Signal Transformer 241-6-36 Equivalent & Substitute Parts

Part Overview

The Signal Transformer 241-6-36 is a laminated core power transformer rated at 30VA with a 115V primary and 36V secondary output. This chassis-mount transformer is designed for applications requiring isolated 36V power delivery at up to 850mA output current. The part is currently active in production with full RoHS3 compliance and 2500Vrms isolation rating. Substitute parts are identified when equivalent electrical performance and mechanical compatibility can be maintained within the specified parameter ranges for this transformer category.

Substiute Parts

241-6-36
Signal TransformerIn Stock: 1034241-6-36 Datasheet
241-6-36
Current Part
186E36
Hammond ManufacturingIn Stock: 954186E36 Datasheet
186E36
Direct
F6-36
Triad MagneticsIn Stock: 800F6-36 Datasheet
F6-36
Direct

Key Parameters

Parameter Value
Manufacturer Part Number 241-6-36
Manufacturer Signal Transformer
Series Two-4-Oneā„¢
Type Laminated Core
Voltage - Primary 115V
Voltage - Secondary (Full Load) 36V
Current - Output (Max) 850mA
Power - Max 30VA
Primary Winding(s) Single
Secondary Winding(s) Single
Center Tap Yes
Mounting Type Chassis Mount
Termination Style Solder, Quick Connect
Voltage - Isolation 2500Vrms
RoHS Status ROHS3 Compliant
Product Status Active

Substitute Part Grouping Explanation

Substitute parts for the 241-6-36 are classified based on the following critical electrical and mechanical parameters:

Primary Substitution Criteria:

  • Secondary voltage output: 36V (fixed requirement)
  • Mounting type: Chassis Mount (fixed requirement)
  • Center tap configuration: Yes (fixed requirement)
  • Termination style: Solder and Quick Connect compatible
  • Laminated core construction
  • RoHS3 compliance and active product status

Allowable Parameter Variations:

  • Primary voltage: 115V or dual voltage (115V/230V) configurations are acceptable
  • Power rating: Equal to or greater than 30VA
  • Output current: Equal to or greater than 850mA
  • Isolation voltage: Equal to or greater than 2500V
  • Physical dimensions: Variations within chassis mount envelope constraints

The 241-6-36 has two identified substitutes: the Hammond Manufacturing 186E36 and the Triad Magnetics F6-36. The F6-36 maintains identical electrical specifications and power rating. The 186E36 offers increased power capacity (54VA) and dual primary voltage capability while maintaining the core 36V secondary output and center tap configuration.

Parameter Comparison

Parameter 241-6-36 (Signal Transformer) F6-36 (Triad Magnetics) 186E36 (Hammond Manufacturing)
Voltage - Primary 115V 115V 115V, 230V
Voltage - Secondary (Full Load) 36V 36V 36V
Current - Output (Max) 850mA 850mA 1.5A
Power - Max 30VA 30VA 54VA
Primary Winding(s) Single Single Dual
Secondary Winding(s) Single Single Single
Center Tap Yes Yes Yes
Type Laminated Core Laminated Core Laminated Core
Mounting Type Chassis Mount Chassis Mount Chassis Mount
Termination Style Solder, Quick Connect Solder, Quick Connect - 0.187" (4.7mm) Solder, Quick Connect
Voltage - Isolation 2500Vrms 2500VAC 2000Vrms
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Product Status Active Active Active

Engineering Selection Recommendations

All three transformers maintain active product status with full RoHS3 compliance and REACH unaffected designation. Selection between the 241-6-36, F6-36, and 186E36 depends on application-specific requirements:

241-6-36 (Signal Transformer): Direct selection when 30VA power capacity and 850mA output current are specified. Maintains 2500Vrms isolation rating.

F6-36 (Triad Magnetics): Direct electrical equivalent with identical 30VA rating and 850mA output current. Maintains 2500VAC isolation rating. Suitable for applications with identical power and current requirements. Quick Connect termination specified as 0.187" (4.7mm).

186E36 (Hammond Manufacturing): Selection when higher power capacity (54VA) or dual primary voltage operation (115V/230V) is required. Supports up to 1.5A output current. Isolation rating of 2000Vrms is lower than the primary part but remains suitable for standard industrial applications. Dual primary winding enables operation across different regional power standards.

Frequently Asked Questions (FAQ)

Q: Can the 186E36 replace the 241-6-36 in all applications?

A: The 186E36 is electrically compatible for applications requiring 36V secondary output with center tap configuration. The higher power rating (54VA vs. 30VA) and increased output current capability (1.5A vs. 850mA) make it suitable for applications demanding equal or lesser power. The dual primary voltage capability adds operational flexibility. The isolation voltage is 2000Vrms compared to 2500Vrms on the original part; verify isolation requirements for your specific application.

Q: What is the difference between the F6-36 and 241-6-36?

A: The F6-36 and 241-6-36 are electrically identical with matching 30VA power ratings, 850mA output current, and 36V secondary voltage. Both feature single primary and secondary windings with center tap configuration. The primary difference is manufacturer (Triad Magnetics vs. Signal Transformer). The F6-36 specifies Quick Connect termination as 0.187" (4.7mm). Both maintain 2500V isolation rating and RoHS3 compliance.

Q: Are the physical dimensions compatible for chassis mount applications?

A: The 241-6-36 measures 82.60mm L x 44.30mm W x 49.80mm H. The F6-36 measures 82.55mm L x 42.85mm W x 49.20mm H, providing nearly identical footprint. The 186E36 is larger at 93.47mm L x 45.97mm W x 57.15mm H. Verify available chassis space before selecting the 186E36 as a substitute in existing designs.

Q: Do all three transformers support the same termination methods?

A: All three transformers support Solder and Quick Connect termination styles. The F6-36 specifies Quick Connect as 0.187" (4.7mm). Verify connector compatibility with your existing wiring harness or PCB design before substitution.

Q: What is the weight difference between these transformers?

A: The 241-6-36 and F6-36 both weigh 1.1 lbs (499 g). The 186E36 weighs 1.8 lbs (816.5 g) due to its higher power rating and larger core. Consider weight impact in applications with strict mass constraints.

Request Quote (Ships tomorrow)