Phoenix Contact 2967484 SSR Relay SPST-NO 3A 3-33V Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 2967484 is a solid-state relay (SSR) module configured as SPST-NO (Single Pole Single Throw - Normally Open) with a 3A load capacity and 3-33V DC output range. This component is classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance, repair, and redesign applications. The part operates with 120VAC/DC input control voltage and employs spring terminal connections for DIN rail mounting.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2967484 |
| Manufacturer | Phoenix Contact |
| Series | PLC-OSP |
| Product Status | Obsolete |
| Circuit Configuration | SPST-NO (1 Form A) |
| Output Type | DC |
| Voltage - Input | 120VAC/DC |
| Voltage - Load | 3 V ~ 33 V |
| Load Current | 3 A |
| Mounting Type | DIN Rail |
| Termination Style | Spring Terminal |
| Package / Case | Module |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 2967484 is determined by strict equivalence across the following critical parameters:
- Circuit Configuration: Must be SPST-NO (1 Form A) to maintain identical switching topology
- Output Type: Must be DC to ensure compatible load switching characteristics
- Voltage - Input: Must be 120VAC/DC to match control signal requirements
- Voltage - Load: Must support 3 V ~ 33 V range for output switching
- Load Current: Must be rated for minimum 3 A continuous operation
- Mounting Type: Must be DIN Rail to ensure mechanical compatibility with existing installations
- Termination Style: Must be Spring Terminal for connection compatibility
- Package / Case: Must be Module format for form factor equivalence
- RoHS Status: Must be RoHS Compliant to meet regulatory requirements
The Phoenix Contact 2900367 meets all substitution criteria and is classified as an active product, providing a direct functional replacement for the obsolete 2967484.
Parameter Comparison
| Parameter | 2967484 (Main Part) | 2900367 (Substitute) | Match Status |
|---|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact | Identical |
| Circuit Configuration | SPST-NO (1 Form A) | SPST-NO (1 Form A) | Identical |
| Output Type | DC | DC | Identical |
| Voltage - Input | 120VAC/DC | 120VAC/DC | Identical |
| Voltage - Load | 3 V ~ 33 V | 3 V ~ 33 V | Identical |
| Load Current | 3 A | 3 A | Identical |
| Mounting Type | DIN Rail | DIN Rail | Identical |
| Termination Style | Spring Terminal | Spring Terminal | Identical |
| Package / Case | Module | Module | Identical |
| RoHS Status | RoHS Compliant | RoHS Compliant | Identical |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Product Status | Obsolete | Active | Substitute is Active |
Engineering Selection Recommendations
The Phoenix Contact 2900367 is the direct functional equivalent for the obsolete 2967484. Both components share identical electrical specifications, mechanical form factors, and regulatory compliance certifications. The 2900367 is classified as an active product with current manufacturing status, ensuring availability and supply chain continuity. Both parts maintain RoHS Compliance and MSL Level 1 ratings, confirming suitability for standard industrial control applications without additional environmental precautions.
Selection of the 2900367 as a replacement for the 2967484 requires no circuit redesign, PCB layout modification, or control logic adjustment. The transition from the PLC-OSP series (2967484) to the PLC-OPT series (2900367) maintains full functional compatibility while providing access to an actively manufactured component.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 2900367 directly replace the 2967484 in existing installations?
A: Yes. Both components are SPST-NO solid-state relay modules with identical electrical ratings (120VAC/DC input, 3-33V DC output, 3A load current), DIN rail mounting, and spring terminal connections. No circuit modifications are required.
Q: What is the primary reason for substitution?
A: The 2967484 is classified as obsolete. The 2900367 is an active product from Phoenix Contact that meets all electrical and mechanical specifications of the original part.
Q: Are there differences between the PLC-OSP and PLC-OPT series?
A: The provided specifications indicate both parts are SPST-NO modules with identical functional parameters. Series designation reflects internal Phoenix Contact product line organization but does not affect electrical or mechanical compatibility for this application.
Q: Do both parts meet the same regulatory requirements?
A: Yes. Both the 2967484 and 2900367 are RoHS Compliant with MSL Level 1 ratings, meeting standard industrial control environment requirements.
Q: What is the inventory status for the substitute part?
A: The Phoenix Contact 2900367 has 771 pieces in stock as new original inventory, providing immediate availability for replacement applications.
Q: Are the termination methods identical?
A: Yes. Both components use spring terminal connections, ensuring direct mechanical compatibility without adapter requirements or terminal reconfiguration.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts