Bourns 2036-07-C3 Gas Discharge Tube: Equivalent & Substitute Parts
Part Overview
The Bourns 2036-07-C3 is a 3-pole gas discharge tube (GDT) rated for 75V DC spark-over voltage with 10kA impulse discharge current capacity. This component is designed for surge protection applications requiring through-hole mounting in axial cylinder configuration. The 2036-07-C3 is classified as obsolete, making identification of equivalent substitute parts essential for ongoing system support and procurement planning.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Voltage - DC Spark Over (Nominal) | 75 V |
| Impulse Discharge Current (8/20µs) | 10000A (10kA) |
| Tolerance | ±20% |
| Number of Poles | 3 |
| Mounting Type | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) |
| Fail Short | No |
| Series | Mini-TRIGARD™ 2036 |
Substitute Part Grouping Explanation
Substitution for the 2036-07-C3 is determined by electrical and mechanical parameter equivalence within the Mini-TRIGARD™ 2036 series. The substitute part must match the following critical parameters:
- Voltage - DC Spark Over (Nominal): 75 V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 3
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
- Fail Short characteristic: No
The primary difference between the main part and its substitute relates to product status and packaging configuration, not electrical or mechanical performance.
Parameter Comparison
| Parameter | 2036-07-C3 (Main) | 2036-07-B3 (Substitute) |
|---|---|---|
| Manufacturer | Bourns Inc. | Bourns Inc. |
| Series | Mini-TRIGARD™ 2036 | Mini-TRIGARD™ 2036 |
| Voltage - DC Spark Over (Nominal) | 75 V | 75 V |
| Impulse Discharge Current (8/20µs) | 10000A (10kA) | 10000A (10kA) |
| Tolerance | ±20% | ±20% |
| Number of Poles | 3 | 3 |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) | Axial Cylinder, 3 Lead (Radial Bend) |
| Fail Short | No | No |
| Product Status | Obsolete | Active |
| Packaging | Bulk | Tray |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Affected | REACH Affected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.30.8000 | 8536.30.8000 |
Engineering Selection Recommendations
The 2036-07-B3 is the direct substitute for the obsolete 2036-07-C3. Both parts are electrically and mechanically identical, with all critical parameters matching exactly. The 2036-07-B3 maintains active product status, ensuring continued availability and supply chain support. Both parts carry identical compliance classifications (RoHS non-compliant, REACH Affected, ECCN EAR99). The only operational difference is packaging format: the 2036-07-C3 ships in bulk, while the 2036-07-B3 is supplied in tray packaging. This packaging difference does not affect electrical performance or mechanical fit in through-hole applications.
Frequently Asked Questions (FAQ)
Q: Can the 2036-07-B3 directly replace the 2036-07-C3 in existing designs?
A: Yes. The 2036-07-B3 is electrically and mechanically equivalent to the 2036-07-C3. All electrical parameters (75V spark-over, 10kA discharge current, ±20% tolerance) and mechanical specifications (3-pole, through-hole, axial cylinder package) are identical. Direct substitution is valid for all applications.
Q: What is the difference between the 2036-07-C3 and 2036-07-B3?
A: The parts differ only in product status and packaging. The 2036-07-C3 is obsolete and supplied in bulk packaging. The 2036-07-B3 is active and supplied in tray packaging. Electrical and mechanical performance are identical.
Q: Does the tray packaging of the 2036-07-B3 affect installation?
A: No. Packaging format does not affect component performance or mechanical fit. Both parts use the same axial cylinder, 3-lead radial bend package configuration suitable for through-hole mounting.
Q: Are there compliance differences between these parts?
A: No. Both parts carry identical compliance designations: RoHS non-compliant, REACH Affected, ECCN EAR99, and HTSUS 8536.30.8000.
Q: Why is the 2036-07-C3 obsolete?
A: Product status information is not provided in the technical data. Consult Bourns Inc. directly for obsolescence details and lifecycle information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts