Bourns 2026-35-ALF Gas Discharge Tube (GDT) 350V 20kA 3-Pole Equivalent & Substitute Parts

Part Overview

The Bourns 2026-35-ALF is a Gas Discharge Tube (GDT) rated for 350V DC spark-over voltage with 20kA impulse discharge current capacity in a 3-pole configuration. This component is classified as obsolete, necessitating identification of active equivalent alternatives for new designs and ongoing system support. The TRIGARD® 2026 series provides direct functional substitutes with identical electrical and mechanical specifications.

Substiute Parts

2026-35-ALF
Bourns Inc.In Stock: 8032026-35-ALF Datasheet
2026-35-ALF
Current Part
2026-35-A1LF
Bourns Inc.In Stock: 8832026-35-A1LF Datasheet
2026-35-A1LF
Similar

Key Parameters

Parameter Value
Voltage - DC Spark Over (Nominal) 350 V
Impulse Discharge Current (8/20µs) 20000A (20kA)
Tolerance ±20%
Number of Poles 3
Fail Short No
Package / Case Cylinder No Lead, 3 Terminal
Mounting Type User Defined
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the 2026-35-ALF is determined by strict equivalence across the following critical parameters:

  • Voltage - DC Spark Over (Nominal): 350 V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short characteristic: No
  • Package / Case: Cylinder No Lead, 3 Terminal
  • Mounting Type: User Defined
  • RoHS and regulatory compliance status

The substitute part 2026-35-A1LF meets all these criteria and belongs to the same TRIGARD® 2026 series, making it a direct functional equivalent.

Parameter Comparison

Parameter 2026-35-ALF (Main Part) 2026-35-A1LF (Substitute)
Manufacturer Bourns Inc. Bourns Inc.
Series TRIGARD® 2026 TRIGARD® 2026
Product Status Obsolete Active
Voltage - DC Spark Over (Nom) 350 V 350 V
Impulse Discharge Current (8/20µs) 20000A (20kA) 20000A (20kA)
Tolerance ±20% ±20%
Number of Poles 3 3
Fail Short No No
Package / Case Cylinder No Lead, 3 Terminal Cylinder No Lead, 3 Terminal
Mounting Type User Defined User Defined
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.30.8000 8536.30.8000

Engineering Selection Recommendations

The 2026-35-A1LF is the direct substitute for the obsolete 2026-35-ALF. Both components are manufactured by Bourns Inc. within the TRIGARD® 2026 series and share identical electrical ratings, mechanical packaging, and regulatory compliance certifications. The primary distinction is product status: the 2026-35-A1LF maintains active production status, ensuring availability for new designs and system replacements. Both parts are ROHS3 compliant, REACH unaffected, and classified under ECCN EAR99, meeting equivalent regulatory requirements for deployment in equivalent applications.

Frequently Asked Questions (FAQ)

Q: Can the 2026-35-A1LF be used as a direct replacement for the 2026-35-ALF in existing designs?

A: Yes. Both components share identical electrical specifications (350V DC spark-over, 20kA impulse discharge current), mechanical packaging (Cylinder No Lead, 3 Terminal), and regulatory compliance status. No circuit modifications are required.

Q: What is the primary reason for substitution?

A: The 2026-35-ALF is classified as obsolete. The 2026-35-A1LF is the active equivalent within the same product series, ensuring continued component availability.

Q: Are there any differences in tolerance or performance characteristics?

A: No. Both parts maintain ±20% tolerance on voltage and identical impulse discharge current ratings. Fail-short characteristics are identical (No).

Q: Do both parts meet the same regulatory requirements?

A: Yes. Both are ROHS3 compliant, REACH unaffected, and carry the same ECCN (EAR99) and HTSUS (8536.30.8000) classifications.

Q: Is the package configuration identical?

A: Yes. Both components use Cylinder No Lead, 3 Terminal packaging with user-defined mounting type.

Request Quote (Ships tomorrow)