SCHURTER 4404.0041 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4404.0041 is a single-pole thermal circuit breaker rated for 5A at 240V AC and 48V DC, configured with push-to-reset actuation and panel mount installation. This component is Active status and ROHS3 compliant. Substitute parts are identified based on identical electrical ratings, mechanical configuration, and functional equivalence within the SCHURTER thermal breaker product line.

Substiute Parts

4404.0041
SCHURTER Inc.In Stock: 11544404.0041 Datasheet
4404.0041
Current Part
4400.0006
SCHURTER Inc.In Stock: 12234400.0006 Datasheet
4400.0006
Parametric Equivalent
4400.0026
SCHURTER Inc.In Stock: 11344400.0026 Datasheet
4400.0026
Parametric Equivalent
4400.0067
SCHURTER Inc.In Stock: 9844400.0067 Datasheet
4400.0067
Parametric Equivalent
4400.0194
SCHURTER Inc.In Stock: 8394400.0194 Datasheet
4400.0194
Parametric Equivalent
4400.0515
SCHURTER Inc.In Stock: 8514400.0515 Datasheet
4400.0515
Parametric Equivalent
4400.0775
SCHURTER Inc.In Stock: 12524400.0775 Datasheet
4400.0775
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4404.0041
Manufacturer SCHURTER Inc.
Series T9-611
Breaker Type Thermal
Current Rating 5A
Voltage Rating - AC 240V
Voltage Rating - DC 48V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of SCHURTER thermal circuit breakers is determined by strict equivalence across the following parameters:

  • Current Rating: 5A (all substitutes match)
  • Voltage Rating - AC: 240V (all substitutes match)
  • Voltage Rating - DC: 48V (all substitutes match)
  • Breaker Type: Thermal (all substitutes match)
  • Mounting Type: Panel Mount (all substitutes match)
  • Actuator Type: Push to Reset (all substitutes match)
  • Number of Poles: 1 (all substitutes match)
  • RoHS Status: ROHS3 Compliant (all substitutes match)

All identified substitute parts maintain identical electrical and mechanical specifications. Differences exist only in series designation (T9-611 vs. T11) and approval agency certifications on certain variants.

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Mounting Type Actuator Type Poles Product Status RoHS Status Inventory (Pcs)
4404.0041 T9-611 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 1053
4400.0006 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 1115
4400.0026 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 1026
4400.0067 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 913
4400.0194 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 753
4400.0515 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 838
4400.0775 T11 5A 240V 48V Panel Mount Push to Reset 1 Active ROHS3 Compliant 1225

Engineering Selection Recommendations

All substitute parts listed are Active status components with ROHS3 compliance. The primary distinction between 4404.0041 and its substitutes is series designation: the main part belongs to the T9-611 series, while all substitutes are T11 series variants. Substitute parts 4400.0006, 4400.0026, 4400.0067, 4400.0194, 4400.0515, and 4400.0775 carry approval agency certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Selection among substitutes may be based on inventory availability and required regulatory certifications for the application.

Frequently Asked Questions (FAQ)

Q: Can SCHURTER 4400.0006 replace SCHURTER 4404.0041?

A: Yes. Both parts are single-pole thermal circuit breakers with identical electrical ratings (5A, 240V AC, 48V DC) and mechanical configuration (panel mount, push-to-reset actuation). The primary difference is series designation (T9-611 vs. T11).

Q: What determines if a part is a valid substitute?

A: Substitution is valid when the following parameters match: current rating (5A), AC voltage rating (240V), DC voltage rating (48V), breaker type (thermal), mounting type (panel mount), actuator type (push to reset), and pole count (1). All listed substitutes meet these criteria.

Q: Are there differences in approval certifications among the substitute parts?

A: The main part 4404.0041 does not list specific approval agencies. All T11 series substitutes (4400.0006, 4400.0026, 4400.0067, 4400.0194, 4400.0515, 4400.0775) carry certifications for CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Verify certification requirements for your specific application.

Q: Do all substitutes have the same RoHS compliance status?

A: Yes. The main part 4404.0041 and all substitute parts are ROHS3 compliant.

Q: Which substitute part has the highest inventory availability?

A: SCHURTER 4400.0775 has the highest inventory at 1225 pieces, followed by 4400.0006 at 1115 pieces.

Request Quote (Ships tomorrow)