3M 3425-6050 Equivalent & Substitute Parts

Part Overview

The 3M 3425-6050 is a 50-position rectangular receptacle connector with IDC (Insulation Displacement Contact) termination, designed for ribbon cable applications with wire gauges from 26-30 AWG. This connector features gold-plated contacts, feed-through capability, and strain relief, making it suitable for high-density interconnect applications requiring reliable signal transmission. The part is currently active in production with full RoHS3 compliance and unlimited moisture sensitivity rating. Substitute parts are identified when equivalent electrical and mechanical parameters are maintained across manufacturers while meeting the same compliance and performance standards.

Substiute Parts

3425-6050
3MIn Stock: 12533425-6050 Datasheet
3425-6050
Current Part
09185506813
HARTINGIn Stock: 134809185506813 Datasheet
09185506813
MFR Recommended
09185507813
HARTINGIn Stock: 88109185507813 Datasheet
09185507813
MFR Recommended
1-1658620-0
TE Connectivity AMP ConnectorsIn Stock: 23141-1658620-0 Datasheet
1-1658620-0
MFR Recommended
66900-050LF
Amphenol ICC (FCI)In Stock: 126466900-050LF Datasheet
66900-050LF
MFR Recommended
71600-250LF
Amphenol ICC (FCI)In Stock: 93471600-250LF Datasheet
71600-250LF
MFR Recommended

Key Parameters

Parameter Specification
Connector Type Receptacle
Number of Positions 50
Pitch 0.100" (2.54mm)
Number of Rows 2
Row Spacing 0.100" (2.54mm)
Cable Termination IDC
Wire Type Ribbon Cable
Wire Gauge 26-30 AWG
Contact Finish Gold
Mounting Type Free Hanging (In-Line)
Features Feed Through, Strain Relief
RoHS Status ROHS3 Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the 3M 3425-6050 is determined by the following critical parameters:

Primary Matching Criteria:

  • Connector type: Receptacle
  • Number of positions: 50
  • Pitch: 0.100" (2.54mm)
  • Number of rows: 2
  • Row spacing: 0.100" (2.54mm)
  • Cable termination: IDC
  • Wire type: Ribbon Cable
  • Contact finish: Gold
  • Mounting type: Free Hanging (In-Line)

Secondary Compatibility Parameters:

  • Wire gauge range: 26-30 AWG (substitutes may support 26-28 AWG or 28-30 AWG subsets)
  • Contact type: Female Socket or Forked contacts
  • Features: Feed Through capability required; Strain Relief and Polarizing Key are compatible enhancements
  • Compliance: RoHS3 compliance required; MSL 1 rating required

All identified substitute parts maintain the core electrical and mechanical interface specifications, ensuring mechanical fit and electrical performance compatibility with applications designed for the 3M 3425-6050.

Parameter Comparison

Parameter 3M 3425-6050 HARTING 09185506813 HARTING 09185507813 TE Connectivity 1-1658620-0 Amphenol ICC 66900-050LF Amphenol ICC 71600-250LF
Manufacturer 3M HARTING HARTING TE Connectivity AMP Connectors Amphenol ICC (FCI) Amphenol ICC (FCI)
Number of Positions 50 50 50 50 50 50
Pitch 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Number of Rows 2 2 2 2 2 2
Row Spacing 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Wire Gauge 26-30 AWG 26-28 AWG 26-28 AWG 26-28 AWG 28-30 AWG 28-30 AWG
Cable Termination IDC IDC IDC IDC IDC IDC
Wire Type Ribbon Cable Ribbon Cable Ribbon Cable Ribbon Cable Ribbon Cable Ribbon Cable
Contact Type Female Socket Female Socket Female Socket Forked Female Socket Female Socket
Contact Finish Gold Gold Gold Gold Gold, GXT™ Gold
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line)
Features Feed Through, Strain Relief Feed Through, Polarizing Key, Strain Relief Feed Through, Polarizing Key, Strain Relief Feed Through Feed Through, Strain Relief Feed Through, Polarizing Key, Strain Relief
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant RoHS Compliant RoHS Compliant
MSL Rating 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
Product Status Active Active Active Active Active Active

Engineering Selection Recommendations

All identified substitute parts maintain active product status and meet or exceed the compliance requirements of the 3M 3425-6050. Selection among substitutes should be based on wire gauge compatibility with the specific application:

For applications using 26-30 AWG ribbon cable: The 3M 3425-6050 provides full wire gauge coverage. Substitutes with 26-28 AWG or 28-30 AWG ranges are compatible only when the actual ribbon cable gauge falls within the substitute's specified range.

HARTING 09185506813 and 09185507813: Both support 26-28 AWG wire gauge and include polarizing key features. ROHS3 compliance is confirmed. These parts are suitable for applications requiring wire gauges within the 26-28 AWG range.

TE Connectivity 1-1658620-0: Supports 26-28 AWG wire gauge with forked contact type. ROHS3 compliance is confirmed. This part is suitable for applications requiring wire gauges within the 26-28 AWG range and compatible with forked contact interfaces.

Amphenol ICC 66900-050LF and 71600-250LF: Both support 28-30 AWG wire gauge. RoHS compliance is confirmed. The 71600-250LF includes a polarizing key feature. These parts are suitable for applications requiring wire gauges within the 28-30 AWG range.

All substitute parts maintain the same pitch, row configuration, IDC termination method, and free-hanging mounting type as the original part, ensuring mechanical and electrical compatibility within their respective wire gauge specifications.

Frequently Asked Questions (FAQ)

Q: Can I use a substitute part with a different wire gauge range than my original application?

A: Wire gauge compatibility is determined by the actual ribbon cable used in your application. If your ribbon cable is 28 AWG, you may use any substitute supporting 28 AWG, including those rated for 26-28 AWG or 28-30 AWG ranges. If your ribbon cable is 26 AWG, you must use a substitute supporting 26 AWG, such as the HARTING or TE Connectivity options. The 3M 3425-6050 supports the full 26-30 AWG range; substitutes with narrower ranges are compatible only when the actual cable gauge falls within that range.

Q: What is the difference between female socket and forked contact types?

A: Both contact types are designed for IDC termination into ribbon cable. Female socket contacts and forked contacts provide different mechanical engagement profiles with mating connectors. The TE Connectivity 1-1658620-0 uses forked contacts, while other substitutes use female socket contacts. Selection depends on the mating connector type specified in your application.

Q: Do all substitute parts include strain relief?

A: The 3M 3425-6050, Amphenol ICC 66900-050LF, and Amphenol ICC 71600-250LF all include strain relief. The HARTING 09185506813 and 09185507813 do not list strain relief in their feature set. The TE Connectivity 1-1658620-0 does not include strain relief. If strain relief is required for your application, select from the 3M original or the Amphenol ICC options.

Q: Are polarizing keys available on all substitute parts?

A: Polarizing keys are included on HARTING 09185506813, HARTING 09185507813, and Amphenol ICC 71600-250LF. The 3M 3425-6050, TE Connectivity 1-1658620-0, and Amphenol ICC 66900-050LF do not include polarizing keys. Polarizing keys provide keyed mating to prevent incorrect connector orientation.

Q: What is the difference between ROHS3 and RoHS compliance?

A: ROHS3 compliance indicates adherence to the most current RoHS directive requirements. The 3M 3425-6050 and all HARTING and TE Connectivity substitutes are ROHS3 compliant. The Amphenol ICC 66900-050LF and 71600-250LF are RoHS compliant but not specifically designated as ROHS3. Both compliance levels meet environmental and hazardous substance restrictions; ROHS3 represents the latest regulatory standard.

Q: Can I mix substitute parts from different manufacturers in the same application?

A: All substitute parts maintain identical pitch, row configuration, and mounting specifications, allowing them to be used interchangeably within the same connector interface. However, wire gauge compatibility must be verified for each part based on your actual ribbon cable specification. Mixing parts with different wire gauge ratings in a single application is not recommended unless each part is used with ribbon cable matching its specified gauge range.

Request Quote (Ships tomorrow)