Circuit Breaker Thermal 5A 240VAC 28VDC SCHURTER 4410.0101
Part Overview
The SCHURTER 4410.0101 is a single-pole thermal circuit breaker rated for 5A at 240V AC and 28V DC, designed for panel mount applications with push-to-reset actuation. This component is classified as Active product status and maintains full compliance with international safety standards including UL1077, IEC 60934, and CSA C22.2 No 235. Equivalent substitute parts are necessary to ensure supply chain continuity, support procurement flexibility, and provide alternative sourcing options when the primary part becomes unavailable or when design requirements permit functional equivalents.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4410.0101 |
| Manufacturer | SCHURTER Inc. |
| Series | T12 |
| Breaker Type | Thermal |
| Current Rating | 5A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4410.0101 are qualified based on strict electrical and mechanical parameter matching. The following criteria determine substitution eligibility:
Critical Parameters for Substitution:
- Current Rating: 5A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 28V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Number of Poles: 1 (exact match required)
The E-T-A 1658 series parts (1658-G21-01-P10-5A and 1658-G21-02-P10-5A) meet all critical electrical and mechanical parameters, making them parametric equivalents suitable for direct substitution in applications where the SCHURTER 4410.0101 is specified.
Parameter Comparison
| Parameter | SCHURTER 4410.0101 | E-T-A 1658-G21-01-P10-5A | E-T-A 1658-G21-02-P10-5A |
|---|---|---|---|
| Breaker Type | Thermal | Thermal | Thermal |
| Current Rating (Amps) | 5A | 5A | 5A |
| Voltage Rating - AC | 240V | 240V | 240V |
| Voltage Rating - DC | 28V | 28V | 28V |
| Mounting Type | Panel Mount | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 | 1 |
| Product Status | Active | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Approval Agency | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CE, CSA C22.2 No 235, IEC 60934, UL1077 | CE, CSA C22.2 No 235, IEC 60934, UL1077 |
Engineering Selection Recommendations
Both E-T-A substitute parts maintain Active product status and carry full compliance with core international safety standards (CSA C22.2 No 235, IEC 60934, UL1077). The E-T-A 1658 series includes additional CE certification, expanding regulatory coverage for European markets. All three parts are ROHS3 compliant and carry identical electrical specifications, confirming functional equivalence for 5A thermal circuit breaker applications at 240V AC and 28V DC.
Selection between the SCHURTER 4410.0101 and E-T-A substitutes should be based on availability, lead time, and procurement requirements, as all parts satisfy identical electrical and mechanical specifications for panel-mount thermal protection circuits.
Frequently Asked Questions (FAQ)
Q: Can E-T-A 1658-G21-01-P10-5A and 1658-G21-02-P10-5A be used interchangeably with SCHURTER 4410.0101?
A: Yes. Both E-T-A parts are parametric equivalents matching all critical specifications: 5A current rating, 240V AC / 28V DC voltage ratings, thermal breaker type, panel mount configuration, and push-to-reset actuation. All three parts are Active status and ROHS3 compliant.
Q: Are there differences in approval certifications between the main part and substitutes?
A: The SCHURTER 4410.0101 includes EN 60934 and GB 17701 certifications, while E-T-A substitutes include CE certification. All three parts share CSA C22.2 No 235, IEC 60934, and UL1077 approvals, covering North American and international regulatory requirements.
Q: What packaging format is available for these parts?
A: All parts are supplied in Bulk packaging format.
Q: Are there inventory considerations when selecting between these parts?
A: Current inventory levels are: SCHURTER 4410.0101 (1071 pcs), E-T-A 1658-G21-01-P10-5A (1673 pcs), and E-T-A 1658-G21-02-P10-5A (1153 pcs). Availability should be confirmed with your supplier for project-specific lead time requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts