SCHURTER 4400.0415 Circuit Breaker Thermal 200mA 240VAC 48VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4400.0415 is a single-pole thermal circuit breaker rated for 200mA at 240V AC and 48V DC, designed for panel mount applications with push-to-reset actuation. This component is classified as Active product status and complies with international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Substitute parts are identified when electrical specifications, mechanical mounting characteristics, and regulatory approvals remain identical across the T11 series.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | T11 |
| Breaker Type | Thermal |
| Current Rating | 200mA |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 48V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Approval Agencies | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4400.0415 are determined by strict equivalence across the following critical parameters:
- Current Rating: 200mA (exact match required)
- Voltage Rating AC: 240V (exact match required)
- Voltage Rating DC: 48V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Number of Poles: 1 (exact match required)
- Series: T11 (exact match required)
- Approval Agencies: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 (exact match required)
- RoHS and REACH Compliance: ROHS3 Compliant, REACH Unaffected (exact match required)
All identified substitute parts meet these criteria without exception.
Parameter Comparison
| Part Number | Manufacturer | Series | Breaker Type | Current Rating | Voltage AC | Voltage DC | Mounting Type | Actuator Type | Poles | Approvals | RoHS Status | REACH Status | Inventory |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4400.0415 | SCHURTER Inc. | T11 | Thermal | 200mA | 240V | 48V | Panel Mount | Push to Reset | 1 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | ROHS3 Compliant | REACH Unaffected | 799 Pcs |
| 4400.0039 | SCHURTER Inc. | T11 | Thermal | 200mA | 240V | 48V | Panel Mount | Push to Reset | 1 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | ROHS3 Compliant | REACH Unaffected | 1042 Pcs |
| 4400.0148 | SCHURTER Inc. | T11 | Thermal | 200mA | 240V | 48V | Panel Mount | Push to Reset | 1 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | ROHS3 Compliant | REACH Unaffected | 923 Pcs |
| 4400.0382 | SCHURTER Inc. | T11 | Thermal | 200mA | 240V | 48V | Panel Mount | Push to Reset | 1 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | ROHS3 Compliant | REACH Unaffected | 890 Pcs |
Engineering Selection Recommendations
All substitute parts—4400.0039, 4400.0148, and 4400.0382—are functionally equivalent to the primary part 4400.0415 based on electrical and mechanical specifications. Each part carries Active product status and maintains identical compliance certifications across CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. All parts are ROHS3 Compliant and REACH Unaffected, meeting current regulatory requirements for electronic component manufacturing and distribution.
Selection among these equivalent parts may be based on inventory availability and packaging considerations, as all electrical and mechanical parameters are identical.
Frequently Asked Questions (FAQ)
Q: Can SCHURTER 4400.0039, 4400.0148, and 4400.0382 be used interchangeably with 4400.0415?
A: Yes. All three parts are parametric equivalents with identical current ratings (200mA), voltage ratings (240V AC, 48V DC), breaker type (thermal), mounting configuration (panel mount), actuation method (push to reset), and regulatory approvals. They are direct substitutes.
Q: Are there differences in compliance certifications between these parts?
A: No. All parts carry identical approvals: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. RoHS and REACH compliance status is identical across all parts.
Q: What factors should determine which substitute part to select?
A: Since electrical and mechanical specifications are identical, selection should be based on inventory availability and packaging requirements. All parts are supplied in bulk packaging.
Q: Is there any difference in product status between the main part and substitutes?
A: No. The main part 4400.0415 and all substitute parts (4400.0039, 4400.0148, 4400.0382) maintain Active product status.
Q: Can these parts be mixed in the same application or assembly?
A: Yes. Since all electrical ratings, mechanical mounting characteristics, and regulatory approvals are identical, these parts are fully interchangeable within the same circuit protection application.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts