Request Quote
(Ships tomorrow)
E-T-A 2-5200-5A Circuit Breaker Thermal 5A Equivalent & Substitute Parts
Part Overview
The E-T-A 2-5200-5A is a single-pole thermal circuit breaker rated for 5A at 250V AC and 50V DC with push-to-reset actuation and panel mount configuration. This component is classified as Active product status and carries multiple international approvals including CSA C22.2 No 235, IEC 60934, and UL1077 certifications. Substitute parts are identified based on matching electrical ratings, mechanical mounting characteristics, and regulatory compliance to ensure direct functional equivalence in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2-5200-5A |
| Manufacturer | E-T-A |
| Series | 2-5200 |
| Breaker Type | Thermal |
| Current Rating | 5A |
| Voltage Rating - AC | 250V |
| Voltage Rating - DC | 50V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Active |
| Approval Agencies | CSA C22.2 No 235, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the 2-5200-5A are qualified based on the following electrical and mechanical parameters:
- Current Rating: 5A (exact match required)
- Voltage Rating - AC: 250V (exact match required)
- Voltage Rating - DC: 50V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Push to Reset (exact match required)
- Number of Poles: 1 (exact match required)
- Approval Agencies: CSA C22.2 No 235, IEC 60934, UL1077 (all certifications required)
All identified substitute parts meet these criteria and are manufactured by E-T-A with Active product status.
Parameter Comparison
| Parameter | 2-5200-5A | 1140-G151-P7M1-5A | 1410-G110-L2F1-S01-5A | 1410-G111-L2F1-S01-5A |
|---|---|---|---|---|
| Manufacturer | E-T-A | E-T-A | E-T-A | E-T-A |
| Series | 2-5200 | 1140 | 1410-G1 | 1410-G1 |
| Breaker Type | Thermal | Thermal | Thermal | Thermal |
| Current Rating (Amps) | 5A | 5A | 5A | 5A |
| Voltage Rating - AC | 250V | 250V | 250V | 250V |
| Voltage Rating - DC | 50V | 50V | 50V | 50V |
| Mounting Type | Panel Mount | Panel Mount | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 | 1 | 1 |
| Product Status | Active | Active | Active | Active |
| Approval Agencies | CSA C22.2 No 235, IEC 60934, UL1077 | CSA C22.2 No 235, IEC 60934, UL1077 | CSA C22.2 No 235, IEC 60934, UL1077 | CSA C22.2 No 235, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | RoHS Compliant | RoHS Compliant |
Engineering Selection Recommendations
All three substitute parts (1140-G151-P7M1-5A, 1410-G110-L2F1-S01-5A, and 1410-G111-L2F1-S01-5A) are direct functional equivalents to the 2-5200-5A. Selection among these alternatives is based on availability and inventory status:
- 1140-G151-P7M1-5A: 2100 pcs in stock
- 1410-G110-L2F1-S01-5A: 929 pcs in stock
- 1410-G111-L2F1-S01-5A: 1168 pcs in stock
All parts carry identical electrical ratings, mechanical specifications, and regulatory certifications (CSA C22.2 No 235, IEC 60934, UL1077). RoHS compliance is maintained across all options. Component selection should prioritize availability requirements and supply chain considerations.
Frequently Asked Questions (FAQ)
Q: Can 1140-G151-P7M1-5A be used as a direct replacement for 2-5200-5A?
A: Yes. Both parts are single-pole thermal circuit breakers with identical current ratings (5A), voltage ratings (250V AC / 50V DC), push-to-reset actuation, panel mount configuration, and regulatory approvals. Electrical and mechanical compatibility is confirmed.
Q: Are there differences in RoHS compliance between the main part and substitutes?
A: The main part 2-5200-5A is ROHS3 Compliant. Substitute parts 1410-G110-L2F1-S01-5A and 1410-G111-L2F1-S01-5A are listed as RoHS Compliant. Both designations indicate compliance with RoHS directives; the specific version designation reflects manufacturing documentation standards.
Q: What certifications must be maintained when selecting a substitute?
A: All substitute parts must carry the same regulatory approvals as the original: CSA C22.2 No 235, IEC 60934, and UL1077. All identified substitutes meet this requirement.
Q: Do all substitute parts have identical packaging?
A: Yes. All parts are supplied in Bulk packaging configuration.
Q: Can I use 1410-G110-L2F1-S01-5A and 1410-G111-L2F1-S01-5A interchangeably?
A: Yes. Both parts share identical electrical ratings, mechanical specifications, mounting type, actuator type, and regulatory certifications. They are functionally equivalent and interchangeable in circuit protection applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts