Equivalent & Substitute Parts for Bourns 2036-07-C2LF Gas Discharge Tube

Part Overview

The Bourns 2036-07-C2LF is a Gas Discharge Tube (GDT) rated for 75V DC spark-over voltage with 10kA impulse discharge current capacity in a 3-pole through-hole configuration. This component is classified as Obsolete, making identification of functionally equivalent alternatives essential for ongoing system support and procurement planning. The 2036-07-B2LF serves as the direct substitute, offering identical electrical performance with current market availability.

Substiute Parts

2036-07-C2LF
Bourns Inc.In Stock: 11582036-07-C2LF Datasheet
2036-07-C2LF
Current Part
2036-07-B2LF
Bourns Inc.In Stock: 104582036-07-B2LF Datasheet
2036-07-B2LF
Similar

Key Parameters

Parameter Value
Voltage - DC Spark Over (Nominal) 75 V
Impulse Discharge Current (8/20µs) 10000A (10kA)
Tolerance ±20%
Number of Poles 3
Mounting Type Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend)
Fail Short No
Series Mini-TRIGARD™ 2036

Substitute Part Grouping Explanation

The 2036-07-B2LF qualifies as a direct substitute based on matching all critical electrical and mechanical parameters:

  • Identical DC spark-over voltage: 75V nominal
  • Identical impulse discharge current rating: 10kA (8/20µs)
  • Identical tolerance specification: ±20%
  • Identical pole configuration: 3-pole
  • Identical mounting technology: Through-hole
  • Identical package geometry: Axial Cylinder, 3 Lead (Radial Bend)
  • Identical fail-short characteristic: No
  • Same product series: Mini-TRIGARD™ 2036

The substitution is valid across all specified electrical and mechanical dimensions.

Parameter Comparison

Parameter 2036-07-C2LF (Main) 2036-07-B2LF (Substitute)
Manufacturer Bourns Inc. Bourns Inc.
Series Mini-TRIGARD™ 2036 Mini-TRIGARD™ 2036
Voltage - DC Spark Over (Nom) 75 V 75 V
Impulse Discharge Current (8/20µs) 10000A (10kA) 10000A (10kA)
Tolerance ±20% ±20%
Number of Poles 3 3
Mounting Type Through Hole Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend) Axial Cylinder, 3 Lead (Radial Bend)
Fail Short No No
Product Status Obsolete Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

The 2036-07-B2LF is the appropriate selection for applications currently using the 2036-07-C2LF. Both components maintain identical electrical performance specifications and mechanical compatibility. The substitute part carries Active product status, ensuring long-term availability and supply chain continuity. Both parts maintain equivalent regulatory compliance: ROHS3 Compliant and REACH Unaffected status. The transition from the obsolete 2036-07-C2LF to the 2036-07-B2LF requires no circuit redesign or application modification.

Frequently Asked Questions (FAQ)

Q: Can the 2036-07-B2LF directly replace the 2036-07-C2LF in existing designs?

A: Yes. Both parts are electrically and mechanically identical across all specified parameters. No circuit modifications are required.

Q: What is the difference between these two part numbers?

A: The primary difference is product status and packaging. The 2036-07-C2LF is Obsolete, while the 2036-07-B2LF is Active. The 2036-07-B2LF is supplied in Tray packaging, whereas the 2036-07-C2LF packaging specification was not provided.

Q: Are there any compliance differences between these parts?

A: No. Both parts maintain identical RoHS3 Compliance and REACH Unaffected status.

Q: Will PCB layout or footprint require changes?

A: No. Both components use the same package geometry: Axial Cylinder, 3 Lead (Radial Bend) through-hole configuration.

Q: What is the impulse discharge current rating, and why is it important?

A: Both parts are rated for 10kA (10000A) impulse discharge current at 8/20µs waveform. This rating determines the maximum transient energy the component can safely dissipate during a surge event.

Request Quote (Ships tomorrow)