Bourns 2036-30-C2 Gas Discharge Tube: Equivalent & Substitute Parts

Part Overview

The Bourns 2036-30-C2 is a 3-pole gas discharge tube (GDT) rated for 300V DC spark-over voltage with 10kA impulse discharge current capacity. This component is designed for overvoltage protection in telecommunications and industrial applications. The 2036-30-C2 is classified as obsolete, making identification of active equivalent parts essential for ongoing procurement and system maintenance.

Substiute Parts

2036-30-C2
Bourns Inc.In Stock: 8262036-30-C2 Datasheet
2036-30-C2
Current Part
2036-30-B2
Bourns Inc.In Stock: 9252036-30-B2 Datasheet
2036-30-B2
Direct

Key Parameters

Parameter Value
Voltage - DC Spark Over (Nominal) 300 V
Impulse Discharge Current (8/20µs) 10000A (10kA)
Tolerance ±20%
Number of Poles 3
Fail Short No
Mounting Type Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend)
Series Mini-TRIGARD™ 2036

Substitute Part Grouping Explanation

Substitution of the 2036-30-C2 is determined by strict equivalence across the following electrical and mechanical parameters:

  • Voltage - DC Spark Over (Nominal): 300 V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short characteristic: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
  • Series: Mini-TRIGARD™ 2036

The 2036-30-B2 meets all specified electrical and mechanical requirements for direct substitution. The primary distinction between these parts is product status and packaging configuration.

Parameter Comparison

Parameter 2036-30-C2 (Main Part) 2036-30-B2 (Substitute)
Manufacturer Bourns Inc. Bourns Inc.
Series Mini-TRIGARD™ 2036 Mini-TRIGARD™ 2036
Voltage - DC Spark Over (Nominal) 300 V 300 V
Impulse Discharge Current (8/20µs) 10000A (10kA) 10000A (10kA)
Tolerance ±20% ±20%
Number of Poles 3 3
Fail Short No No
Mounting Type Through Hole Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend) Axial Cylinder, 3 Lead (Radial Bend)
Product Status Obsolete Active
Packaging Bulk Tray
RoHS Status RoHS non-compliant RoHS non-compliant
REACH Status REACH Affected REACH Affected
ECCN EAR99 EAR99
HTSUS 8536.30.8000 8536.30.8000

Engineering Selection Recommendations

The 2036-30-B2 is the direct functional equivalent to the 2036-30-C2. Both components share identical electrical specifications and mechanical form factors. The 2036-30-B2 carries active product status, ensuring continued availability and supply chain stability. Both parts maintain equivalent compliance profiles under RoHS and REACH regulations. Selection between these parts should be based on packaging requirements: the 2036-30-C2 is supplied in bulk packaging, while the 2036-30-B2 is supplied in tray packaging.

Frequently Asked Questions (FAQ)

Q: Can the 2036-30-B2 directly replace the 2036-30-C2 in existing designs?

A: Yes. Both parts are electrically and mechanically identical, with matching voltage ratings, discharge current capacity, pole configuration, and through-hole mounting specifications.

Q: What is the difference between these two part numbers?

A: The primary differences are product status and packaging. The 2036-30-C2 is obsolete and supplied in bulk packaging. The 2036-30-B2 is active and supplied in tray packaging.

Q: Are there any compliance differences between these parts?

A: No. Both parts share identical RoHS, REACH, ECCN, and HTSUS classifications.

Q: Does packaging affect electrical performance?

A: No. Packaging configuration does not alter electrical or mechanical performance. Selection should be based on procurement and assembly workflow requirements.

Q: What parameters must remain constant for substitution?

A: Voltage rating (300V), discharge current (10kA), pole count (3), fail-short characteristic (No), mounting type (Through Hole), and package form factor (Axial Cylinder, 3 Lead Radial Bend) must all remain unchanged for functional equivalence.