Phoenix Contact 2910375 Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 2910375 is a Type 2 Transient Voltage Suppressor (TVS) device designed for surge protection in 277/480V electrical systems. This single-pole, DIN rail-mounted protective device is classified as circuit protection equipment and maintains active product status with full inventory availability. Substitute parts are identified to provide alternative sourcing options when the primary component is unavailable or when system design requires different electrical characteristics within compatible operating parameters.

Substiute Parts

2910375
Phoenix ContactIn Stock: 9312910375 Datasheet
2910375
Current Part
SPD2-300-4P0-R
Littelfuse Inc.In Stock: 1075SPD2-300-4P0-R Datasheet
SPD2-300-4P0-R
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 2910375
Manufacturer Phoenix Contact
Category Transient Voltage Suppressors (TVS)
Series VAL-US
Type Type 2
Number of Poles 1
Voltage - Continuous Operating (Max) (MCOV) 385VAC
Current - Discharge (Nom) (8/20µS) 40 kA
Current - Discharge (Max) (8/20µS) 40 kA
Current - Short Circuit Rating (SCRR) 25 kA
Voltage - Protection Rating (VPR) 2.5 kV
Voltage - Protection Level (VP) (2416) 4 kV
Operating Temperature -40°C ~ 80°C
Mounting Type DIN Rail
Approval Agency cUL, UL
RoHS Status ROHS3 Compliant
Product Status Active

Substitute Part Grouping Explanation

Substitution eligibility for the Phoenix Contact 2910375 is determined by the following critical parameters:

Primary Substitution Criteria:

  • Category: Transient Voltage Suppressors (TVS) / Circuit Protection
  • Mounting Type: DIN Rail
  • Operating Temperature Range: -40°C ~ 80°C minimum
  • RoHS Compliance: ROHS3 Compliant
  • Regulatory Approvals: UL certification required

Electrical Compatibility Considerations:

  • Voltage - Continuous Operating (Max) (MCOV): Must support minimum 385VAC
  • Current - Discharge (Max) (8/20µS): Must support minimum 40 kA
  • Voltage - Protection Level (VP) (2416): Must support minimum 4 kV

The substitute part SPD2-300-4P0-R is identified based on shared category classification, DIN rail mounting, compatible operating temperature range, ROHS3 compliance, and UL certification. However, electrical parameter differences exist and must be evaluated against specific application requirements.

Parameter Comparison

Parameter Phoenix Contact 2910375 Littelfuse SPD2-300-4P0-R
Manufacturer Phoenix Contact Littelfuse Inc.
Category Transient Voltage Suppressors (TVS) Transient Voltage Suppressors (TVS)
Type Type 2 Type 1, Type 2
Voltage - Continuous Operating (Max) (MCOV) 385VAC 300VAC
Current - Discharge (Nom) (8/20µS) 40 kA 20 kA
Current - Discharge (Max) (8/20µS) 40 kA 50 kA
Current - Short Circuit Rating 25 kA (SCRR) 150 kA (SCCR)
Voltage - Protection Rating (VPR) 2.5 kV 900 V
Voltage - Protection Level (VP) (2416) 4 kV 1.5 kV
Operating Temperature -40°C ~ 80°C -40°C ~ 80°C
Mounting Type DIN Rail DIN Rail
Approval Agency cUL, UL CE, cURus, UL, VDE
RoHS Status ROHS3 Compliant ROHS3 Compliant
Product Status Active Active

Engineering Selection Recommendations

Both the Phoenix Contact 2910375 and Littelfuse SPD2-300-4P0-R maintain active product status and ROHS3 compliance. Both devices are UL-certified and support the required -40°C to 80°C operating temperature range with DIN rail mounting.

The Phoenix Contact 2910375 is specified for 277/480V systems with higher continuous operating voltage (385VAC MCOV) and higher protection voltage ratings (2.5 kV VPR, 4 kV VP). The Littelfuse SPD2-300-4P0-R operates at 300VAC MCOV with lower protection voltage ratings (900 V VPR, 1.5 kV VP) but provides higher short-circuit current rating (150 kA SCCR) and includes thermally protected and remote signaling contact features.

Selection between these devices depends on system voltage requirements and surge protection specifications. The Phoenix Contact device is appropriate for higher-voltage applications, while the Littelfuse device is suitable for lower-voltage systems requiring enhanced short-circuit protection and signaling capabilities.

Frequently Asked Questions (FAQ)

Q: Can the Littelfuse SPD2-300-4P0-R directly replace the Phoenix Contact 2910375?

A: Direct replacement is not recommended. The Littelfuse device operates at 300VAC MCOV compared to the Phoenix Contact's 385VAC MCOV. The protection voltage ratings differ significantly (1.5 kV VP versus 4 kV VP). Application voltage requirements must be evaluated before substitution.

Q: What are the key electrical differences between these devices?

A: The Phoenix Contact 2910375 provides higher continuous operating voltage (385VAC) and higher protection voltage levels (2.5 kV VPR, 4 kV VP). The Littelfuse SPD2-300-4P0-R operates at lower voltage (300VAC MCOV) but offers higher short-circuit current rating (150 kA SCCR versus 25 kA SCRR) and includes thermally protected and remote signaling contact features.

Q: Are both devices DIN rail mountable?

A: Yes, both devices are DIN rail-mounted and support the same operating temperature range (-40°C to 80°C).

Q: What certifications do these devices hold?

A: The Phoenix Contact 2910375 holds cUL and UL certifications. The Littelfuse SPD2-300-4P0-R holds CE, cURus, UL, and VDE certifications. Both are ROHS3 compliant.

Q: What is the difference between Type 1 and Type 2 protection?

A: The Phoenix Contact 2910375 is Type 2 protection. The Littelfuse SPD2-300-4P0-R provides both Type 1 and Type 2 protection. Type classification relates to surge protection coordination within electrical distribution systems.

Q: How do the discharge current ratings compare?

A: The Phoenix Contact 2910375 has nominal and maximum discharge current of 40 kA (8/20µS). The Littelfuse SPD2-300-4P0-R has nominal discharge current of 20 kA and maximum discharge current of 50 kA (8/20µS).