Weidmüller 24356 Equivalent & Substitute Parts

Part Overview

The Weidmüller 24356 is a 12-circuit barrier block connector with screw termination, rated for 20A at 300V. This component is classified as obsolete, making equivalent substitute parts necessary for ongoing system maintenance and new design implementations. The barrier block configuration provides enclosed terminal protection suitable for chassis and panel mounting applications.

Substiute Parts

24356
WeidmüllerIn Stock: 96124356 Datasheet
24356
Current Part
2716127
Phoenix ContactIn Stock: 10602716127 Datasheet
2716127
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 24356
Manufacturer Weidmüller
Category Terminal Blocks
Terminal Block Type Barrier Block
Number of Circuits 12
Number of Wire Entries 24
Number of Rows 2
Current Rating 20A
Voltage Rating 300V
Wire Gauge 12-22 AWG
Top Termination Screws
Bottom Termination Closed
Barrier Type Enclosed
Mounting Type Chassis, Panel
Material - Insulation Polyamide (PA), Nylon
Color Beige
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the Weidmüller 24356 is determined by the following critical parameters:

  • Terminal block type must be barrier block with enclosed configuration
  • Circuit count must equal 12 circuits with 24 wire entries
  • Row configuration must be 2 rows
  • Top termination must be screw-based
  • Bottom termination must be closed
  • Mounting capability must support chassis and panel installation
  • Insulation material must be polyamide or nylon-based
  • Voltage rating must meet or exceed 300V

The Phoenix Contact 2716127 satisfies all substitution criteria within these allowed parameters.

Parameter Comparison

Parameter Weidmüller 24356 Phoenix Contact 2716127
Manufacturer Part Number 24356 2716127
Manufacturer Weidmüller Phoenix Contact
Terminal Block Type Barrier Block Barrier Block
Number of Circuits 12 12
Number of Wire Entries 24 24
Number of Rows 2 2
Current Rating 20A 30A
Voltage Rating 300V 300V
Wire Gauge 12-22 AWG 10-26 AWG
Top Termination Screws Screws
Bottom Termination Closed Closed
Barrier Type Enclosed Enclosed
Mounting Type Chassis, Panel Chassis, Panel
Material - Insulation Polyamide (PA), Nylon Polyamide (PA), Nylon
Product Status Obsolete Active

Engineering Selection Recommendations

The Phoenix Contact 2716127 is the qualified substitute for the Weidmüller 24356. The substitute part maintains functional equivalence across all critical parameters: identical circuit count, wire entry configuration, row structure, termination method, and barrier enclosure design.

The Phoenix Contact 2716127 offers enhanced specifications in current rating (30A versus 20A) and wire gauge range (10-26 AWG versus 12-22 AWG), providing greater design flexibility without compromising compatibility. The substitute part carries active product status with RoHS3 compliance and UL94 V-2 flammability rating, ensuring long-term availability and regulatory alignment.

Both parts maintain identical voltage rating (300V), mounting capability, and insulation material composition, confirming direct substitution feasibility for chassis and panel mounting applications.

Frequently Asked Questions (FAQ)

Q: Can the Phoenix Contact 2716127 directly replace the Weidmüller 24356?

A: Yes. Both parts share identical circuit count (12), wire entry configuration (24), row structure (2), screw termination, closed bottom termination, enclosed barrier type, and mounting capability. The substitute part meets all functional requirements for direct replacement.

Q: What are the key differences between these parts?

A: The Phoenix Contact 2716127 provides higher current rating (30A versus 20A) and broader wire gauge acceptance (10-26 AWG versus 12-22 AWG). The substitute part is active in production status with RoHS3 compliance, whereas the original Weidmüller part is obsolete.

Q: Are there packaging considerations for substitution?

A: The Weidmüller 24356 is supplied in standard packaging, while the Phoenix Contact 2716127 is available in bulk packaging. Verify packaging requirements for your procurement process.

Q: Does the color difference affect substitution?

A: Color difference (beige versus gray) does not affect electrical or mechanical compatibility. Selection should be based on visual identification requirements within your application.

Q: What compliance certifications apply to the substitute part?

A: The Phoenix Contact 2716127 carries RoHS3 compliance and UL94 V-2 flammability rating. Both parts maintain REACH unaffected status and EAR99 export classification.