Phoenix Contact 2962476 Interface Module Terminal Block - Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 2962476 is a 14-position interface module terminal block designed for screw connection to rectangular male connectors. This component belongs to the VARIOFACE COMPACT-LINE UM series and is classified as an active product with full RoHS compliance. The module accommodates wire gauges from 14-26 AWG and operates within a rated voltage range of 25VAC/50VDC with a current capacity of 1 A per contact. Finding equivalent or substitute parts may be necessary due to inventory constraints, application-specific dimensional requirements, or wire gauge compatibility needs in system integration scenarios.

Substiute Parts

2962476
Phoenix ContactIn Stock: 9132962476 Datasheet
2962476
Current Part
2315214
Phoenix ContactIn Stock: 8892315214 Datasheet
2315214
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 2962476
Manufacturer Phoenix Contact
Category Terminal Blocks
Series VARIOFACE COMPACT-LINE UM
Positions / Poles 14
Process Side Connection Terminal Blocks - Screw Connection
Control Side Connection Rectangular, Male
Wire Gauge 14-26 AWG
Voltage - Rated 25VAC, 50VDC
Current Rating (Per Contact) 1 A
Operating Temperature -20°C ~ 50°C
Length 2.323" (59.00mm)
Width 1.772" (45.00mm)
Product Status Active
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the Phoenix Contact 2962476 is determined by the following critical parameters:

Primary Compatibility Criteria:

  • Identical position count (14 poles)
  • Matching connection types (screw connection to rectangular male connector)
  • Compatible wire gauge range (overlap or equivalence within 12-26 AWG spectrum)
  • Voltage rating equal to or exceeding 25VAC/50VDC
  • Current rating of 1 A per contact minimum
  • Operating temperature range encompassing -20°C to 50°C
  • Control side cable retainer type (latches)

Identified Substitute: Phoenix Contact 2315214 meets the core functional requirements as a 14-position interface module terminal block with screw connection to rectangular male connectors. The primary distinction lies in wire gauge specification (12-24 AWG versus 14-26 AWG) and physical dimensions, which represent acceptable trade-offs in specific application contexts where the narrower wire gauge range is compatible with system requirements.

Parameter Comparison

Parameter 2962476 (Main Part) 2315214 (Substitute)
Manufacturer Phoenix Contact Phoenix Contact
Category Terminal Blocks Terminal Blocks
Positions / Poles 14 14
Process Side Connection Terminal Blocks - Screw Connection Terminal Blocks - Screw Connection
Control Side Connection Rectangular, Male Rectangular, Male
Control Side Cable Retainer Latches Latches
Wire Gauge 14-26 AWG 12-24 AWG
Voltage - Rated 25VAC, 50VDC 60V
Current Rating (Per Contact) 1 A 1 A
Operating Temperature -20°C ~ 50°C -20°C ~ 50°C
Length 2.323" (59.00mm) 1.567" (39.80mm)
Width 1.772" (45.00mm) 2.579" (65.50mm)
Product Status Active Active
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

Both the Phoenix Contact 2962476 and 2315214 maintain active product status with full regulatory compliance. The 2962476 carries RoHS certification, while the 2315214 meets the more stringent ROHS3 standard. Both components are classified as MSL 1 (Unlimited moisture sensitivity), indicating no special handling requirements during storage or assembly.

Selection between these parts should be based on:

  1. Wire Gauge Compatibility: The 2962476 accommodates 14-26 AWG wire, while the 2315214 supports 12-24 AWG. Applications using 25-26 AWG wire require the 2962476. Applications using 12-13 AWG wire require the 2315214. For wire gauges within the 14-24 AWG overlap range, either part is functionally equivalent.

  2. Voltage Rating: The 2315214 provides a higher voltage rating (60V) compared to the 2962476 (25VAC/50VDC). Applications requiring voltage ratings above 50VDC benefit from the 2315214.

  3. Physical Dimensions: The 2962476 measures 59.00mm × 45.00mm, while the 2315214 measures 39.80mm × 65.50mm. Enclosure space constraints or mounting geometry requirements may dictate part selection.

  4. Regulatory Compliance: Both parts satisfy RoHS requirements. The 2315214's ROHS3 compliance provides enhanced regulatory alignment for applications with stringent environmental standards.

Frequently Asked Questions (FAQ)

Q: Can the 2315214 substitute for the 2962476 in all applications?

A: Substitution is valid only when the application wire gauge falls within the 14-24 AWG overlap range, the voltage requirement does not exceed 60V, and the physical dimensions of the 2315214 (39.80mm × 65.50mm) are compatible with the enclosure or mounting configuration.

Q: What is the significance of the wire gauge difference between these parts?

A: Wire gauge determines the cross-sectional area of conductor that can be safely terminated. The 2962476 accepts larger conductors (up to 26 AWG equivalent) and smaller conductors (down to 14 AWG), while the 2315214 accepts a narrower range (12-24 AWG). Applications using 25-26 AWG wire cannot use the 2315214.

Q: Are there differences in electrical performance between these parts?

A: Both parts maintain identical current ratings (1 A per contact) and operating temperature ranges (-20°C to 50°C). The 2315214 provides higher voltage capability (60V versus 50VDC), which may be advantageous in high-voltage applications.

Q: How do the physical dimensions affect part selection?

A: The 2962476 is longer (59.00mm) but narrower (45.00mm), while the 2315214 is shorter (39.80mm) but wider (65.50mm). Enclosure space, panel layout, and mounting constraints determine which dimensional profile is acceptable for a given application.

Q: Do both parts require special handling during storage or assembly?

A: No. Both components are classified as MSL 1 (Unlimited), indicating they do not require moisture-controlled storage or special handling procedures during manufacturing or assembly processes.

Q: What is the difference between RoHS and ROHS3 compliance?

A: Both certifications restrict hazardous substances in electrical and electronic equipment. ROHS3 represents a more recent regulatory iteration with potentially enhanced restrictions. Both parts meet environmental compliance requirements; the 2315214 provides alignment with the latest regulatory standard.

Request Quote (Ships tomorrow)