2G25UM 25A Circuit Breaker Equivalent & Substitute Parts

Part Overview

The 2G25UM is a thermal magnetic circuit breaker manufactured by Altech Corporation, rated for 25A at 480V AC and 80V DC. This DIN rail-mounted breaker is part of the V-EA series and maintains active product status with full CSA and UL508 approvals. Equivalent substitute parts are available within the same series to accommodate supply chain requirements, design variations, or regional availability constraints.

Substiute Parts

2G25UM
Altech CorporationIn Stock: 12382G25UM Datasheet
2G25UM
Current Part
2B25UM
Altech CorporationIn Stock: 8412B25UM Datasheet
2B25UM
Parametric Equivalent
2C25UM
Altech CorporationIn Stock: 7782C25UM Datasheet
2C25UM
Parametric Equivalent
2D25UM
Altech CorporationIn Stock: 7582D25UM Datasheet
2D25UM
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer Altech Corporation
Series V-EA
Breaker Type Thermal Magnetic
Current Rating 25A
Voltage Rating - AC 480V
Voltage Rating - DC 80V
Mounting Type DIN Rail
Actuator Type Lever
Number of Poles 2
Approval Agencies CSA, UL508
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

The 2G25UM circuit breaker has three parametric equivalents within the Altech V-EA series: 2B25UM, 2C25UM, and 2D25UM. These parts are interchangeable based on the following criteria:

All substitute parts share identical electrical and mechanical specifications:

  • Current rating: 25A
  • Voltage ratings: 480V AC / 80V DC
  • Breaker type: Thermal Magnetic
  • Mounting: DIN Rail
  • Actuator: Lever
  • Pole configuration: 2-pole
  • Series designation: V-EA
  • Compliance: ROHS3 Compliant, REACH Unaffected

The primary distinction between these parts lies in their thermal-magnetic trip characteristic designations (G, B, C, D), which define the specific trip curve behavior. These designations allow selection based on application-specific load characteristics and protection requirements while maintaining full electrical and mechanical compatibility.

Parameter Comparison

Part Number Manufacturer Current Rating Voltage AC Voltage DC Breaker Type Mounting Poles Approval Agencies Inventory Status
2G25UM Altech Corporation 25A 480V 80V Thermal Magnetic DIN Rail 2 CSA, UL508 1135 Pcs
2B25UM Altech Corporation 25A 480V 80V Thermal Magnetic DIN Rail 2 CSA, UL508, VDE 794 Pcs
2C25UM Altech Corporation 25A 480V 80V Thermal Magnetic DIN Rail 2 CSA, UL508, VDE 744 Pcs
2D25UM Altech Corporation 25A 480V 80V Thermal Magnetic DIN Rail 2 CSA, UL508, VDE 745 Pcs

Engineering Selection Recommendations

All four parts (2G25UM, 2B25UM, 2C25UM, 2D25UM) are active products with full compliance certifications. The 2B25UM, 2C25UM, and 2D25UM variants include additional VDE approval beyond the base CSA and UL508 certifications present on the 2G25UM.

Selection between these equivalents should be based on:

  • Application-specific trip curve requirements (G, B, C, or D characteristic)
  • Regional compliance requirements (VDE certification availability)
  • Supply chain and inventory availability
  • System design specifications for load protection behavior

All parts maintain identical electrical ratings, mechanical form factors, and RoHS3 compliance status, ensuring direct substitution capability within the specified parameters.

Frequently Asked Questions (FAQ)

Q: Are 2B25UM, 2C25UM, and 2D25UM direct substitutes for 2G25UM?

A: Yes, within the constraints of application-specific trip curve requirements. All parts share identical current ratings (25A), voltage ratings (480V AC / 80V DC), mounting type (DIN Rail), pole configuration (2-pole), and breaker technology (Thermal Magnetic). The letter designations (G, B, C, D) indicate different thermal-magnetic trip characteristics. Substitution is valid when the application permits the alternative trip curve.

Q: What is the difference between the G, B, C, and D designations?

A: These letters denote distinct thermal-magnetic trip curve characteristics that define the breaker's response to overcurrent conditions. Each characteristic is engineered for specific load types and protection requirements. Selection depends on the protected circuit's load profile and protection strategy.

Q: Do all substitute parts have the same certifications?

A: The 2G25UM carries CSA and UL508 approvals. The 2B25UM, 2C25UM, and 2D25UM variants include CSA, UL508, and VDE approvals. If VDE certification is required for your application, the B, C, or D variants are specified options.

Q: Are these parts compatible with the same DIN rail systems?

A: Yes. All four parts use identical DIN rail mounting specifications and lever actuator configurations, ensuring mechanical compatibility with standard DIN rail enclosures and control panels.

Q: What is the packaging format for these parts?

A: All parts are supplied in bulk packaging format.

Q: Are these parts RoHS compliant?

A: Yes. All four parts are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements.

Request Quote (Ships tomorrow)