Bourns 2028-23-C2LF Gas Discharge Tube - Equivalent & Substitute Parts

Part Overview

The Bourns 2028-23-C2LF is a 3-pole gas discharge tube (GDT) rated for 230V DC spark-over voltage with 20kA impulse discharge current capacity. This component is designed for through-hole mounting in axial cylinder configuration with radial bend leads. The 2028-23-C2LF is currently listed as obsolete product status, making identification of functionally equivalent alternatives necessary for ongoing design support and procurement planning.

Substiute Parts

2028-23-C2LF
Bourns Inc.In Stock: 7802028-23-C2LF Datasheet
2028-23-C2LF
Current Part
2026-23-C2LF
Bourns Inc.In Stock: 14342026-23-C2LF Datasheet
2026-23-C2LF
Direct

Key Parameters

Parameter Value
Voltage - DC Spark Over (Nominal) 230 V
Impulse Discharge Current (8/20µs) 20000A (20kA)
Tolerance ±20%
Number of Poles 3
Fail Short No
Mounting Type Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend)
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the 2028-23-C2LF is determined by matching the following critical electrical and mechanical parameters:

  • Voltage - DC Spark Over (Nominal): 230 V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short characteristic: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)

The substitute part 2026-23-C2LF meets all specified parameters and represents an active product alternative within the Bourns TRIGARD® 2026 series.

Parameter Comparison

Parameter 2028-23-C2LF (Main Part) 2026-23-C2LF (Substitute)
Manufacturer Bourns Inc. Bourns Inc.
Series 2028 TRIGARD® 2026
Product Status Obsolete Active
Voltage - DC Spark Over (Nominal) 230 V 230 V
Impulse Discharge Current (8/20µs) 20000A (20kA) 20000A (20kA)
Tolerance ±20% ±20%
Number of Poles 3 3
Fail Short No No
Mounting Type Through Hole Through Hole
Package / Case Axial Cylinder, 3 Lead (Radial Bend) Axial Cylinder, 3 Lead (Radial Bend)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.30.8000 8536.30.8000

Engineering Selection Recommendations

The 2026-23-C2LF serves as the direct substitute for the obsolete 2028-23-C2LF. Both components share identical electrical specifications (230V spark-over, 20kA impulse discharge current) and mechanical configuration (3-pole through-hole axial cylinder package). The 2026-23-C2LF maintains active product status within the Bourns TRIGARD® 2026 series and carries equivalent compliance certifications (ROHS3, REACH Unaffected, EAR99). Selection of the 2026-23-C2LF eliminates obsolescence risk while preserving full functional compatibility in circuit protection applications requiring 230V three-pole gas discharge tube performance.

Frequently Asked Questions (FAQ)

Q: Can the 2026-23-C2LF directly replace the 2028-23-C2LF in existing designs?

A: Yes. Both components share identical electrical ratings (230V spark-over, 20kA impulse discharge current, ±20% tolerance), pole configuration (3-pole), and mechanical package (axial cylinder, 3-lead radial bend through-hole mounting). No circuit modifications are required.

Q: What is the difference between the 2028 and 2026 series?

A: The 2028 series is obsolete. The 2026 series (TRIGARD® 2026) represents the active product line from Bourns Inc. with equivalent electrical and mechanical specifications for this voltage and current rating.

Q: Are there packaging differences between these parts?

A: The main part (2028-23-C2LF) is supplied in standard packaging, while the substitute (2026-23-C2LF) is supplied in tray packaging. Both maintain the same axial cylinder, 3-lead radial bend through-hole component form factor.

Q: Do both parts meet the same compliance standards?

A: Yes. Both the 2028-23-C2LF and 2026-23-C2LF are ROHS3 compliant, REACH unaffected, and classified under ECCN EAR99 with HTSUS code 8536.30.8000.

Q: What is the impulse discharge current specification?

A: Both components are rated for 20000A (20kA) impulse discharge current at 8/20 microsecond waveform, with ±20% tolerance.