal | Thermal | Thermal | Thermal |
| Current Rating (Amps) | 10A | 10A | 10A | 10A |
| Voltage Rating - AC | 240V | 240V | 240V | 240V |
| Voltage Rating - DC | 28V | 28V | 28V | 28V |
| Mounting Type | Panel Mount | Panel Mount | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 | 1 | 1 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Product Status | Active | Active | Active | Active |
Engineering Selection Recommendations
All three E-T-A substitute parts (1658-G21-01-P10-10A, 1658-G21-02-P10-10A, and 1658-G41-02-P10-10A) are qualified as direct parametric equivalents to the SCHURTER 4410.0106. Selection among these alternatives is supported by the following factors:
- All substitute parts maintain Active product status, ensuring long-term availability and supply chain stability.
- All parts are ROHS3 compliant and REACH unaffected, meeting regulatory requirements equivalent to the primary part.
- E-T-A substitute parts carry approval certifications including CE, CSA C22.2 No 235, IEC 60934, and UL1077, providing additional compliance documentation for applications requiring third-party validation.
- Inventory levels for E-T-A parts range from 984 to 1277 pieces, supporting immediate procurement without lead time constraints.
Frequently Asked Questions (FAQ)
Q: Can E-T-A 1658 series parts be used interchangeably with SCHURTER 4410.0106?
A: Yes. The three E-T-A parts listed (1658-G21-01-P10-10A, 1658-G21-02-P10-10A, and 1658-G41-02-P10-10A) are parametric equivalents. They match all critical electrical and mechanical specifications: 10A current rating, 240V AC / 28V DC voltage ratings, thermal breaker type, panel mount configuration, push-to-reset actuation, and single-pole design.
Q: What determines if a part can substitute for the SCHURTER 4410.0106?
A: Substitution requires exact equivalence across current rating, voltage ratings (both AC and DC), breaker type, mounting type, actuator type, number of poles, and RoHS compliance status. Any deviation in these parameters disqualifies a part from substitution.
Q: Are there differences between the three E-T-A substitute parts?
A: The three E-T-A parts are parametric equivalents with identical electrical and mechanical specifications. Differences exist only in internal design variants (indicated by the G21 vs. G41 designations and the 01 vs. 02 suffixes), which do not affect functional compatibility or performance in applications requiring the specified parameters.
Q: What compliance certifications apply to the substitute parts?
A: E-T-A substitute parts carry CE, CSA C22.2 No 235, IEC 60934, and UL1077 certifications. These certifications align with the regulatory framework applicable to thermal circuit breakers in the specified voltage and current classes.
Q: Is packaging identical across all parts?
A: All parts are supplied in Bulk packaging. Physical form factor and panel mount interface are consistent across the SCHURTER primary part and all E-T-A substitutes.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts


