Honeywell 26PCDFG5G39 Pressure Sensor Equivalent & Substitute Parts

Part Overview

The Honeywell 26PCDFG5G39 is an active, board-mount pressure sensor designed for compound pressure measurement applications. This ±30PSI (±206.84kPa) sensor features a Wheatstone Bridge output with 0 mV ~ 100 mV signal range and operates across -40°C to 85°C. The component utilizes a barbed male port (0.14" tube) for pneumatic connection and through-hole PC pin termination for circuit board integration. Identifying equivalent substitute parts ensures design flexibility, supply chain continuity, and component availability across manufacturing cycles.

Substiute Parts

26PCDFG5G39
Honeywell Sensing and Productivity SolutionsIn Stock: 103326PCDFG5G39 Datasheet
26PCDFG5G39
Current Part
26PCDFG2G
Honeywell Sensing and Productivity SolutionsIn Stock: 1029826PCDFG2G Datasheet
26PCDFG2G
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 26PCDFG5G39
Manufacturer Honeywell Sensing and Productivity Solutions
Series 26PC
Pressure Type Compound
Operating Pressure ±30PSI (±206.84kPa)
Maximum Pressure ±60PSI (±413.69kPa)
Output Type Wheatstone Bridge
Output Range 0 mV ~ 100 mV (10V)
Accuracy ±0.2%
Supply Voltage 2.5V ~ 16V
Port Size Male - 0.14" (3.56mm) Tube
Port Style Barbed
Features Temperature Compensated
Operating Temperature -40°C ~ 85°C
Mounting Type Through Hole
Package / Case 4-SIP Module
Termination Style PC Pin
Product Status Active
RoHS Status RoHS Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the 26PCDFG5G39 are determined by strict equivalence across all critical electrical and mechanical parameters. The substitution logic is based on the following key parameters:

Pressure Specifications: Operating pressure range (±30PSI / ±206.84kPa) and maximum pressure rating (±60PSI / ±413.69kPa) must be identical.

Output Characteristics: Output type (Wheatstone Bridge), output range (0 mV ~ 100 mV at 10V), and accuracy (±0.2%) must match exactly.

Electrical Requirements: Supply voltage range (2.5V ~ 16V) must be identical to ensure circuit compatibility.

Mechanical Interface: Port size (Male - 0.14" / 3.56mm tube), port style (Barbed), and termination style (PC Pin) must be identical for physical and electrical connection compatibility.

Package and Mounting: Package type (4-SIP Module), mounting type (Through Hole), and temperature compensation feature must be identical.

Compliance and Status: Product status (Active), RoHS compliance, and MSL rating must match.

The 26PCDFG2G meets all these criteria and is classified as a parametric equivalent.

Parameter Comparison

Parameter 26PCDFG5G39 (Main Part) 26PCDFG2G (Substitute) Match Status
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Identical
Series 26PC 26PC Identical
Pressure Type Compound Compound Identical
Operating Pressure ±30PSI (±206.84kPa) ±30PSI (±206.84kPa) Identical
Maximum Pressure ±60PSI (±413.69kPa) ±60PSI (±413.69kPa) Identical
Output Type Wheatstone Bridge Wheatstone Bridge Identical
Output Range 0 mV ~ 100 mV (10V) 0 mV ~ 100 mV (10V) Identical
Accuracy ±0.2% ±0.2% Identical
Supply Voltage 2.5V ~ 16V 2.5V ~ 16V Identical
Port Size Male - 0.14" (3.56mm) Tube Male - 0.14" (3.56mm) Tube Identical
Port Style Barbed Barbed Identical
Features Temperature Compensated Temperature Compensated Identical
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C Identical
Mounting Type Through Hole Through Hole Identical
Package / Case 4-SIP Module 4-SIP Module Identical
Termination Style PC Pin PC Pin Identical
Product Status Active Active Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
MSL Rating 1 (Unlimited) 1 (Unlimited) Identical

Engineering Selection Recommendations

The 26PCDFG2G is a direct parametric equivalent to the 26PCDFG5G39. Both components are manufactured by Honeywell Sensing and Productivity Solutions, carry Active product status, and maintain identical electrical, mechanical, and environmental specifications. Both parts are RoHS Compliant with MSL Rating 1 (Unlimited), ensuring compliance with industry standards and manufacturing requirements.

Selection between these parts should be based on inventory availability and supply chain considerations. The 26PCDFG2G currently maintains higher inventory levels (10,200 pcs) compared to the 26PCDFG5G39 (934 pcs), which may influence procurement decisions for high-volume applications or extended lead-time mitigation.

Frequently Asked Questions (FAQ)

Q: Can the 26PCDFG2G be used as a direct replacement for the 26PCDFG5G39?

A: Yes. The 26PCDFG2G is a parametric equivalent with identical electrical specifications, mechanical interface, package type, and operating characteristics. No circuit modifications or mechanical redesign is required.

Q: Are the pressure ratings identical between these parts?

A: Yes. Both parts operate at ±30PSI (±206.84kPa) with a maximum pressure rating of ±60PSI (±413.69kPa). Pressure type (Compound), output type (Wheatstone Bridge), and accuracy (±0.2%) are identical.

Q: Do both parts have the same physical connector and mounting requirements?

A: Yes. Both parts feature a barbed male port (0.14" / 3.56mm tube), PC pin through-hole termination, and 4-SIP module packaging. No mechanical adaptation is necessary for board-level integration.

Q: Are there any compliance or certification differences?

A: No. Both parts are RoHS Compliant with MSL Rating 1 (Unlimited). Regulatory and environmental compliance status is identical.

Q: What is the supply voltage compatibility?

A: Both parts operate with identical supply voltage range: 2.5V ~ 16V. Circuit power supply specifications do not require modification when substituting between these parts.

Q: Are the temperature operating ranges the same?

A: Yes. Both parts operate across -40°C to 85°C with temperature compensation features. Thermal performance and environmental operating limits are identical.

Q: What is the output signal format for both parts?

A: Both parts provide Wheatstone Bridge output with 0 mV ~ 100 mV signal range at 10V excitation. Signal conditioning and measurement interface requirements are identical.

Request Quote (Ships tomorrow)