Request Quote
(Ships tomorrow)
Weidmüller MCB 489 2P 60A ACDC Circuit Breaker (2479010000)
Part Overview
The Weidmüller MCB 489 2P D 60A ACDC is a thermal magnetic circuit breaker designed for DIN rail mounting. This device provides overcurrent protection in AC and DC applications with a 60A current rating, 240V AC / 125V DC voltage capability, and lever-operated actuation. The part is currently active in production with full inventory availability (874 pcs in stock). Alternative models may be required due to application-specific requirements, regional availability, or design revisions within the same product series.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2479010000 |
| Manufacturer | Weidmüller |
| Series | MCB 489 |
| Breaker Type | Thermal Magnetic |
| Current Rating | 60A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 125V |
| Number of Poles | 2 |
| Mounting Type | DIN Rail |
| Actuator Type | Lever |
| Product Status | Active |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
The Weidmüller MCB 489 series permits substitution based on the following electrical and mechanical parameters:
Substitution Criteria (All Must Match):
- Breaker Type: Thermal Magnetic
- Current Rating: 60A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 125V
- Number of Poles: 2
- Mounting Type: DIN Rail
- Actuator Type: Lever
- Series: MCB 489
Allowed Variation:
- Characteristic curve designation (D-curve vs. C-curve) may differ based on application requirements, as both variants maintain identical electrical ratings and mechanical compatibility within the MCB 489 series.
The substitute part 2478270000 meets all core electrical and mechanical parameters while utilizing a C-curve characteristic instead of the D-curve of the main part.
Parameter Comparison
| Parameter | 2479010000 (Main Part) | 2478270000 (Substitute) |
|---|---|---|
| Manufacturer | Weidmüller | Weidmüller |
| Series | MCB 489 | MCB 489 |
| Breaker Type | Thermal Magnetic | Thermal Magnetic |
| Current Rating | 60A | 60A |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 125V | 125V |
| Number of Poles | 2 | 2 |
| Mounting Type | DIN Rail | DIN Rail |
| Actuator Type | Lever | Lever |
| Characteristic Curve | D-Curve | C-Curve |
| Product Status | Active | Active |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| Approval Agencies | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
Engineering Selection Recommendations
Both the main part (2479010000) and substitute part (2478270000) are active production components with identical regulatory compliance and certification status. Selection between these MCB 489 variants should be based on the required characteristic curve for the specific application:
- D-Curve (2479010000): Suitable for applications with moderate inrush currents and general-purpose circuit protection.
- C-Curve (2478270000): Suitable for applications with higher inrush currents or where delayed trip response is required.
Both parts maintain full compatibility with DIN rail mounting systems and are RoHS compliant with MSL 1 (unlimited moisture sensitivity level).
Frequently Asked Questions (FAQ)
Q: Can I substitute 2478270000 for 2479010000 in my application?
A: Substitution is permissible only if your application requirements support a C-curve characteristic instead of a D-curve. Both parts share identical electrical ratings (60A, 240V AC / 125V DC), mechanical mounting (DIN rail, 2-pole, lever actuation), and regulatory certifications. Verify that the characteristic curve change does not affect inrush current handling or trip response requirements for your circuit.
Q: What is the difference between D-curve and C-curve designations?
A: The characteristic curve determines the trip threshold and response time to overcurrent conditions. D-curve breakers trip at higher multiples of rated current with longer delay times, while C-curve breakers trip at lower multiples with shorter delay times. Selection depends on the specific load characteristics and protection requirements of your circuit.
Q: Are both parts available in the same packaging?
A: Both parts are supplied in bulk packaging and are available in active production status with confirmed inventory (2479010000: 874 pcs; 2478270000: 712 pcs).
Q: Do both parts carry the same regulatory approvals?
A: Yes. Both MCB 489 variants carry identical certifications: CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, and VDE.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts