Request Quote
(Ships tomorrow)
SCHURTER 4400.028 Circuit Breaker Thermal 2A 240VAC 48VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4400.028 is a thermal circuit breaker rated for 2A at 240V AC and 48V DC, featuring push-to-reset actuation and panel mount configuration. This component is classified as Active product status and carries multiple international approvals including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. Substitute parts are identified when identical electrical and mechanical parameters are maintained across the T11 series, ensuring direct functional equivalence in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | T11 |
| Breaker Type | Thermal |
| Current Rating | 2A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 48V |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Mounting Type | Panel Mount |
| Product Status | Active |
| Approval Agency | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4400.028 are identified based on strict parametric equivalence within the T11 series. All substitute parts maintain identical specifications across the following critical parameters:
- Current Rating: 2A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 48V
- Breaker Type: Thermal
- Actuator Type: Push to Reset
- Number of Poles: 1
- Mounting Type: Panel Mount
- Series: T11
- Approval Agency: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
- RoHS Status: ROHS3 Compliant
- REACH Status: REACH Unaffected
All identified substitutes are manufactured by SCHURTER Inc. and carry Active product status. Substitution is valid when circuit protection requirements specify these exact electrical and mechanical parameters.
Parameter Comparison
| Part Number | Current Rating (A) | Voltage AC (V) | Voltage DC (V) | Breaker Type | Actuator Type | Poles | Mounting | Series | Product Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|
| 4400.028 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 711 |
| 4400.0002 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 1252 |
| 4400.0035 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 1070 |
| 4400.0037 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 1003 |
| 4400.0047 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 1110 |
| 4400.0189 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 1008 |
| 4400.0193 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 998 |
| 4400.0711 | 2 | 240 | 48 | Thermal | Push to Reset | 1 | Panel Mount | T11 | Active | 917 |
Engineering Selection Recommendations
All substitute parts listed maintain identical electrical and mechanical specifications to the primary part 4400.028. Selection among equivalent parts may be based on inventory availability and lead time considerations. All parts carry Active product status and comply with ROHS3 and REACH requirements. Certification compliance is uniform across all listed parts: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Direct substitution is valid for any application requiring a 2A thermal circuit breaker with 240V AC and 48V DC ratings in a single-pole, panel-mount configuration with push-to-reset actuation.
Frequently Asked Questions (FAQ)
Q: Are all listed parts direct substitutes for 4400.028? A: Yes. All parts maintain identical current rating (2A), voltage ratings (240V AC, 48V DC), breaker type (thermal), actuator type (push to reset), pole configuration (1), mounting type (panel mount), and series designation (T11). They are parametrically equivalent.
Q: Do all substitute parts carry the same certifications? A: Yes. All parts listed carry identical approval agency certifications: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.
Q: What is the difference between these part numbers if they are equivalent? A: The part numbers represent different manufacturing batches or internal SCHURTER designations within the T11 series. Electrical and mechanical performance is identical across all listed parts.
Q: Are there any packaging differences between substitute parts? A: All parts are supplied in Bulk packaging. No alternative packaging configurations are provided in this equivalency list.
Q: Can I use these parts interchangeably in my circuit design? A: Yes, provided your circuit design specifies a 2A thermal circuit breaker with 240V AC and 48V DC ratings, single-pole configuration, push-to-reset actuation, and panel mount installation. All listed parts meet these requirements.
Q: What is the inventory status for each part? A: Current inventory levels are: 4400.028 (711 pcs), 4400.0002 (1252 pcs), 4400.0035 (1070 pcs), 4400.0037 (1003 pcs), 4400.0047 (1110 pcs), 4400.0189 (1008 pcs), 4400.0193 (998 pcs), 4400.0711 (917 pcs).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts