Equivalent & Substitute Parts Reference for E-T-A 2-5200-2A Circuit Breaker

Part Overview

Manufacturer part number 2-5200-2A from E-T-A is a thermal circuit breaker rated for 2A, with voltage ratings of 250 V AC and 50 V DC, utilizing a push-to-reset actuator and designed for panel mounting with 1 pole. The component is obsolete, making the identification of parametric equivalent substitute parts necessary to ensure availability in applications requiring identical electrical, mechanical, and compliance characteristics.

Substiute Parts

2-5200-2A
E-T-AIn Stock: 10132-5200-2A Datasheet
2-5200-2A
Current Part
1140-G151-P7M1-2A
E-T-AIn Stock: 7761140-G151-P7M1-2A Datasheet
1140-G151-P7M1-2A
Parametric Equivalent
1410-G110-L2F1-S01-2A
1410-G110-L2F1-S01-2A
Parametric Equivalent
1410-G110-P2F1-S01-2A
1410-G110-P2F1-S01-2A
Parametric Equivalent
1410-G111-L2F1-S01-2A
1410-G111-L2F1-S01-2A
Parametric Equivalent
1410-G111-P2F1-S01-2A
1410-G111-P2F1-S01-2A
Parametric Equivalent
1410-G114-P3F1-S01-2A
1410-G114-P3F1-S01-2A
Parametric Equivalent

Key Parameters

Manufacturer Part Number Series Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Mounting Type Number of Poles Illumination Approval Agency RoHS Status Inventory Product Status
2-5200-2A 2-5200 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 ROHS3 Compliant 964 Obsolete

Substitute Part Grouping Explanation

Substitute components are identified strictly by parametric equivalence in the following key parameters: breaker type (thermal), current rating (2A), voltage ratings (250 V AC, 50 V DC), actuator type (push to reset), mounting type (panel mount), number of poles (1), illumination (none), approval agency certifications, and environmental compliance status. Only models matching these criteria are included as valid substitutes.

Parameter Comparison

Manufacturer Part Number Series Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Mounting Type Number of Poles Illumination Approval Agency RoHS Status Inventory Product Status
2-5200-2A 2-5200 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 ROHS3 Compliant 964 Obsolete
1140-G151-P7M1-2A 1140 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 ROHS3 Compliant 727 Active
1410-G110-L2F1-S01-2A 1410-G1 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 RoHS Compliant 806 Active
1410-G110-P2F1-S01-2A 1410-G1 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 RoHS Compliant 869 Active
1410-G111-L2F1-S01-2A 1410-G1 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 RoHS Compliant 1144 Active
1410-G111-P2F1-S01-2A 1410-G1 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 RoHS Compliant 653 Active
1410-G114-P3F1-S01-2A 1410-G1 Thermal 2A 250 V 50 V Push to Reset Panel Mount 1 None CSA C22.2 No 235, IEC 60934, UL1077 RoHS Compliant 897 Active

Engineering Selection Recommendations

Selection of a substitute for E-T-A 2-5200-2A should be based on matching product status (active vs. obsolete), confirmed RoHS and REACH compliance, and certifications from approval agencies CSA C22.2 No 235, IEC 60934, and UL1077. Substitute models listed above are all RoHS and REACH compliant, maintain identical electrical and mechanical ratings, and adhere to the same agency standards.

Frequently Asked Questions (FAQ)

Q1: What are the mandatory criteria for selecting a substitute for 2-5200-2A?
A1: Substitutes must match in breaker type (thermal), current rating (2A), voltage ratings (250 V AC, 50 V DC), actuator type (push to reset), mounting type (panel mount), number of poles (1), illumination (none), approval agency compliance, and environmental compliance status.

Q2: Can substitute parts have different approval agency certifications?
A2: Only parts with the same approval agency certifications—CSA C22.2 No 235, IEC 60934, UL1077—are considered valid substitutes.

Q3: Are all listed substitutes RoHS compliant?
A3: All substitutes provided indicate RoHS compliance according to input parameters.

Q4: Does panel mounting type affect substitution compatibility?
A4: Yes. All substitutes must have panel mount compatibility to ensure direct replacement without mechanical modification.

Q5: What role does the actuator type play in substitution?
A5: Push-to-reset actuator type must be matched for functional and user interaction equivalence.

Q6: Is inventory availability considered in this equivalence guide?
A6: Inventory quantities are listed as provided, but equivalence is determined solely by parametric data—not by stock availability.

Request Quote (Ships tomorrow)