3M 3314-6202 Rectangular Connector Header - Equivalent & Substitute Parts

Part Overview

The 3M 3314-6202 is a vertical through-hole rectangular connector header with 14 positions at 2.54mm pitch, featuring shrouded 4-wall design and solder termination. This part is classified as obsolete. Equivalent and substitute parts are necessary to maintain design compatibility in applications where the original component is no longer available from inventory or production has been discontinued.

Substiute Parts

3314-6202
3MIn Stock: 9813314-6202 Datasheet
3314-6202
Current Part
3314-6002
3MIn Stock: 6863314-6002 Datasheet
3314-6002
MFR Recommended
N3314-6002RB
3MIn Stock: 2213N3314-6002RB Datasheet
N3314-6002RB
MFR Recommended
09185145329
HARTINGIn Stock: 115809185145329 Datasheet
09185145329
MFR Recommended
09185145902
HARTINGIn Stock: 111209185145902 Datasheet
09185145902
MFR Recommended
09185145904
HARTINGIn Stock: 122509185145904 Datasheet
09185145904
MFR Recommended
09185146321
HARTINGIn Stock: 75609185146321 Datasheet
09185146321
MFR Recommended
09185146902
HARTINGIn Stock: 92209185146902 Datasheet
09185146902
MFR Recommended
09185146904
HARTINGIn Stock: 149609185146904 Datasheet
09185146904
MFR Recommended
09185147321
HARTINGIn Stock: 94409185147321 Datasheet
09185147321
MFR Recommended
09185147902
HARTINGIn Stock: 97609185147902 Datasheet
09185147902
MFR Recommended
09185147904
HARTINGIn Stock: 119609185147904 Datasheet
09185147904
MFR Recommended
09185165322
HARTINGIn Stock: 104409185165322 Datasheet
09185165322
MFR Recommended
09185167901
HARTINGIn Stock: 81809185167901 Datasheet
09185167901
MFR Recommended
09195145904
HARTINGIn Stock: 114409195145904 Datasheet
09195145904
MFR Recommended
09195146904
HARTINGIn Stock: 98809195146904 Datasheet
09195146904
MFR Recommended
499374-2
TE Connectivity AMP ConnectorsIn Stock: 811499374-2 Datasheet
499374-2
MFR Recommended
499910-2
TE Connectivity AMP ConnectorsIn Stock: 801499910-2 Datasheet
499910-2
MFR Recommended
5499160-2
TE Connectivity AMP ConnectorsIn Stock: 12525499160-2 Datasheet
5499160-2
MFR Recommended
5499374-2
TE Connectivity AMP ConnectorsIn Stock: 9635499374-2 Datasheet
5499374-2
MFR Recommended
5499910-2
TE Connectivity AMP ConnectorsIn Stock: 12015499910-2 Datasheet
5499910-2
MFR Recommended
71918-214LF
Amphenol ICC (FCI)In Stock: 143271918-214LF Datasheet
71918-214LF
MFR Recommended
CWN-551-14-0021
CW IndustriesIn Stock: 916CWN-551-14-0021 Datasheet
CWN-551-14-0021
MFR Recommended

Key Parameters

Parameter Value
Connector Type Header
Contact Type Male Pin
Number of Positions 14
Number of Rows 2
Pitch - Mating 0.100" (2.54mm)
Row Spacing - Mating 0.100" (2.54mm)
Mounting Type Through Hole
Termination Solder
Shrouding Shrouded - 4 Wall
Operating Temperature -55°C ~ 105°C
Current Rating 1A
Material Flammability Rating UL94 V-0
RoHS Status RoHS non-compliant

Substitute Part Grouping Explanation

Substitute parts for the 3M 3314-6202 are grouped based on strict electrical and mechanical compatibility criteria. The primary substitution parameters are:

  • Connector type (Header)
  • Contact type (Male Pin)
  • Number of positions (14) and rows (2)
  • Pitch spacing (0.100" / 2.54mm mating and row spacing)
  • Mounting type (Through Hole)
  • Termination method (Solder)
  • Shrouding configuration (Shrouded - 4 Wall)
  • Material flammability rating (UL94 V-0)

Substitutes are divided into two categories:

Category 1: Direct Vertical Substitutes - Parts maintaining identical mounting orientation (vertical through-hole) with compatible fastening mechanisms and contact geometries.

Category 2: Right-Angle Variants - Parts with right-angle mounting orientation, suitable only for applications where board layout permits this configuration change.

Parameter Comparison

Manufacturer Part Number Manufacturer Connector Type Positions Pitch (mm) Mounting Type Fastening Type Operating Temp (°C) Current Rating (A) Product Status RoHS Status
3314-6202 3M Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Short -55 ~ 105 1 Obsolete Non-compliant
3314-6002 3M Header 14 (2x7) 2.54 Through Hole Push-Pull -55 ~ 105 1 Obsolete Non-compliant
N3314-6002RB 3M Header 14 (2x7) 2.54 Through Hole Push-Pull -55 ~ 105 1.75 Active Compliant
09185145329 HARTING Header 14 (2x7) 2.54 Through Hole Push-Pull Not specified Not specified Active ROHS3 Compliant
09185145902 HARTING Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Long -55 ~ 125 Not specified Active ROHS3 Compliant
09185145904 HARTING Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Long -55 ~ 125 Not specified Active ROHS3 Compliant
09185146321 HARTING Header 14 (2x7) 2.54 Through Hole, Right Angle Latch Holder -55 ~ 125 Not specified Active ROHS3 Compliant
09185146902 HARTING Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Long -55 ~ 125 Not specified Active ROHS3 Compliant
09185146904 HARTING Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Long -55 ~ 125 Not specified Active ROHS3 Compliant
09185147321 HARTING Header 14 (2x7) 2.54 Through Hole, Right Angle Latch Holder -55 ~ 125 Not specified Active ROHS3 Compliant
09185147902 HARTING Header 14 (2x7) 2.54 Through Hole Latch Lock/Eject Hooks, Long -55 ~ 125 Not specified Active ROHS3 Compliant

Engineering Selection Recommendations

Primary Recommendation: N3314-6002RB (3M)

The N3314-6002RB is the preferred substitute for the 3314-6202. This part maintains 3M manufacturing continuity, is currently in active production status, and holds RoHS compliance certification. The increased current rating of 1.75A provides enhanced electrical capacity over the original 1A specification. Operating temperature range remains -55°C to 105°C, maintaining thermal compatibility with the original design envelope.

Secondary Recommendations: HARTING SEK Series (09185145902, 09185145904, 09185146902, 09185146904, 09185147902)

HARTING SEK series connectors provide active production alternatives with ROHS3 compliance and extended operating temperature range to -55°C to 125°C. These parts maintain the 14-position, 2.54mm pitch configuration with shrouded 4-wall design. Fastening mechanisms differ from the original (Latch Lock/Eject Hooks, Long versus Short), requiring mechanical compatibility assessment for mating connector interfaces.

Right-Angle Variants: 09185146321, 09185147321 (HARTING)

Right-angle mounting options are available from HARTING (09185146321, 09185147321) for applications requiring perpendicular board orientation. These parts are suitable only when board layout permits right-angle connector mounting and are not direct mechanical substitutes for vertical mounting applications.

Compliance Consideration:

The original 3314-6202 is RoHS non-compliant. All recommended substitutes (N3314-6002RB and HARTING SEK series) are RoHS compliant or ROHS3 compliant, supporting modern regulatory requirements in manufacturing and procurement.

Frequently Asked Questions (FAQ)

Q: Can the N3314-6002RB directly replace the 3314-6202 in existing designs?

A: Yes. Both parts share identical pitch spacing (2.54mm), position count (14), row configuration (2x7), shrouding (4-wall), and through-hole mounting. The fastening mechanism differs (Push-Pull versus Latch Lock/Eject Hooks, Short), but this affects only the mating connector interface, not the header itself. Mating connectors must be compatible with the Push-Pull fastening type.

Q: What is the difference between the HARTING parts with "Long" versus "Short" fastening hooks?

A: Fastening hook length affects the mechanical engagement depth with mating connectors. "Long" hooks provide greater engagement depth and are typically used in applications requiring higher mechanical retention force. The original 3314-6202 uses "Short" hooks. HARTING substitutes with "Long" hooks require mating connectors designed for this longer engagement profile.

Q: Are the right-angle HARTING parts (09185146321, 09185147321) compatible with vertical mounting applications?

A: No. Right-angle parts are designed for perpendicular board mounting and cannot be used in applications requiring vertical connector orientation. These are suitable only for designs where board layout permits right-angle connector placement.

Q: What is the significance of the operating temperature difference between the original part (-55°C to 105°C) and HARTING substitutes (-55°C to 125°C)?

A: The extended upper temperature limit of HARTING parts provides additional thermal margin for high-temperature applications. If the original design operates within -55°C to 105°C, HARTING substitutes remain fully compatible. The extended range does not affect compatibility in standard temperature environments.

Q: Does the increased current rating of N3314-6002RB (1.75A versus 1A) affect compatibility?

A: No. Higher current rating indicates increased electrical capacity and does not affect mechanical or electrical compatibility. The part remains suitable for applications designed for 1A operation and provides additional capacity margin for future design iterations.

Q: Are all substitute parts available in the same packaging as the original 3314-6202?

A: Substitute parts are available in bulk packaging. Original packaging specifications should be confirmed with the supplier for specific procurement requirements.

Q: What compliance certifications apply to these substitute parts?

A: The N3314-6002RB holds RoHS compliance. HARTING SEK series parts (09185145329, 09185145902, 09185145904, 09185146321, 09185146902, 09185146904, 09185147321, 09185147902) hold ROHS3 compliance and REACH Unaffected status. All parts maintain UL94 V-0 material flammability rating.

Request Quote (Ships tomorrow)