Request Quote
(Ships tomorrow)
Phoenix Contact 2903284 General Purpose Relay - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 2903284 is a general purpose relay featuring a 3PST-NO (3 Form A) contact configuration with a 24VDC coil, rated for 10A switching capacity. This DIN rail-mounted relay is designed for industrial control applications requiring reliable switching of AC and DC loads. The part is currently obsolete, making identification of suitable substitute components essential for system maintenance and new designs requiring equivalent functionality.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Phoenix Contact |
| Series | RIF |
| Coil Voltage | 24VDC |
| Contact Form | 3PST-NO (3 Form A) |
| Contact Rating | 10 A |
| Switching Voltage | 440VAC, 250VDC - Max |
| Mounting Type | DIN Rail |
| Coil Current | 70 mA |
| Operating Temperature Range | -40°C ~ 60°C |
| Contact Material | Silver Nickel (AgNi) |
| Termination Style | Screw Terminal |
Substitute Part Grouping Explanation
Substitution of the Phoenix Contact 2903284 is determined by the following critical parameters:
- Coil Voltage: Must be 24VDC to maintain compatibility with existing control circuits
- Mounting Type: DIN rail mounting is required for panel integration
- Contact Rating: 10A minimum capacity for load switching
- Switching Voltage: 440VAC/250VDC maximum rating ensures safe operation across AC and DC applications
- Termination Style: Screw terminal connection for reliable wiring integration
- Series Compatibility: Phoenix Contact RIF series maintains mechanical and electrical consistency
The Phoenix Contact 2903288 qualifies as a substitute based on matching these core parameters, with the distinction that it provides 3PDT (3 Form C) contact configuration instead of 3PST-NO (3 Form A).
Parameter Comparison
| Parameter | 2903284 (Main Part) | 2903288 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Series | RIF | RIF |
| Coil Voltage | 24VDC | 24VDC |
| Contact Form | 3PST-NO (3 Form A) | 3PDT (3 Form C) |
| Contact Rating (Current) | 10 A | 10 A |
| Switching Voltage | 440VAC, 250VDC - Max | 440VAC, 250VDC - Max |
| Mounting Type | DIN Rail | DIN Rail |
| Coil Current | 70 mA | 56 mA |
| Operate Time | 20 ms | 20 ms |
| Release Time | 20 ms | 20 ms |
| Operating Temperature | -40°C ~ 60°C | -40°C ~ 60°C |
| Contact Material | Silver Nickel (AgNi) | Silver Nickel (AgNi) |
| Termination Style | Screw Terminal | Screw Terminal |
| Coil Resistance | 343 Ohms | 429 Ohms |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
The Phoenix Contact 2903288 is available as an active product with current manufacturing support, whereas the 2903284 is obsolete. Both relays maintain identical coil voltage, contact rating, switching voltage, and operating temperature specifications. The 2903288 provides enhanced compliance status with ROHS3 certification and REACH compliance documentation.
The primary functional difference is the contact configuration: the 2903284 provides 3PST-NO (3 Form A) contacts, while the 2903288 provides 3PDT (3 Form C) contacts. This distinction affects circuit design requirements. The 2903288 also demonstrates lower coil current consumption (56 mA versus 70 mA), reducing control circuit power demands.
Selection of the 2903288 as a substitute is appropriate when the application can accommodate the 3PDT contact configuration. If the circuit design specifically requires 3PST-NO functionality, alternative substitutes within the Phoenix Contact RIF series should be evaluated.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 2903288 directly replace the 2903284 in existing installations?
A: Direct replacement is possible if the circuit design accommodates 3PDT (3 Form C) contact functionality. The 2903288 provides additional switching capability compared to the 3PST-NO configuration of the 2903284. Verify that the application does not require the specific 3PST-NO contact form before substitution.
Q: What is the difference between 3PST-NO and 3PDT contact configurations?
A: 3PST-NO (3 Form A) provides three independent normally-open contacts, each capable of closing a circuit. 3PDT (3 Form C) provides three changeover contacts, each with both normally-open and normally-closed positions. The 3PDT configuration offers greater switching flexibility for complex control logic.
Q: Are the coil voltage and current specifications compatible between these relays?
A: Both relays operate on 24VDC coil voltage. The 2903288 requires 56 mA coil current compared to 70 mA for the 2903284. This lower current requirement in the substitute part reduces control circuit power consumption and may improve compatibility with lower-capacity control power supplies.
Q: What compliance certifications apply to the substitute part?
A: The Phoenix Contact 2903288 is ROHS3 compliant and REACH affected. The original 2903284 is RoHS compliant. Both parts carry EAR99 ECCN classification and HTSUS code 8536.41.0050.
Q: Are packaging differences significant for system integration?
A: The 2903284 is packaged with socket inclusion, while the 2903288 is supplied in bulk packaging. Both utilize screw terminal termination and DIN rail mounting, ensuring mechanical compatibility in panel installations.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts