SCHURTER 4404.0029 Circuit Breaker Thermal 4A 240VAC 48VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4404.0029 is a thermal circuit breaker rated for 4A at 240V AC and 48V DC, designed for panel mount applications with push-to-reset actuation. This single-pole breaker is actively manufactured and holds CSA, EN, GB, IEC, and UL certifications. Substitute parts are identified when equivalent electrical ratings, mechanical mounting, and functional characteristics align with the original specification, ensuring direct interchangeability in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4404.0029 |
| Manufacturer | SCHURTER Inc. |
| Series | T9-711 |
| Breaker Type | Thermal |
| Current Rating | 4A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 48V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Active |
| Approval Agencies | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the SCHURTER 4404.0029 is determined by strict equivalence across the following parameters:
- Current Rating: 4A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 48V
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Push to Reset
- Number of Poles: 1
- Approval Agencies: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
The substitute part 4404.0019 meets all electrical and mechanical requirements for direct replacement. Both parts are manufactured by SCHURTER Inc., maintain identical functional specifications, and carry equivalent regulatory certifications. The difference in series designation (T9-711 vs. T9-311) reflects internal product line evolution while preserving electrical and mechanical compatibility.
Parameter Comparison
| Parameter | 4404.0029 (Main) | 4404.0019 (Substitute) |
|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. |
| Breaker Type | Thermal | Thermal |
| Current Rating | 4A | 4A |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 48V | 48V |
| Mounting Type | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 |
| Product Status | Active | Active |
| Approval Agencies | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
Both the SCHURTER 4404.0029 and 4404.0019 are active products with identical electrical ratings, mechanical form factors, and regulatory certifications. Selection between these parts is based on availability and inventory status. The 4404.0019 carries 1052 pieces in stock compared to 1042 pieces for the 4404.0029, making either part suitable for immediate procurement. Both parts comply with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards, and both maintain ROHS3 compliance. No technical differentiation exists between these parts for circuit protection applications requiring 4A thermal protection at 240V AC or 48V DC.
Frequently Asked Questions (FAQ)
Q: Can the 4404.0019 directly replace the 4404.0029 in existing designs?
A: Yes. Both parts are electrically and mechanically identical with matching current ratings (4A), voltage ratings (240V AC, 48V DC), mounting configuration (panel mount), and actuation method (push to reset). All regulatory certifications are equivalent.
Q: What is the difference between the T9-711 and T9-311 series designations?
A: The series designation reflects internal SCHURTER product line classification. Both series maintain identical electrical specifications and mechanical compatibility for this 4A thermal breaker application.
Q: Are both parts RoHS compliant?
A: Yes. Both the 4404.0029 and 4404.0019 are ROHS3 compliant and carry identical environmental compliance status.
Q: Which certifications apply to both substitute parts?
A: Both parts hold certifications under CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077, ensuring regulatory acceptance in equivalent markets and applications.
Q: Is there a packaging difference between these parts?
A: Both parts are supplied in box packaging. No packaging differentiation affects substitution eligibility.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts