Request Quote
(Ships tomorrow)
Circuit Breaker Thermal 600mA 240VAC 28VDC SCHURTER 4410.0039
Part Overview
The SCHURTER 4410.0039 is a thermal circuit breaker designed for panel mount applications, rated at 600mA with dual voltage capability (240V AC / 28V DC). This component provides overcurrent protection with push-to-reset actuation in a single-pole configuration. The part is currently active in production with ROHS3 compliance and maintains robust inventory availability. Alternative models may be required due to supply constraints, regional availability, or specific application requirements within the same electrical and mechanical parameter space.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4410.0039 |
| Manufacturer | SCHURTER Inc. |
| Series | T12 |
| Breaker Type | Thermal |
| Current Rating | 600mA |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Number of Poles | 1 |
| Actuator Type | Push to Reset |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the SCHURTER 4410.0039 is determined by strict equivalence across the following critical parameters:
- Current Rating: 600mA (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 28V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Number of Poles: 1 (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Series: T12 (same product family)
The substitute part SCHURTER 4410.017 meets all electrical and mechanical equivalence criteria, maintaining identical performance characteristics within the specified parameter set.
Parameter Comparison
| Parameter | 4410.0039 (Main) | 4410.017 (Substitute) | Match Status |
|---|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. | Identical |
| Series | T12 | T12 | Identical |
| Breaker Type | Thermal | Thermal | Identical |
| Current Rating (Amps) | 600mA | 600mA | Identical |
| Voltage Rating - AC | 240V | 240V | Identical |
| Voltage Rating - DC | 28V | 28V | Identical |
| Mounting Type | Panel Mount | Panel Mount | Identical |
| Number of Poles | 1 | 1 | Identical |
| Actuator Type | Push to Reset | Push to Reset | Identical |
| Product Status | Active | Active | Identical |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Identical |
| REACH Status | REACH Unaffected | REACH Unaffected | Identical |
| ECCN | EAR99 | EAR99 | Identical |
| HTSUS Code | 8536.20.0020 | 8536.20.0020 | Identical |
Engineering Selection Recommendations
Both the SCHURTER 4410.0039 and 4410.017 are active production components with full ROHS3 compliance and REACH unaffected status. The 4410.017 carries additional certification documentation (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), providing expanded regulatory coverage for applications requiring multi-standard compliance. Selection between these parts should be based on supply availability, inventory position, and specific regional certification requirements. Both components are electrically and mechanically interchangeable within the T12 series thermal circuit breaker platform.
Frequently Asked Questions (FAQ)
Q: Can the 4410.017 directly replace the 4410.0039 in existing designs?
A: Yes. Both parts are identical across all critical electrical parameters (600mA, 240V AC, 28V DC) and mechanical specifications (panel mount, single-pole, push-to-reset thermal actuation). No design modification is required.
Q: What is the difference between these two part numbers?
A: The parts are electrically and mechanically equivalent. The 4410.017 includes documented compliance with additional international standards (CSA, EN, GB, IEC, UL). Both maintain ROHS3 and REACH compliance.
Q: Are there packaging differences between 4410.0039 and 4410.017?
A: Both parts are supplied in bulk packaging. No packaging format differences affect substitution eligibility.
Q: Which part should be selected for new designs?
A: Selection depends on supply chain requirements and certification scope. For applications requiring multi-standard documentation, the 4410.017 provides explicit certification records. For standard applications, either part meets the electrical and mechanical requirements.
Q: Do these parts have identical thermal response characteristics?
A: Both parts are thermal-type circuit breakers within the T12 series. Substitution is based on the provided electrical and mechanical parameters. Thermal response characteristics are determined by the thermal breaker type classification.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts