TE Connectivity Measurement Specialties 2000895 Pressure Transducer Equivalent & Substitute Parts
Part Overview
The TE Connectivity Measurement Specialties 2000895 is a vented gauge pressure transducer designed for industrial automation applications. This component operates within a 0–250 PSI pressure range and delivers analog voltage output between 0.5 V and 4.5 V. The part belongs to the MSP600 series and is classified as obsolete, making identification of functionally equivalent alternatives necessary for system maintenance, repair, and new design implementations where continued supply of the original part cannot be guaranteed.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Operating Pressure | 250 PSI (1723.69 kPa) |
| Output Type | Analog Voltage |
| Output Range | 0.5 V – 4.5 V |
| Supply Voltage | 4.75 V – 5.25 V |
| Accuracy | ±0.25% |
| Pressure Type | Vented Gauge |
| Port Size | Male – 1/4" (6.35 mm) NPT |
| Port Style | Threaded |
| Termination | Cable 2' |
| Maximum Pressure | 500 PSI (3447.38 kPa) |
| Operating Temperature | –40°C – 100°C |
| Package Type | Cylinder |
Substitute Part Grouping Explanation
Substitution of the TE Connectivity 2000895 is determined by strict alignment of the following critical parameters:
Mandatory Matching Parameters:
- Operating pressure rating: 250 PSI
- Output type: Analog voltage
- Output voltage range: 0.5 V – 4.5 V
- Supply voltage range: 4.75 V – 5.25 V
- Pressure type: Vented gauge
- Port configuration: Male 1/4" NPT threaded
- Cable termination: 2' length
- Maximum pressure rating: 500 PSI
- Package form factor: Cylinder
The TE Connectivity M5131-000005-250PG meets all mandatory electrical and mechanical parameters required for direct substitution. Both components share identical pressure ratings, output specifications, supply voltage requirements, port configurations, and physical packaging. The substitute part operates within an extended temperature range and maintains functional compatibility with systems designed for the original 2000895 transducer.
Parameter Comparison
| Parameter | 2000895 (MSP600) | M5131-000005-250PG (M5100) | Compatibility |
|---|---|---|---|
| Operating Pressure | 250 PSI (1723.69 kPa) | 250 PSI (1723.69 kPa) | Identical |
| Output Type | Analog Voltage | Analog Voltage | Identical |
| Output Range | 0.5 V – 4.5 V | 0.5 V – 4.5 V | Identical |
| Supply Voltage | 4.75 V – 5.25 V | 4.75 V – 5.25 V | Identical |
| Accuracy | ±0.25% | ±1% | Substitute has wider tolerance |
| Pressure Type | Vented Gauge | Vented Gauge | Identical |
| Port Size | Male – 1/4" (6.35 mm) NPT | Male – 1/4" (6.35 mm) NPT | Identical |
| Port Style | Threaded | Threaded | Identical |
| Termination | Cable 2' | Cable 2' | Identical |
| Maximum Pressure | 500 PSI (3447.38 kPa) | 500 PSI (3447.38 kPa) | Identical |
| Operating Temperature | –40°C – 100°C | –40°C – 125°C | Substitute has extended upper range |
| Package Type | Cylinder | Cylinder | Identical |
| Product Status | Obsolete | Active | Substitute is currently manufactured |
| RoHS Status | Not specified | RoHS Compliant | Substitute meets RoHS requirements |
Engineering Selection Recommendations
The TE Connectivity M5131-000005-250PG (M5100 series) is a direct functional equivalent to the obsolete 2000895 (MSP600 series) for applications requiring 250 PSI vented gauge pressure measurement with 0.5–4.5 V analog output.
Selection Basis:
The substitute part maintains electrical and mechanical compatibility across all critical parameters. Both transducers operate with identical pressure ratings, output specifications, supply voltage requirements, and port configurations. The M5131-000005-250PG is currently in active production status, ensuring long-term availability and supply chain continuity.
The M5131-000005-250PG exhibits a wider accuracy tolerance (±1% versus ±0.25%) and an extended operating temperature range (–40°C to 125°C versus –40°C to 100°C). These differences represent relaxed specifications that do not restrict substitution in applications originally designed for the 2000895.
The substitute part carries RoHS compliance certification, meeting current environmental and regulatory standards for electronic component manufacturing and distribution.
Frequently Asked Questions (FAQ)
Q: Can the M5131-000005-250PG directly replace the 2000895 in existing installations?
A: Yes. Both transducers share identical operating pressure ratings, output voltage ranges, supply voltage requirements, port sizes, and cable termination specifications. No modifications to mounting hardware, electrical connections, or system calibration are required.
Q: What is the difference in accuracy between these two parts?
A: The 2000895 specifies ±0.25% accuracy, while the M5131-000005-250PG specifies ±1% accuracy. The substitute part has a wider tolerance band. Applications requiring the tighter ±0.25% specification must evaluate whether the ±1% tolerance of the substitute is acceptable for their measurement requirements.
Q: Does the extended temperature range of the M5131-000005-250PG affect compatibility?
A: No. The substitute part operates from –40°C to 125°C, compared to the original part's –40°C to 100°C range. The extended upper temperature limit represents an enhancement that does not compromise compatibility with systems designed for the original temperature specification.
Q: Are there any differences in physical packaging between these parts?
A: Both parts use identical cylinder package form factors with Male 1/4" NPT threaded ports and 2' cable terminations. Physical mounting and connection procedures are identical.
Q: What is the significance of the RoHS compliance status of the substitute part?
A: The M5131-000005-250PG carries RoHS compliance certification, indicating compliance with the Restriction of Hazardous Substances Directive. This certification is relevant for applications subject to environmental regulations or customer requirements mandating RoHS-compliant components.
Q: Is the substitute part currently available?
A: Yes. The M5131-000005-250PG is classified as active product status, indicating current manufacturing and availability through TE Connectivity distribution channels. The original 2000895 is obsolete and no longer manufactured.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts