SCHURTER 4400.0526 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4400.0526 is a thermal circuit breaker rated for 1A at 240V AC and 48V DC, designed for panel mount applications with push-to-reset actuation. This single-pole breaker is part of the T11 series and maintains active product status with full regulatory compliance. Equivalent substitute parts are available to support procurement flexibility, inventory management, and supply chain continuity.

Substiute Parts

4400.0526
SCHURTER Inc.In Stock: 7294400.0526 Datasheet
4400.0526
Current Part
4400.0008
SCHURTER Inc.In Stock: 10454400.0008 Datasheet
4400.0008
Parametric Equivalent
4400.0019
SCHURTER Inc.In Stock: 9844400.0019 Datasheet
4400.0019
Parametric Equivalent
4400.0063
SCHURTER Inc.In Stock: 13314400.0063 Datasheet
4400.0063
Parametric Equivalent
4400.0082
SCHURTER Inc.In Stock: 9174400.0082 Datasheet
4400.0082
Parametric Equivalent
4400.0169
SCHURTER Inc.In Stock: 11704400.0169 Datasheet
4400.0169
Parametric Equivalent
4400.022
SCHURTER Inc.In Stock: 10394400.022 Datasheet
4400.022
Parametric Equivalent
4400.0447
SCHURTER Inc.In Stock: 12214400.0447 Datasheet
4400.0447
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer SCHURTER Inc.
Series T11
Breaker Type Thermal
Current Rating 1A
Voltage Rating - AC 240V
Voltage Rating - DC 48V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Packaging Bulk
Product Status Active

Substitute Part Grouping Explanation

All substitute parts listed are parametric equivalents to the SCHURTER 4400.0526. Substitution is based on identical electrical and mechanical specifications:

  • Current Rating: 1A
  • Voltage Rating: 240V AC / 48V DC
  • Breaker Type: Thermal
  • Mounting Configuration: Panel Mount
  • Actuation Method: Push to Reset
  • Pole Configuration: Single Pole (1P)
  • Series Classification: T11
  • Manufacturer: SCHURTER Inc.

These parts are interchangeable for applications requiring identical electrical performance and physical form factor. All substitute parts maintain the same regulatory certifications and compliance status as the primary part number.

Parameter Comparison

Part Number Current Rating Voltage AC Voltage DC Breaker Type Mounting Type Actuator Type Poles Series Product Status Inventory (Pcs)
4400.0526 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 648
4400.0008 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 996
4400.0019 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 927
4400.0063 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 1302
4400.0082 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 870
4400.0169 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 1100
4400.022 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 989
4400.0447 1A 240V 48V Thermal Panel Mount Push to Reset 1 T11 Active 1158

Engineering Selection Recommendations

All substitute part numbers are fully qualified equivalents with identical electrical ratings and mechanical specifications. Selection among these parts may be based on:

  • Inventory availability and lead time requirements
  • Procurement source preferences
  • Regulatory compliance verification for specific application jurisdictions

All listed parts maintain active product status and comply with the same certification standards: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. All parts are ROHS3 compliant and REACH unaffected. The HTSUS classification 8536.20.0020 applies uniformly across all part numbers.

Frequently Asked Questions (FAQ)

Q: Are all listed part numbers electrically interchangeable with the 4400.0526?

A: Yes. All substitute parts share identical current ratings (1A), voltage ratings (240V AC / 48V DC), breaker type (thermal), and actuation method (push to reset). They are direct parametric equivalents.

Q: Do the substitute parts have the same physical dimensions and panel mount configuration?

A: Yes. All parts are specified as single-pole, panel mount thermal breakers with push-to-reset actuation in the T11 series. Physical form factor and mounting interface are identical.

Q: Are there differences in regulatory certifications between the main part and substitutes?

A: All parts carry the same regulatory approvals: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Compliance status is uniform across all part numbers.

Q: What is the difference between these part numbers if they are all equivalent?

A: The part numbers represent different manufacturing batches or internal SCHURTER designations. From an engineering and application perspective, they are functionally identical and interchangeable.

Q: Can I substitute any of these parts in an existing design without circuit modification?

A: Yes. All substitute parts meet identical electrical and mechanical specifications. No circuit redesign or panel modification is required for substitution.

Q: Are all parts available in bulk packaging?

A: Yes. All listed part numbers are supplied in bulk packaging format.

Request Quote (Ships tomorrow)