SCHURTER 2040.0710 Equivalent & Substitute Parts

Part Overview

The SCHURTER 2040.0710 is a 315 mA, 250 V AC board mount fuse with radial, can, vertical package configuration. This component is classified as obsolete, necessitating identification of active equivalent alternatives for new designs and ongoing production requirements. The part operates across a temperature range of -40°C to 85°C and meets multiple international compliance standards including CCC, cURus, and VDE certifications.

Substiute Parts

2040.0710
SCHURTER Inc.In Stock: 10532040.0710 Datasheet
2040.0710
Current Part
0034.6710
SCHURTER Inc.In Stock: 21310034.6710 Datasheet
0034.6710
Direct
0034.7110
SCHURTER Inc.In Stock: 12340034.7110 Datasheet
0034.7110
Parametric Equivalent
0034.7210
SCHURTER Inc.In Stock: 8650034.7210 Datasheet
0034.7210
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 315 mA
Voltage Rating - AC 250 V
Response Time Slow Blow
Mounting Type Through Hole
Package / Case Radial, Can, Vertical
Size / Dimension 0.335" Dia x 0.335" H (8.50mm x 8.50mm)
Breaking Capacity @ Rated Voltage 35A
Melting I²t 0.8
Operating Temperature -40°C ~ 85°C
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the 2040.0710 are qualified based on the following critical parameters:

  • Current Rating: 315 mA (exact match required)
  • Voltage Rating - AC: 250 V (exact match required)
  • Response Time: Slow Blow (exact match required)
  • Mounting Type: Through Hole (exact match required)
  • Package / Case: Radial, Can, Vertical (exact match required)
  • Size / Dimension: 0.335" Dia x 0.335" H (8.50mm x 8.50mm) (exact match required)

Three active substitute parts meet these core electrical and mechanical parameters while offering improved product status and expanded compliance certifications.

Parameter Comparison

Parameter 2040.0710 (Main) 0034.6710 0034.7110 0034.7210
Manufacturer SCHURTER Inc. SCHURTER Inc. SCHURTER Inc. SCHURTER Inc.
Current Rating (Amps) 315 mA 315 mA 315 mA 315 mA
Voltage Rating - AC 250 V 250 V 250 V 250 V
Voltage Rating - DC Not specified 125 V Not specified Not specified
Response Time Slow Blow Slow Blow Slow Blow Slow Blow
Mounting Type Through Hole Through Hole Through Hole Through Hole
Package / Case Radial, Can, Vertical Radial, Can, Vertical Radial, Can, Vertical Radial, Can, Vertical
Size / Dimension 0.335" Dia x 0.335" H (8.50mm x 8.50mm) 0.335" Dia x 0.335" H (8.50mm x 8.50mm) 0.335" Dia x 0.335" H (8.50mm x 8.50mm) 0.335" Dia x 0.335" H (8.50mm x 8.50mm)
Breaking Capacity @ Rated Voltage 35A 35A AC, 50A DC 50A 50A
Melting I²t 0.8 0.8 0.361 0.361
Operating Temperature -40°C ~ 85°C -55°C ~ 125°C -40°C ~ 85°C -40°C ~ 85°C
Product Status Obsolete Active Active Active
Series MSU 250 MST 250 MSTU 250 MSTU 250
Approval Agency CCC, cURus, VDE CCC, cURus, KC, VDE cULus cULus
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

All three substitute parts (0034.6710, 0034.7110, 0034.7210) satisfy the core electrical and mechanical requirements of the 2040.0710. Selection among these alternatives depends on specific application requirements:

0034.6710 provides dual voltage capability with 125 V DC rating and expanded temperature range (-55°C to 125°C), making it suitable for applications requiring DC circuit protection or extended thermal operating conditions. This part carries the broadest compliance certification set including CCC, cURus, KC, and VDE.

0034.7110 and 0034.7210 are functionally equivalent alternatives from the MSTU 250 series with identical electrical characteristics, operating temperature range, and cULus certification. These parts feature increased breaking capacity (50A versus 35A) and reduced melting I²t (0.361 versus 0.8), indicating faster response characteristics. Both parts maintain active product status with confirmed inventory availability.

All substitute parts maintain ROHS3 compliance and REACH unaffected status consistent with the original component.

Frequently Asked Questions (FAQ)

Q: Can 0034.6710 be used in AC-only circuits? A: Yes. The 0034.6710 maintains the 250 V AC rating required for the original application. The additional 125 V DC rating does not restrict AC circuit operation.

Q: What is the significance of the different melting I²t values? A: Melting I²t characterizes the thermal energy required to melt the fuse element. The 0034.6710 with I²t of 0.8 matches the original 2040.0710 characteristic. The 0034.7110 and 0034.7210 with I²t of 0.361 respond faster to overcurrent conditions, providing more sensitive protection.

Q: Are the physical dimensions identical across all substitute parts? A: Yes. All substitute parts maintain the 0.335" diameter by 0.335" height (8.50mm x 8.50mm) radial, can, vertical package configuration, ensuring direct mechanical compatibility.

Q: Which substitute part offers the widest operating temperature range? A: The 0034.6710 operates across -55°C to 125°C, compared to -40°C to 85°C for the original part and both MSTU 250 series alternatives.

Q: Do all substitute parts carry the same compliance certifications as the original? A: No. The 0034.6710 carries CCC, cURus, KC, and VDE certifications. The 0034.7110 and 0034.7210 carry cULus certification only. Application requirements determine which certification set is necessary.

Request Quote (Ships tomorrow)