Equivalent & Substitute Parts for Bourns 2037-35-CLF

Part Overview

The Bourns 2037-35-CLF is a Gas Discharge Tube (GDT) rated for 350V DC spark-over voltage with 5000A (5kA) impulse discharge current capacity in a 2-pole through-hole configuration. This component is classified as obsolete, necessitating identification of active equivalent parts for continued system design and procurement. The 2037-35-CLF maintains ROHS3 compliance and is suitable for overvoltage protection applications requiring axial cylinder package geometry.

Substiute Parts

2037-35-CLF
Bourns Inc.In Stock: 10472037-35-CLF Datasheet
2037-35-CLF
Current Part
2037-35-BLF
Bourns Inc.In Stock: 53962037-35-BLF Datasheet
2037-35-BLF
Direct

Key Parameters

Parameter Value
Manufacturer Part Number 2037-35-CLF
Manufacturer Bourns Inc.
Series 2037
Voltage - DC Spark Over (Nominal) 350 V
Impulse Discharge Current (8/20µs) 5000A (5kA)
Tolerance ±15%
Number of Poles 2
Mounting Type Through Hole
Package / Case Axial Cylinder
Fail Short No
RoHS Status ROHS3 Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

The 2037-35-BLF qualifies as a direct substitute for the 2037-35-CLF based on identical electrical and mechanical parameters. Substitution is valid when the following criteria are met:

  • Voltage - DC Spark Over (Nominal): 350 V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
  • Fail Short characteristic: No

The primary distinction between these parts is product status and packaging configuration. The 2037-35-CLF is obsolete with tape-and-reel packaging, while the 2037-35-BLF is active with bulk packaging.

Parameter Comparison

Parameter 2037-35-CLF (Main Part) 2037-35-BLF (Substitute)
Manufacturer Bourns Inc. Bourns Inc.
Series 2037 2037
Voltage - DC Spark Over (Nominal) 350 V 350 V
Impulse Discharge Current (8/20µs) 5000A (5kA) 5000A (5kA)
Tolerance ±15% ±15%
Number of Poles 2 2
Mounting Type Through Hole Through Hole
Package / Case Axial Cylinder Axial Cylinder
Fail Short No No
RoHS Status ROHS3 Compliant ROHS3 Compliant
Product Status Obsolete Active
Packaging Type Tape and Reel (CLF) Bulk (BLF)

Engineering Selection Recommendations

The 2037-35-BLF is the direct functional equivalent for the obsolete 2037-35-CLF. Both parts share identical electrical specifications (350V DC spark-over, 5kA impulse discharge current) and mechanical configuration (2-pole, through-hole, axial cylinder package). The 2037-35-BLF maintains active product status and full ROHS3 compliance, making it suitable for new designs and procurement requiring replacement of the obsolete 2037-35-CLF. Packaging differences (bulk versus tape-and-reel) do not affect electrical or mechanical compatibility and are determined by procurement volume and assembly requirements.

Frequently Asked Questions (FAQ)

Q: Can the 2037-35-BLF directly replace the 2037-35-CLF in existing designs?

A: Yes. Both parts are electrically and mechanically identical, with matching 350V DC spark-over voltage, 5kA impulse discharge current, 2-pole configuration, and through-hole axial cylinder package. The 2037-35-BLF is the active equivalent.

Q: What is the difference between CLF and BLF packaging designations?

A: CLF indicates tape-and-reel packaging, while BLF indicates bulk packaging. Both contain the same Gas Discharge Tube component. Selection depends on assembly process requirements and order quantities.

Q: Are there any compliance differences between these parts?

A: No. Both the 2037-35-CLF and 2037-35-BLF maintain identical ROHS3 compliance status and are REACH Unaffected.

Q: Why is the 2037-35-CLF listed as obsolete?

A: Product obsolescence is determined by manufacturer lifecycle decisions. The 2037-35-BLF remains in active production with identical specifications, providing continuity for applications requiring this GDT specification.

Q: Are the electrical characteristics guaranteed to be identical between these parts?

A: Yes. Both parts share identical nominal specifications: 350V DC spark-over voltage, 5000A (5kA) impulse discharge current at 8/20µs, ±15% tolerance, and 2-pole configuration.

Request Quote (Ships tomorrow)