Phoenix Contact 2300096 SSR Relay SPST-NO 3A 3-33V Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 2300096 is a solid-state relay (SSR) module with SPST-NO (1 Form A) configuration, rated for 3A load current and 3-33V DC output voltage. This component is classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing system maintenance and new design implementations. The through-hole PC pin termination and module package form factor define its primary application context.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2300096 |
| Manufacturer | Phoenix Contact |
| Series | SIM-EI |
| Circuit Configuration | SPST-NO (1 Form A) |
| Output Type | DC |
| Input Voltage | 24VDC |
| Load Voltage Range | 3 V ~ 33 V |
| Load Current Rating | 3 A |
| Mounting Type | Through Hole |
| Termination Style | PC Pin |
| Package / Case | Module |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
| MSL Rating | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 2300096 is determined by the following critical parameters:
- Circuit configuration: SPST-NO (1 Form A) topology
- Output type: DC switching capability
- Input voltage: 24VDC control signal
- Load voltage range: 3 V ~ 33 V DC
- Load current capacity: 3 A minimum rating
- Electrical isolation and switching characteristics
The Phoenix Contact 2966595 qualifies as a functional equivalent based on matching all critical electrical parameters. While the mounting type and termination style differ (socketable 4-SIP plug-in versus through-hole PC pin), the electrical performance envelope remains identical, permitting substitution in applications where mechanical form factor constraints do not apply.
Parameter Comparison
| Parameter | 2300096 (Main Part) | 2966595 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Circuit Configuration | SPST-NO (1 Form A) | SPST-NO (1 Form A) |
| Output Type | DC | DC |
| Input Voltage | 24VDC | 24VDC |
| Load Voltage Range | 3 V ~ 33 V | 3 V ~ 33 V |
| Load Current Rating | 3 A | 3 A |
| Mounting Type | Through Hole | Socketable |
| Termination Style | PC Pin | Plug In |
| Package / Case | Module | 4-SIP |
| Series | SIM-EI | OPT |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The Phoenix Contact 2966595 is the primary substitute for the obsolete 2300096. Both components share identical electrical specifications across all critical parameters: 24VDC input, 3-33V DC load voltage range, and 3A load current capacity with SPST-NO switching topology.
The 2966595 holds active product status with ROHS3 compliance, providing supply chain continuity and regulatory alignment for new designs and system replacements. The socketable 4-SIP package with plug-in termination represents the mechanical differentiation; this configuration is suitable for applications permitting modular insertion without direct PCB soldering.
For applications requiring through-hole PC pin termination identical to the original 2300096, mechanical redesign or adapter solutions may be necessary. The electrical performance equivalence remains absolute regardless of mounting methodology.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 2966595 directly replace the 2300096 in existing PCB designs?
A: Electrical substitution is complete. Mechanical compatibility depends on the PCB socket configuration. The 2300096 uses through-hole PC pins for direct soldering; the 2966595 requires a 4-SIP socket. PCB modification or adapter hardware may be required.
Q: What are the critical parameters that define substitution eligibility?
A: Substitution is valid when the following parameters match: SPST-NO circuit configuration, DC output type, 24VDC input voltage, 3-33V load voltage range, and 3A load current rating. All these parameters are identical between the 2300096 and 2966595.
Q: Why is the 2300096 listed as obsolete?
A: The 2300096 is classified as obsolete by Phoenix Contact. The 2966595 from the active OPT series provides equivalent electrical functionality with current manufacturing and supply availability.
Q: Are there compliance differences between the two parts?
A: Both components are RoHS compliant. The 2966595 carries ROHS3 certification, representing the current regulatory standard. The 2300096 holds RoHS Compliant status. Both maintain MSL 1 (Unlimited) moisture sensitivity ratings.
Q: What is the primary mechanical difference between these SSR relays?
A: The 2300096 features through-hole PC pin termination in a module package. The 2966595 uses socketable 4-SIP plug-in termination. This affects PCB integration methodology but does not alter electrical performance or switching characteristics.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts