Part Overview

The TE Connectivity Measurement Specialties 2000895 is a vented gauge pressure transducer designed for industrial automation applications. This component operates within a 0–250 PSI pressure range and delivers analog voltage output between 0.5 V and 4.5 V. The part belongs to the MSP600 series and is classified as obsolete, making identification of functionally equivalent alternatives necessary for system maintenance, repair, and new design implementations where continued supply of the original part cannot be guaranteed.

Substiute Parts

2000895
TE Connectivity Measurement SpecialtiesIn Stock: 7682000895 Datasheet
2000895
Current Part
M5131-000005-250PG
TE Connectivity Measurement SpecialtiesIn Stock: 1007M5131-000005-250PG Datasheet
M5131-000005-250PG
Similar

Key Parameters

Parameter Value
Operating Pressure 250 PSI (1723.69 kPa)
Output Type Analog Voltage
Output Range 0.5 V – 4.5 V
Supply Voltage 4.75 V – 5.25 V
Accuracy ±0.25%
Pressure Type Vented Gauge
Port Size Male – 1/4" (6.35 mm) NPT
Port Style Threaded
Termination Cable 2'
Maximum Pressure 500 PSI (3447.38 kPa)
Operating Temperature –40°C – 100°C
Package Type Cylinder

Substitute Part Grouping Explanation

Substitution of the TE Connectivity 2000895 is determined by strict alignment of the following critical parameters:

Mandatory Matching Parameters:

  • Operating pressure rating: 250 PSI
  • Output type: Analog voltage
  • Output voltage range: 0.5 V – 4.5 V
  • Supply voltage range: 4.75 V – 5.25 V
  • Pressure type: Vented gauge
  • Port configuration: Male 1/4" NPT threaded
  • Cable termination: 2' length
  • Maximum pressure rating: 500 PSI
  • Package form factor: Cylinder

The TE Connectivity M5131-000005-250PG meets all mandatory electrical and mechanical parameters required for direct substitution. Both components share identical pressure ratings, output specifications, supply voltage requirements, port configurations, and physical packaging. The substitute part operates within an extended temperature range and maintains functional compatibility with systems designed for the original 2000895 transducer.

Parameter Comparison

Parameter 2000895 (MSP600) M5131-000005-250PG (M5100) Compatibility
Operating Pressure 250 PSI (1723.69 kPa) 250 PSI (1723.69 kPa) Identical
Output Type Analog Voltage Analog Voltage Identical
Output Range 0.5 V – 4.5 V 0.5 V – 4.5 V Identical
Supply Voltage 4.75 V – 5.25 V 4.75 V – 5.25 V Identical
Accuracy ±0.25% ±1% Substitute has wider tolerance
Pressure Type Vented Gauge Vented Gauge Identical
Port Size Male – 1/4" (6.35 mm) NPT Male – 1/4" (6.35 mm) NPT Identical
Port Style Threaded Threaded Identical
Termination Cable 2' Cable 2' Identical
Maximum Pressure 500 PSI (3447.38 kPa) 500 PSI (3447.38 kPa) Identical
Operating Temperature –40°C – 100°C –40°C – 125°C Substitute has extended upper range
Package Type Cylinder Cylinder Identical
Product Status Obsolete Active Substitute is currently manufactured
RoHS Status Not specified RoHS Compliant Substitute meets RoHS requirements

Engineering Selection Recommendations

The TE Connectivity M5131-000005-250PG (M5100 series) is a direct functional equivalent to the obsolete 2000895 (MSP600 series) for applications requiring 250 PSI vented gauge pressure measurement with 0.5–4.5 V analog output.

Selection Basis:

The substitute part maintains electrical and mechanical compatibility across all critical parameters. Both transducers operate with identical pressure ratings, output specifications, supply voltage requirements, and port configurations. The M5131-000005-250PG is currently in active production status, ensuring long-term availability and supply chain continuity.

The M5131-000005-250PG exhibits a wider accuracy tolerance (±1% versus ±0.25%) and an extended operating temperature range (–40°C to 125°C versus –40°C to 100°C). These differences represent relaxed specifications that do not restrict substitution in applications originally designed for the 2000895.

The substitute part carries RoHS compliance certification, meeting current environmental and regulatory standards for electronic component manufacturing and distribution.

Frequently Asked Questions (FAQ)

Q: Can the M5131-000005-250PG directly replace the 2000895 in existing installations?

A: Yes. Both transducers share identical operating pressure ratings, output voltage ranges, supply voltage requirements, port sizes, and cable termination specifications. No modifications to mounting hardware, electrical connections, or system calibration are required.

Q: What is the difference in accuracy between these two parts?

A: The 2000895 specifies ±0.25% accuracy, while the M5131-000005-250PG specifies ±1% accuracy. The substitute part has a wider tolerance band. Applications requiring the tighter ±0.25% specification must evaluate whether the ±1% tolerance of the substitute is acceptable for their measurement requirements.

Q: Does the extended temperature range of the M5131-000005-250PG affect compatibility?

A: No. The substitute part operates from –40°C to 125°C, compared to the original part's –40°C to 100°C range. The extended upper temperature limit represents an enhancement that does not compromise compatibility with systems designed for the original temperature specification.

Q: Are there any differences in physical packaging between these parts?

A: Both parts use identical cylinder package form factors with Male 1/4" NPT threaded ports and 2' cable terminations. Physical mounting and connection procedures are identical.

Q: What is the significance of the RoHS compliance status of the substitute part?

A: The M5131-000005-250PG carries RoHS compliance certification, indicating compliance with the Restriction of Hazardous Substances Directive. This certification is relevant for applications subject to environmental regulations or customer requirements mandating RoHS-compliant components.

Q: Is the substitute part currently available?

A: Yes. The M5131-000005-250PG is classified as active product status, indicating current manufacturing and availability through TE Connectivity distribution channels. The original 2000895 is obsolete and no longer manufactured.