Equivalent & Substitute Parts for Bourns 2036-20-C2 Gas Discharge Tube
Part Overview
The Bourns 2036-20-C2 is a Gas Discharge Tube (GDT) rated for 200V DC spark-over voltage with 10kA impulse discharge current capacity in a 3-pole through-hole configuration. This component is classified as obsolete, making identification of suitable substitutes essential for ongoing system support and component procurement. The 2036-20-C2 belongs to the Mini-TRIGARD™ 2036 series and is designed for transient overvoltage protection applications requiring multi-pole surge suppression.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 2036-20-C2 |
| Manufacturer | Bourns Inc. |
| Series | Mini-TRIGARD™ 2036 |
| Voltage - DC Spark Over (Nominal) | 200 V |
| Impulse Discharge Current (8/20µs) | 10000A (10kA) |
| Tolerance | ±20% |
| Number of Poles | 3 |
| Fail Short | No |
| Mounting Type | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) |
| Product Status | Obsolete |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Affected |
Substitute Part Grouping Explanation
Substitution eligibility for the 2036-20-C2 is determined by strict equivalence across the following critical parameters:
- Voltage - DC Spark Over (Nominal): 200 V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 3
- Fail Short characteristic: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
- Series: Mini-TRIGARD™ 2036
The 2036-20-B2 qualifies as a direct substitute based on identical electrical specifications and mechanical form factor. The primary distinction between these parts is product status and packaging configuration.
Parameter Comparison
| Parameter | 2036-20-C2 (Main Part) | 2036-20-B2 (Substitute) |
|---|---|---|
| Manufacturer Part Number | 2036-20-C2 | 2036-20-B2 |
| Manufacturer | Bourns Inc. | Bourns Inc. |
| Series | Mini-TRIGARD™ 2036 | Mini-TRIGARD™ 2036 |
| Voltage - DC Spark Over (Nominal) | 200 V | 200 V |
| Impulse Discharge Current (8/20µs) | 10000A (10kA) | 10000A (10kA) |
| Tolerance | ±20% | ±20% |
| Number of Poles | 3 | 3 |
| Fail Short | No | No |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) | Axial Cylinder, 3 Lead (Radial Bend) |
| Product Status | Obsolete | Active |
| Packaging | Bulk | Tray |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Affected | REACH Affected |
Engineering Selection Recommendations
The 2036-20-B2 is the direct equivalent for the obsolete 2036-20-C2. Both components share identical electrical performance characteristics (200V spark-over, 10kA impulse current) and mechanical specifications (3-pole through-hole, axial cylinder package). The 2036-20-B2 maintains active product status, ensuring continued availability and supply chain reliability. Both parts carry identical compliance designations (RoHS non-compliant, REACH Affected). The substitution is electrically and mechanically transparent for circuit applications currently using the 2036-20-C2.
Frequently Asked Questions (FAQ)
Q: Can the 2036-20-B2 be used as a direct replacement for the 2036-20-C2 in existing designs?
A: Yes. The 2036-20-B2 is electrically and mechanically equivalent to the 2036-20-C2. Both components have identical spark-over voltage (200V), impulse discharge current (10kA), pole configuration (3-pole), and through-hole mounting specifications. No circuit modifications are required.
Q: What is the difference between the 2036-20-C2 and 2036-20-B2?
A: The primary differences are product status and packaging. The 2036-20-C2 is obsolete and supplied in bulk packaging, while the 2036-20-B2 is active and supplied in tray packaging. All electrical and mechanical parameters are identical.
Q: Are there any compliance differences between these parts?
A: No. Both the 2036-20-C2 and 2036-20-B2 share identical RoHS and REACH compliance status (RoHS non-compliant, REACH Affected). Compliance considerations do not differentiate these substitutes.
Q: Does the packaging difference (bulk vs. tray) affect component performance?
A: No. Packaging format does not affect electrical or mechanical performance. The difference is logistical only and relates to component handling and storage during distribution.
Q: What parameters must remain constant for substitution eligibility?
A: Substitution requires equivalence in voltage rating (200V), impulse current capacity (10kA), tolerance (±20%), pole count (3), fail-short characteristic (No), mounting type (through-hole), and package form factor (axial cylinder, 3-lead radial bend).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts