SCHURTER 4400.028 Circuit Breaker Thermal 2A 240VAC 48VDC Equivalent & Substitute Parts

Part Overview

The SCHURTER 4400.028 is a thermal circuit breaker rated for 2A at 240V AC and 48V DC, featuring push-to-reset actuation and panel mount configuration. This component is classified as Active product status and carries multiple international approvals including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. Substitute parts are identified when identical electrical and mechanical parameters are maintained across the T11 series, ensuring direct functional equivalence in circuit protection applications.

Substiute Parts

4400.028
SCHURTER Inc.In Stock: 7254400.028 Datasheet
4400.028
Current Part
4400.0002
SCHURTER Inc.In Stock: 12724400.0002 Datasheet
4400.0002
Parametric Equivalent
4400.0035
SCHURTER Inc.In Stock: 11254400.0035 Datasheet
4400.0035
Parametric Equivalent
4400.0037
SCHURTER Inc.In Stock: 11004400.0037 Datasheet
4400.0037
Parametric Equivalent
4400.0047
SCHURTER Inc.In Stock: 11904400.0047 Datasheet
4400.0047
Parametric Equivalent
4400.0189
SCHURTER Inc.In Stock: 10614400.0189 Datasheet
4400.0189
Parametric Equivalent
4400.0193
SCHURTER Inc.In Stock: 10424400.0193 Datasheet
4400.0193
Parametric Equivalent
4400.0711
SCHURTER Inc.In Stock: 9354400.0711 Datasheet
4400.0711
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer SCHURTER Inc.
Series T11
Breaker Type Thermal
Current Rating 2A
Voltage Rating - AC 240V
Voltage Rating - DC 48V
Actuator Type Push to Reset
Number of Poles 1
Mounting Type Panel Mount
Product Status Active
Approval Agency CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected
Packaging Bulk

Substitute Part Grouping Explanation

Substitute parts for the SCHURTER 4400.028 are identified based on strict parametric equivalence within the T11 series. All substitute parts maintain identical specifications across the following critical parameters:

  • Current Rating: 2A
  • Voltage Rating - AC: 240V
  • Voltage Rating - DC: 48V
  • Breaker Type: Thermal
  • Actuator Type: Push to Reset
  • Number of Poles: 1
  • Mounting Type: Panel Mount
  • Series: T11
  • Approval Agency: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
  • RoHS Status: ROHS3 Compliant
  • REACH Status: REACH Unaffected

All identified substitutes are manufactured by SCHURTER Inc. and carry Active product status. Substitution is valid when circuit protection requirements specify these exact electrical and mechanical parameters.

Parameter Comparison

Part Number Current Rating (A) Voltage AC (V) Voltage DC (V) Breaker Type Actuator Type Poles Mounting Series Product Status Inventory (Pcs)
4400.028 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 711
4400.0002 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 1252
4400.0035 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 1070
4400.0037 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 1003
4400.0047 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 1110
4400.0189 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 1008
4400.0193 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 998
4400.0711 2 240 48 Thermal Push to Reset 1 Panel Mount T11 Active 917

Engineering Selection Recommendations

All substitute parts listed maintain identical electrical and mechanical specifications to the primary part 4400.028. Selection among equivalent parts may be based on inventory availability and lead time considerations. All parts carry Active product status and comply with ROHS3 and REACH requirements. Certification compliance is uniform across all listed parts: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Direct substitution is valid for any application requiring a 2A thermal circuit breaker with 240V AC and 48V DC ratings in a single-pole, panel-mount configuration with push-to-reset actuation.

Frequently Asked Questions (FAQ)

Q: Are all listed parts direct substitutes for 4400.028? A: Yes. All parts maintain identical current rating (2A), voltage ratings (240V AC, 48V DC), breaker type (thermal), actuator type (push to reset), pole configuration (1), mounting type (panel mount), and series designation (T11). They are parametrically equivalent.

Q: Do all substitute parts carry the same certifications? A: Yes. All parts listed carry identical approval agency certifications: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.

Q: What is the difference between these part numbers if they are equivalent? A: The part numbers represent different manufacturing batches or internal SCHURTER designations within the T11 series. Electrical and mechanical performance is identical across all listed parts.

Q: Are there any packaging differences between substitute parts? A: All parts are supplied in Bulk packaging. No alternative packaging configurations are provided in this equivalency list.

Q: Can I use these parts interchangeably in my circuit design? A: Yes, provided your circuit design specifies a 2A thermal circuit breaker with 240V AC and 48V DC ratings, single-pole configuration, push-to-reset actuation, and panel mount installation. All listed parts meet these requirements.

Q: What is the inventory status for each part? A: Current inventory levels are: 4400.028 (711 pcs), 4400.0002 (1252 pcs), 4400.0035 (1070 pcs), 4400.0037 (1003 pcs), 4400.0047 (1110 pcs), 4400.0189 (1008 pcs), 4400.0193 (998 pcs), 4400.0711 (917 pcs).

Request Quote (Ships tomorrow)