Phoenix Contact 2714019 Terminal Block Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 2714019 is a CLIPLINE PIK series terminal block connector designed for feed-through applications with 5 positions across 3 levels, supporting wire gauges from 12-28 AWG. This component is classified as obsolete, necessitating identification of active equivalent parts to maintain system functionality and ensure continued availability for new designs and replacements.

Substiute Parts

2714019
Phoenix ContactIn Stock: 11172714019 Datasheet
2714019
Current Part
3076030
Phoenix ContactIn Stock: 7893076030 Datasheet
3076030
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 2714019
Manufacturer Phoenix Contact
Category Terminal Blocks
Series CLIPLINE PIK
Product Status Obsolete
Type Feed Through (2), Isolated
Number of Positions 5
Number of Levels 3 (1 Grounded)
Termination Style Screw
Wire Gauge - AWG 12-28 AWG
Wire Gauge - mm² 0.2-4 mm²
Current - IEC 32 A
Current - UL 20 A
Voltage - UL 300 V
Color Gray
Material - Insulation Polyamide (PA), Nylon
Material Flammability Rating UL94 V-2
RoHS Status RoHS Compliant
MSL 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the obsolete Phoenix Contact 2714019 is based on the following critical parameters that must remain consistent:

  • Connector Type: Feed Through (2), Isolated configuration
  • Position Count: 5 positions maintained across 3 levels with 1 grounded
  • Termination Method: Screw termination
  • Wire Gauge Compatibility: Minimum support for 12-26 AWG range (subset of original 12-28 AWG)
  • Current Rating: UL rating of 20 A minimum
  • Voltage Rating: UL 300 V
  • Insulation Material: Polyamide (PA), Nylon
  • Color: Gray

The Phoenix Contact 3076030 from the CLIPLINE UT series qualifies as a substitute based on these parameters. While the wire gauge range is narrower (12-26 AWG versus 12-28 AWG) and the IEC current rating is reduced (24 A versus 32 A), the UL ratings and core electrical specifications remain compatible for standard applications.

Parameter Comparison

Parameter 2714019 (Main Part) 3076030 (Substitute) Compatibility Notes
Manufacturer Phoenix Contact Phoenix Contact Same manufacturer
Category Terminal Blocks Terminal Blocks Same category
Type Feed Through (2), Isolated Feed Through (2), Isolated Identical configuration
Number of Positions 5 5 Identical
Number of Levels 3 (1 Grounded) 3 (1 Grounded) Identical
Termination Style Screw Screw Identical
Wire Gauge - AWG 12-28 AWG 12-26 AWG Substitute range is subset; 28 AWG not supported
Wire Gauge - mm² 0.2-4 mm² 0.2-4 mm² Identical
Current - IEC 32 A 24 A Substitute rated lower; verify application requirements
Current - UL 20 A 20 A Identical
Voltage - UL 300 V 300 V Identical
Color Gray Gray Identical
Material - Insulation Polyamide (PA), Nylon Polyamide (PA), Nylon Identical
Material Flammability Rating UL94 V-2 UL94 V-0 Substitute has superior flammability rating
RoHS Status RoHS Compliant ROHS3 Compliant Substitute meets current RoHS3 standard
Product Status Obsolete Active Substitute is actively manufactured

Engineering Selection Recommendations

The Phoenix Contact 3076030 is the qualified substitute for the obsolete 2714019 based on the following engineering criteria:

Compliance and Availability: The 3076030 is an active product with current manufacturing status, ensuring long-term availability and supply chain continuity. It meets ROHS3 compliance, representing the current regulatory standard, and achieves a superior UL94 V-0 flammability rating compared to the V-2 rating of the original part.

Electrical Compatibility: Both parts maintain identical UL voltage (300 V) and UL current (20 A) ratings, ensuring compatibility in applications designed to these specifications. The IEC current rating difference (24 A versus 32 A) must be evaluated against specific application requirements.

Physical and Functional Compatibility: The substitute maintains identical position count (5), level configuration (3 levels with 1 grounded), termination method (screw), insulation material (Polyamide/Nylon), and color (gray). Terminal width differs (5.2 mm versus 6.2 mm), which may affect mechanical fit in existing assemblies.

Wire Gauge Consideration: The substitute supports 12-26 AWG, which excludes 28 AWG from the original specification. Applications utilizing 28 AWG conductors require alternative solutions or design modification.

Frequently Asked Questions (FAQ)

Q: Can the 3076030 directly replace the 2714019 in existing assemblies?

A: Physical compatibility depends on terminal width tolerance. The 3076030 has a 5.2 mm terminal width versus 6.2 mm for the 2714019. Mechanical fit in existing mounting structures must be verified before implementation.

Q: What is the impact of the narrower wire gauge range in the substitute?

A: The 3076030 supports 12-26 AWG, excluding 28 AWG from the original 12-28 AWG range. If 28 AWG conductors are used in the application, the substitute is not compatible. Applications using 12-26 AWG are fully supported.

Q: Are the electrical ratings equivalent for my application?

A: UL ratings are identical (20 A, 300 V). The IEC current rating differs (24 A versus 32 A). Applications designed to UL specifications are compatible. Applications requiring IEC 32 A rating must evaluate whether the 24 A rating of the substitute meets operational requirements.

Q: What compliance advantages does the 3076030 offer?

A: The substitute meets ROHS3 compliance (current standard) and achieves UL94 V-0 flammability rating, superior to the V-2 rating of the original part. These represent current regulatory and safety standards.

Q: Is the substitute available in the same packaging as the original?

A: The 3076030 is supplied in bulk packaging, whereas the original 2714019 packaging specification was not provided. Packaging requirements for production or inventory management should be confirmed with the supplier.

Q: What is the terminal width difference and does it matter?

A: The 3076030 has a 5.2 mm terminal width compared to 6.2 mm for the 2714019. This 1 mm difference may affect mechanical fit in existing PCB layouts or mounting structures. Physical verification is required before design implementation.