Phoenix Contact 2967594 SSR Relay SPST-NO 100MA 3-48V Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 2967594 is a solid-state relay (SSR) module configured as SPST-NO (1 Form A) with a 100 mA load capacity and 3-48V DC output range. This component is classified as obsolete, making identification of equivalent and substitute parts essential for system maintenance, repair, and redesign applications. The module features DIN rail mounting and spring terminal connections, designed for industrial control applications within the PLC series.

Substiute Parts

2967594
Phoenix ContactIn Stock: 8022967594 Datasheet
2967594
Current Part
2900361
Phoenix ContactIn Stock: 10022900361 Datasheet
2900361
Direct

Key Parameters

Parameter Specification
Manufacturer Phoenix Contact
Circuit Configuration SPST-NO (1 Form A)
Output Type DC
Voltage - Input 230VAC, 220VDC
Voltage - Load 3 V ~ 48 V
Load Current 100 mA
Mounting Type DIN Rail
Termination Style Spring Terminal
Package / Case Module
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the Phoenix Contact 2967594 is determined by strict equivalence across the following critical parameters:

  • Circuit configuration: SPST-NO (1 Form A) topology
  • Output type: DC switching capability
  • Input voltage range: 230VAC/DC compatibility
  • Load voltage range: 3-48V DC operation
  • Load current rating: 100 mA minimum capacity
  • Mounting interface: DIN rail compatibility
  • Termination method: Spring terminal connections
  • Package form: Module-level assembly

The Phoenix Contact 2900361 satisfies all substitution criteria as a direct equivalent within the Phoenix Contact product family, with the distinction of active product status and updated compliance certifications.

Parameter Comparison

Parameter 2967594 (Main Part) 2900361 (Substitute)
Manufacturer Phoenix Contact Phoenix Contact
Series PLC PLC-OPT
Product Status Obsolete Active
Circuit Configuration SPST-NO (1 Form A) SPST-NO (1 Form A)
Output Type DC DC
Voltage - Input 230VAC, 220VDC 230VAC/DC
Voltage - Load 3 V ~ 48 V 3 V ~ 48 V
Load Current 100 mA 100 mA
Mounting Type DIN Rail DIN Rail
Termination Style Spring Terminal Spring Terminal
Package / Case Module Module
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8536.49.0055 8536.49.0055

Engineering Selection Recommendations

The Phoenix Contact 2900361 is the direct substitute for the obsolete 2967594. Both components maintain identical electrical and mechanical specifications across all critical parameters: SPST-NO circuit topology, 100 mA load current, 3-48V DC output range, and DIN rail mounting with spring terminals.

The 2900361 offers the advantage of active product status, ensuring continued availability and supply chain support. The component carries ROHS3 compliance, representing current regulatory alignment. Both parts share identical ECCN and HTSUS classifications, confirming regulatory equivalence for export and tariff purposes.

The transition from the PLC series (2967594) to the PLC-OPT series (2900361) reflects Phoenix Contact's product line evolution while maintaining full functional compatibility for existing applications.

Frequently Asked Questions (FAQ)

Q: Can the Phoenix Contact 2900361 directly replace the 2967594 in existing installations?

A: Yes. Both components share identical electrical specifications (SPST-NO circuit, 100 mA load current, 3-48V DC output), identical input voltage compatibility (230VAC/DC), and identical mechanical interfaces (DIN rail mounting, spring terminals). No circuit modifications are required.

Q: What is the significance of the series designation change from PLC to PLC-OPT?

A: The series designation reflects Phoenix Contact's product line organization. The PLC-OPT designation indicates an optimized variant within the same functional family. All electrical and mechanical parameters remain equivalent.

Q: Are there compliance differences between the two parts?

A: Both components are RoHS compliant. The 2900361 carries ROHS3 certification, representing current regulatory standards. The 2967594 carries RoHS compliance. Both share identical ECCN (EAR99) and HTSUS (8536.49.0055) classifications.

Q: Why is the 2967594 listed as obsolete?

A: Obsolete status indicates the part is no longer in active production. The 2900361 represents the current production equivalent, ensuring long-term supply availability and support.

Q: Are the packaging formats compatible?

A: The 2967594 is supplied in standard packaging, while the 2900361 is supplied in bulk packaging. Both maintain identical module form factors and DIN rail mounting interfaces. Packaging format does not affect functional compatibility.

Q: What is the REACH status of these components?

A: The 2900361 is REACH Affected. The 2967594 REACH status is not specified in the provided data. For applications requiring REACH compliance documentation, the 2900361 is the appropriate selection.