TE Connectivity AMP Connectors 42698-2 Equivalent & Substitute Parts
Part Overview
The TE Connectivity AMP Connectors 42698-2 is a 0.187" (4.75mm) Quick Connect Female crimp connector designed for 16-20 AWG wire gauges. This non-insulated, angled 90° flag terminal operates as a free-hanging, in-line component within the Faston series. The part is classified as obsolete, necessitating identification of active equivalent alternatives that maintain electrical and mechanical compatibility for continued system support and procurement.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | TE Connectivity AMP Connectors |
| Series | Faston |
| Terminal Type | Angled - 90°, Flag |
| Gender | Female |
| Tab Width | 0.187" (4.75mm) |
| Tab Thickness | 0.020" (0.51mm) |
| Wire Gauge | 16-20 AWG |
| Termination Method | Crimp |
| Insulation Type | Non-Insulated |
| Mounting Type | Free Hanging (In-Line), Right Angle |
| Contact Material | Brass |
| Insulation Diameter Range | 0.100" ~ 0.170" (2.54mm ~ 4.32mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the obsolete 42698-2 is determined by strict equivalence across the following critical parameters:
Electrical Compatibility Parameters:
- Tab width: 0.187" (4.75mm)
- Tab thickness: 0.020" (0.51mm)
- Wire gauge rating: 16-20 AWG
- Gender: Female
- Contact material: Brass
Mechanical Compatibility Parameters:
- Terminal type: Angled 90° flag configuration
- Mounting type: Free hanging, in-line, right angle orientation
- Termination method: Crimp
- Insulation type: Non-insulated
Regulatory & Environmental Parameters:
- RoHS compliance status
- Moisture sensitivity level: 1 (Unlimited)
- ECCN and HTSUS classifications
The substitute part 170141-1 maintains equivalence across all critical electrical and mechanical parameters while offering active product status and current availability.
Parameter Comparison
| Parameter | 42698-2 (Main Part) | 170141-1 (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer | TE Connectivity AMP Connectors | TE Connectivity AMP Connectors | Identical |
| Series | Faston | Faston | Identical |
| Terminal Type | Angled - 90°, Flag | Angled - 90°, Flag | Identical |
| Gender | Female | Female | Identical |
| Tab Width | 0.187" (4.75mm) | 0.187" (4.75mm) | Identical |
| Tab Thickness | 0.020" (0.51mm) | 0.020" (0.51mm) | Identical |
| Wire Gauge | 16-20 AWG | 16-20 AWG | Identical |
| Termination Method | Crimp | Crimp | Identical |
| Insulation Type | Non-Insulated | Non-Insulated | Identical |
| Mounting Type | Free Hanging (In-Line), Right Angle | Free Hanging (In-Line), Right Angle | Identical |
| Contact Material | Brass | Brass | Identical |
| Insulation Diameter Range | 0.100" ~ 0.170" (2.54mm ~ 4.32mm) | 0.110" ~ 0.170" (2.79mm ~ 4.32mm) | Compatible (170141-1 range is subset) |
| RoHS Status | ROHS3 Compliant | RoHS Compliant | Compatible |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Product Status | Obsolete | Active | Substitute is active |
Engineering Selection Recommendations
The TE Connectivity AMP Connectors 170141-1 is the direct equivalent substitute for the obsolete 42698-2. Selection is based on the following engineering criteria:
Electrical & Mechanical Equivalence: Both parts maintain identical tab width (0.187"), tab thickness (0.020"), wire gauge rating (16-20 AWG), terminal orientation (90° angled flag), and mounting configuration (free hanging, in-line, right angle). Contact material (brass) and termination method (crimp) are identical across both parts.
Regulatory Compliance: The 170141-1 maintains RoHS compliance and MSL Level 1 (Unlimited) rating, satisfying environmental and moisture sensitivity requirements equivalent to the original part. Both parts share identical ECCN (EAR99) and HTSUS (8536.90.4000) classifications.
Product Availability: The 170141-1 carries active product status with 1038 pieces in current inventory, ensuring long-term procurement viability and supply chain continuity compared to the obsolete 42698-2.
Insulation Diameter Compatibility: The 170141-1 insulation diameter range (0.110" ~ 0.170") is a compatible subset of the original specification (0.100" ~ 0.170"), accommodating wire gauges within the 16-20 AWG range without functional degradation.
Frequently Asked Questions (FAQ)
Q: Can the 170141-1 directly replace the 42698-2 in existing assemblies?
A: Yes. The 170141-1 maintains identical electrical and mechanical specifications across all critical parameters: tab width, tab thickness, wire gauge rating, terminal type, gender, contact material, and mounting configuration. Direct substitution is supported without circuit or assembly modification.
Q: What is the significance of the insulation diameter range difference?
A: The 170141-1 specifies an insulation diameter range of 0.110" ~ 0.170" compared to the 42698-2 range of 0.100" ~ 0.170". For 16-20 AWG wire applications, the 170141-1 range is fully compatible. Applications requiring wire insulation below 0.110" diameter would require engineering evaluation.
Q: Are there compliance differences between the two parts?
A: Both parts are RoHS compliant and carry MSL Level 1 (Unlimited) ratings. The 42698-2 specifies ROHS3 compliance while the 170141-1 specifies RoHS compliance. Both satisfy current regulatory requirements for the Faston series terminal category.
Q: Why is product status relevant for component selection?
A: The 42698-2 is classified as obsolete, indicating discontinued manufacturing and limited future availability. The 170141-1 is active with current inventory (1038 pieces), ensuring reliable procurement for new designs and ongoing production support.
Q: Are there any mechanical dimension differences that affect installation?
A: The tab length specification for 170141-1 is provided as 0.250" (6.35mm), while the 42698-2 tab length is not specified in available documentation. Both parts maintain identical tab width (0.187") and thickness (0.020"), which are the primary dimensions controlling electrical contact and mechanical fit within mating connectors.
Q: What wire gauges are supported by both parts?
A: Both the 42698-2 and 170141-1 support 16-20 AWG wire gauges. Crimp termination is the required method for both parts. Wire gauge selection must remain within this specified range for proper electrical contact and mechanical retention.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts