Phoenix Contact 2902969 SSR Relay SPST-NO Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 2902969 is a solid-state relay (SSR) with SPST-NO (1 Form A) configuration, designed for low-current DC switching applications. This component operates with a 5VDC input signal and supports load voltages from 4V to 30V at 50mA maximum current. The part is classified as obsolete, making identification of suitable substitute components essential for ongoing system maintenance and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Phoenix Contact |
| Part Number | 2902969 |
| Circuit Configuration | SPST-NO (1 Form A) |
| Output Type | DC |
| Input Voltage | 5VDC |
| Load Voltage Range | 4V ~ 30V |
| Load Current | 50mA |
| Mounting Type | DIN Rail |
| Termination Style | Spring Terminal |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 2902969 is determined by the following critical parameters:
- Circuit configuration must remain SPST-NO (1 Form A)
- Input voltage must be 5VDC
- Output type must be DC
- Load current rating must support minimum 50mA
- Mounting type must be DIN Rail compatible
- Termination style must be Spring Terminal
The Phoenix Contact 2902973 qualifies as a substitute based on these criteria. The primary difference is the load voltage range specification: the 2902973 operates within 14V to 30V, which represents a narrower operating window compared to the original 4V to 30V range. This substitution is valid for applications where the load voltage remains within the 14V to 30V band.
Parameter Comparison
| Parameter | 2902969 (Original) | 2902973 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Series | PLC | PLC-OPT |
| Circuit Configuration | SPST-NO (1 Form A) | SPST-NO (1 Form A) |
| Output Type | DC | DC |
| Input Voltage | 5VDC | 5VDC |
| Load Voltage Range | 4V ~ 30V | 14V ~ 30V |
| Load Current | 50mA | 50mA |
| Mounting Type | DIN Rail | DIN Rail |
| Termination Style | Spring Terminal | Spring Terminal |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The Phoenix Contact 2902973 is the qualified substitute for the obsolete 2902969 model. Both components share identical electrical specifications for input voltage, output type, circuit configuration, and load current capacity. The 2902973 offers the advantage of active product status, ensuring continued availability and support.
The 2902973 carries ROHS3 compliance and REACH affected status, representing current regulatory alignment. The narrower load voltage range (14V ~ 30V versus 4V ~ 30V) must be evaluated against specific application requirements. If the system operates exclusively within the 14V to 30V window, the 2902973 provides a direct functional replacement. Applications requiring operation below 14V load voltage cannot use the 2902973 as a substitute.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 2902973 replace the 2902969 in all applications?
A: The 2902973 is functionally equivalent for applications where load voltage remains between 14V and 30V. If your system requires operation at load voltages below 14V, the 2902973 is not suitable. Verify your load voltage specifications before substitution.
Q: What is the primary difference between these two SSR relays?
A: The load voltage operating range differs. The 2902969 supports 4V to 30V, while the 2902973 supports 14V to 30V. All other electrical and mechanical parameters are identical.
Q: Why is the 2902969 listed as obsolete?
A: The 2902969 has been discontinued by Phoenix Contact. The 2902973 represents the current active product line replacement within the PLC-OPT series.
Q: Are there any compliance differences between these parts?
A: The 2902973 carries ROHS3 compliance and REACH affected status, reflecting current regulatory requirements. The 2902969 is RoHS Compliant. Both maintain MSL rating 1 (Unlimited).
Q: Do both relays use the same mounting and termination methods?
A: Yes. Both components mount on DIN Rail and use Spring Terminal termination, ensuring mechanical compatibility in existing installations.
Q: What load current capacity do these relays support?
A: Both the 2902969 and 2902973 are rated for 50mA maximum load current at their respective voltage ranges.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts