Phoenix Contact 2967934 SSR Relay SPST-NO Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 2967934 is a solid-state relay (SSR) module configured as SPST-NO (Single Pole Single Throw - Normally Open) with a 0.75A load capacity and AC output type. This component is designed for DIN rail mounting and operates across a voltage range of 24V to 253V on the load side, with 230VAC or 220VDC input control voltage.
The 2967934 is classified as obsolete. Locating equivalent or substitute components is necessary to maintain system functionality and ensure continued availability for new installations or replacements in existing applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2967934 |
| Manufacturer | Phoenix Contact |
| Series | PLC |
| Circuit Configuration | SPST-NO (1 Form A) |
| Output Type | AC |
| Voltage - Input | 230VAC, 220VDC |
| Voltage - Load | 24 V ~ 253 V |
| Load Current | 0.75 A |
| Mounting Type | DIN Rail |
| Termination Style | Spring Terminal |
| Package / Case | Module |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution of the Phoenix Contact 2967934 is determined by strict equivalence across the following critical parameters:
- Circuit Configuration: Must be SPST-NO (1 Form A) to maintain identical switching functionality
- Output Type: Must be AC to ensure compatibility with the load circuit
- Voltage - Load Range: Must support 24 V ~ 253 V to cover the full operating envelope
- Load Current: Must support minimum 0.75 A (750 mA) capacity
- Mounting Type: Must be DIN Rail to fit existing mechanical installations
- Termination Style: Must be Spring Terminal for connection compatibility
- Input Voltage: Must accept 230VAC or 220VDC control signals
The Phoenix Contact 2900374 meets all substitution criteria. It is an active product in the PLC-OPT series with identical electrical specifications and mechanical form factor.
Parameter Comparison
| Parameter | 2967934 (Main Part) | 2900374 (Substitute) | Match |
|---|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact | Yes |
| Circuit Configuration | SPST-NO (1 Form A) | SPST-NO (1 Form A) | Yes |
| Output Type | AC | AC | Yes |
| Voltage - Input | 230VAC, 220VDC | 230VAC/DC | Yes |
| Voltage - Load | 24 V ~ 253 V | 24 V ~ 253 V | Yes |
| Load Current | 0.75 A | 750 mA | Yes |
| Mounting Type | DIN Rail | DIN Rail | Yes |
| Termination Style | Spring Terminal | Spring Terminal | Yes |
| Package / Case | Module | Module | Yes |
| RoHS Status | RoHS Compliant | RoHS Compliant | Yes |
| Product Status | Obsolete | Active | Active Status Preferred |
Engineering Selection Recommendations
The Phoenix Contact 2900374 is the direct substitute for the 2967934. Both components are RoHS compliant and carry identical electrical and mechanical specifications. The 2900374 holds active product status, ensuring ongoing availability and support from the manufacturer. The transition from the PLC series (2967934) to the PLC-OPT series (2900374) represents a product line evolution while maintaining full functional equivalence.
For applications currently using the 2967934, the 2900374 provides a direct replacement without circuit redesign or mechanical modification requirements.
Frequently Asked Questions (FAQ)
Q: Can the 2900374 directly replace the 2967934 in existing installations?
A: Yes. Both components share identical electrical specifications (SPST-NO configuration, AC output, 24–253V load voltage, 0.75A/750mA current rating) and mechanical form factor (DIN rail mounting, spring terminals). No circuit or mechanical changes are required.
Q: What is the difference between the PLC and PLC-OPT series?
A: The PLC-OPT series represents an active product line evolution. The 2900374 (PLC-OPT) supersedes the 2967934 (PLC) with equivalent performance and specifications. The PLC-OPT designation indicates an optimized or updated variant within the Phoenix Contact solid-state relay portfolio.
Q: Are both parts RoHS compliant?
A: Yes. Both the 2967934 and 2900374 are RoHS compliant, meeting environmental and regulatory requirements for electronic components.
Q: Does the 2900374 support the same input voltage as the 2967934?
A: Yes. The 2900374 accepts 230VAC/DC input control voltage, covering the 230VAC and 220VDC specifications of the 2967934.
Q: What is the inventory status of these parts?
A: The 2967934 (obsolete) has 732 pieces in stock. The 2900374 (active) has 631 pieces in stock. For new designs or long-term applications, the 2900374 is recommended due to its active product status.
Q: Are the termination methods identical?
A: Yes. Both components use spring terminal termination, ensuring compatibility with existing wiring and connection infrastructure.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts