3M 3429-1502UG Rectangular Connector Header - Equivalent & Substitute Parts

Part Overview

The 3M 3429-1502UG is a rectangular connector header designed for through-hole, right-angle board-to-board or cable applications with 26 positions at 0.100" (2.54mm) pitch. This component features shrouded 3-wall construction with solder termination and latch lock/eject fastening. The part is classified as obsolete, making equivalent substitutes necessary for ongoing production and maintenance applications requiring compatible 26-position 2.54mm pitch header connectors.

Substiute Parts

3429-1502UG
3MIn Stock: 7933429-1502UG Datasheet
3429-1502UG
Current Part
3429-5002
3MIn Stock: 15163429-5002 Datasheet
3429-5002
MFR Recommended
D3429-5002-AR
3MIn Stock: 1234D3429-5002-AR Datasheet
D3429-5002-AR
MFR Recommended
N3429-5002RB
3MIn Stock: 2315N3429-5002RB Datasheet
N3429-5002RB
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number 3429-1502UG
Manufacturer 3M
Category Rectangular Connectors
Connector Type Header
Contact Type Male Pin
Number of Positions 26
Number of Rows 2
Pitch - Mating 0.100" (2.54mm)
Row Spacing - Mating 0.100" (2.54mm)
Mounting Type Through Hole, Right Angle
Termination Solder
Operating Temperature Range -55°C ~ 105°C
Current Rating 1A
Material Flammability Rating UL94 V-0
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution for the 3429-1502UG is determined by the following critical parameters that must remain constant:

  • Connector Type & Contact Type: Header with male pins
  • Position Count & Pitch: 26 positions at 0.100" (2.54mm) mating pitch
  • Row Configuration: 2 rows with 0.100" (2.54mm) row spacing
  • Mounting Style: Through hole, right angle orientation
  • Termination Method: Solder termination
  • Operating Temperature: -55°C ~ 105°C range
  • Material Flammability: UL94 V-0 rating
  • Insulation Material: Polycyclohexylenedimethylene Terephthalate (PCT), Polyester, Glass Filled

The following substitute parts meet these core requirements:

  • 3429-5002: 3M obsolete series equivalent with enhanced shrouding (4-wall) and increased current rating (1.75A)
  • N3429-5002RB: 3M active series equivalent with 4-wall shrouding, increased current rating (1.75A), and RoHS3 compliance
  • D3429-5002-AR: 3M active D-series equivalent with 4-wall shrouding, increased current rating (1.75A), RoHS3 compliance, and board-to-cable/wire configuration

Parameter Comparison

Parameter 3429-1502UG 3429-5002 N3429-5002RB D3429-5002-AR
Manufacturer 3M 3M 3M 3M
Series 3000 3000 3000 D3000
Product Status Obsolete Obsolete Active Active
Connector Type Header Header Header Header
Contact Type Male Pin Male Pin Male Pin Male Pin
Number of Positions 26 26 26 26
Number of Rows 2 2 2 2
Pitch - Mating 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Row Spacing - Mating 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Mounting Type Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle
Termination Solder Solder Solder Solder
Shrouding Shrouded - 3 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall
Fastening Type Latch Lock/Eject Hooks, Short Push-Pull Push-Pull Push-Pull
Contact Length - Mating 0.240" (6.10mm) 0.240" (6.10mm) 0.240" (6.10mm) 0.240" (6.10mm)
Contact Length - Post 0.112" (2.84mm) 0.112" (2.84mm) 0.112" (2.84mm) 0.112" (2.84mm)
Insulation Height 0.310" (7.87mm) 0.340" (8.64mm) 0.340" (8.64mm) 0.340" (8.64mm)
Contact Shape Square Square Square Square
Contact Finish - Mating Gold Gold Gold Gold
Contact Finish - Post Tin-Lead Tin-Lead Tin Tin
Contact Material Copper Alloy Copper Alloy Copper Alloy Brass
Operating Temperature -55°C ~ 105°C -55°C ~ 105°C -55°C ~ 105°C -55°C ~ 105°C
Current Rating (Amps) 1A 1.75A 1.75A 1.75A
Material Flammability Rating UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0
RoHS Status RoHS non-compliant RoHS non-compliant RoHS3 Compliant RoHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

For Active Production (Recommended):

N3429-5002RB and D3429-5002-AR are the preferred substitutes as both maintain active product status with RoHS3 compliance. N3429-5002RB is suitable for board-to-board or cable applications, while D3429-5002-AR is optimized for board-to-cable/wire configurations. Both provide enhanced current rating (1.75A versus 1A) and improved shrouding (4-wall versus 3-wall).

For Legacy System Maintenance:

3429-5002 provides functional equivalence with identical series designation but remains obsolete. This part is suitable only when active alternatives cannot meet specific legacy system requirements.

Compliance Considerations:

The original 3429-1502UG is RoHS non-compliant. Designs requiring RoHS3 compliance must transition to N3429-5002RB or D3429-5002-AR. Both active alternatives maintain identical electrical and mechanical compatibility while meeting current regulatory requirements.

Frequently Asked Questions (FAQ)

Q: Can N3429-5002RB directly replace 3429-1502UG in existing designs?

A: Yes. Both parts maintain identical connector type, position count (26), pitch (0.100"/2.54mm), row configuration, mounting style (through-hole right angle), and operating temperature range (-55°C ~ 105°C). The N3429-5002RB provides enhanced current rating (1.75A) and improved shrouding (4-wall), making it functionally superior for the same footprint and mating interface.

Q: What is the difference between N3429-5002RB and D3429-5002-AR?

A: Both are active 3M products with identical electrical specifications and current ratings. The primary difference is application style: N3429-5002RB supports board-to-board or cable connections, while D3429-5002-AR is configured for board-to-cable/wire applications. Contact material also differs (copper alloy versus brass). Selection depends on the specific mating interface required.

Q: Are there packaging differences between the substitute parts?

A: Yes. 3429-5002 and N3429-5002RB are supplied in bulk packaging, while D3429-5002-AR is supplied in tray packaging. Packaging selection should align with production volume and handling requirements.

Q: Does the increased insulation height (0.340" versus 0.310") affect PCB layout?

A: The 0.030" (0.77mm) increase in insulation height must be verified against PCB clearance requirements and adjacent component placement. This dimension change is consistent across all substitute parts and should be evaluated during design transition.

Q: What is the significance of the fastening type change from latch lock/eject hooks to push-pull?

A: The fastening mechanism differs between the original and substitutes. The 3429-1502UG uses short latch lock/eject hooks, while substitutes employ push-pull fastening. This affects mating and unmating procedures and must be considered for connector handling in the application.

Q: Is RoHS3 compliance mandatory for my application?

A: RoHS3 compliance is required for products sold in the European Union and many other regulated markets. N3429-5002RB and D3429-5002-AR meet RoHS3 requirements, while 3429-1502UG and 3429-5002 do not. Verify regulatory requirements for your target markets before part selection.

Request Quote (Ships tomorrow)