Equivalent & Substitute Parts for 1EEA2

Part Overview

The 1EEA2 is a Power Entry Connector Receptacle manufactured by TE Connectivity Corcom Filters, designed for IEC 320-C14 panel mount applications. This component features male blades, filtered EMI/RFI protection for commercial use, and quick connect termination. The 1EEA2 is classified as obsolete, necessitating identification of active equivalent and substitute parts to maintain design continuity and ensure ongoing component availability for new production and field service applications.

Substiute Parts

1EEA2
TE Connectivity Corcom FiltersIn Stock: 9791EEA2 Datasheet
1EEA2
Current Part
1EEJ2
TE Connectivity Corcom FiltersIn Stock: 13261EEJ2 Datasheet
1EEJ2
MFR Recommended
FN9226-1-06
Schaffner EMC Inc.In Stock: 2025FN9226-1-06 Datasheet
FN9226-1-06
Similar

Key Parameters

Parameter Value
Connector Style IEC 320-C14
Connector Type Receptacle, Male Blades
Current Rating - Appliance Inlet 1A
Voltage Rating - Appliance Inlet 120/250VAC
Number of Positions 3
Filter Type Filtered (EMI, RFI) - Commercial
Current Rating - Filter 1A
Mounting Type Panel Mount, Flange, Right Angle
Termination Quick Connect - 0.250" (6.3mm)
Panel Cutout Dimensions Rectangular - 30.48mm x 22.86mm
Approval Agency CSA, UL, VDE
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the obsolete 1EEA2 is determined by strict equivalence across the following critical parameters:

Mandatory Matching Parameters:

  • Connector Style: IEC 320-C14
  • Connector Type: Receptacle, Male Blades
  • Number of Positions: 3
  • Filter Type: Filtered (EMI, RFI) - Commercial
  • Current Rating - Filter: 1A
  • Mounting Type: Panel Mount, Flange, Right Angle
  • Termination: Quick Connect - 0.250" (6.3mm)
  • Voltage Rating - Appliance Inlet: 120/250VAC
  • Current Rating - Appliance Inlet: 1A

Substitute Parts Identified:

  1. 1EEJ2 (TE Connectivity Corcom Filters) - MFR Recommended substitute. Active product status. Maintains all mandatory electrical and mechanical parameters. Differs in mounting configuration (Through Hole addition) and REACH compliance status.

  2. FN9226-1-06 (Schaffner EMC Inc.) - Similar substitute. Active product status. Maintains core connector specifications and filter ratings. Panel cutout dimensions differ (34.40mm x 22.60mm versus 30.48mm x 22.86mm). Appliance inlet current and voltage ratings not specified in documentation.

Parameter Comparison

Parameter 1EEA2 1EEJ2 FN9226-1-06
Manufacturer TE Connectivity Corcom Filters TE Connectivity Corcom Filters Schaffner EMC Inc.
Product Status Obsolete Active Active
Connector Style IEC 320-C14 IEC 320-C14 IEC 320-C14
Connector Type Receptacle, Male Blades Receptacle, Male Blades Receptacle, Male Blades
Current Rating - Appliance Inlet 1A 1A Not Specified
Voltage Rating - Appliance Inlet 120/250VAC 120/250VAC Not Specified
Number of Positions 3 3 3
Filter Type Filtered (EMI, RFI) - Commercial Filtered (EMI, RFI) - Commercial Filtered (EMI, RFI) - Commercial
Current Rating - Filter 1A 1A 1A
Mounting Type Panel Mount, Flange, Right Angle Panel Mount, Flange, Through Hole, Right Angle Panel Mount, Flange, Right Angle
Termination Quick Connect - 0.250" (6.3mm) Quick Connect - 0.250" (6.3mm) Quick Connect - 0.250" (6.3mm)
Panel Cutout Dimensions Rectangular - 30.48mm x 22.86mm Rectangular - 30.48mm x 22.86mm Rectangular - 34.40mm x 22.60mm
Approval Agency CSA, UL, VDE CSA, UL, VDE CSA, ENEC, SEMKO, UL
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) Not Applicable
REACH Status Vendor Undefined REACH Affected REACH Unaffected

Engineering Selection Recommendations

1EEJ2 (Primary Substitute): The 1EEJ2 is the manufacturer-recommended substitute for the obsolete 1EEA2. Both components are manufactured by TE Connectivity Corcom Filters and maintain identical electrical ratings (1A at 120/250VAC), connector configuration (IEC 320-C14 Receptacle, Male Blades), and filter specifications. The 1EEJ2 is active in production with higher inventory availability (1243 units). The addition of through-hole mounting capability in the 1EEJ2 provides enhanced mechanical retention without compromising the primary right-angle panel mount configuration. Both components carry equivalent regulatory approvals (CSA, UL, VDE) and ROHS3 compliance. The 1EEJ2 is suitable for direct replacement in applications where the original 1EEA2 was specified.

FN9226-1-06 (Alternative Substitute): The FN9226-1-06 manufactured by Schaffner EMC Inc. provides functional equivalence for IEC 320-C14 filtered power entry applications. This component maintains the 1A filter current rating, 3-position configuration, and quick connect termination. The FN9226-1-06 carries broader regulatory approvals (CSA, ENEC, SEMKO, UL) and is REACH Unaffected, which may be advantageous for certain supply chain requirements. However, the panel cutout dimensions differ (34.40mm x 22.60mm versus 30.48mm x 22.86mm), requiring panel modification or redesign. Appliance inlet current and voltage ratings are not specified in available documentation. The FN9226-1-06 is suitable for new designs or applications where panel cutout modification is feasible.

Frequently Asked Questions (FAQ)

Q: Can the 1EEJ2 be used as a direct replacement for the 1EEA2 without design modifications?

A: Yes. The 1EEJ2 maintains identical electrical specifications (1A at 120/250VAC), connector style (IEC 320-C14), filter type (Filtered EMI/RFI Commercial), and panel cutout dimensions (30.48mm x 22.86mm). The addition of through-hole mounting in the 1EEJ2 does not prevent its use in applications originally designed for the 1EEA2.

Q: What is the primary difference between the 1EEJ2 and FN9226-1-06?

A: The 1EEJ2 and FN9226-1-06 differ in panel cutout dimensions and manufacturer. The 1EEJ2 maintains the original 30.48mm x 22.86mm cutout, while the FN9226-1-06 requires a 34.40mm x 22.60mm cutout. Additionally, the FN9226-1-06 does not specify appliance inlet current and voltage ratings in available documentation.

Q: Is the FN9226-1-06 suitable for applications requiring 1A at 120/250VAC?

A: The FN9226-1-06 maintains a 1A filter current rating and is designed for IEC 320-C14 applications. However, appliance inlet current and voltage ratings are not specified in the provided documentation. Confirmation of these parameters with the manufacturer is necessary for applications with strict electrical requirements.

Q: What packaging options are available for these substitutes?

A: The 1EEJ2 is supplied in Bulk packaging. The FN9226-1-06 is supplied in Tray packaging. The original 1EEA2 packaging type is not specified in available documentation.

Q: Are all three components ROHS3 compliant?

A: Yes. The 1EEA2, 1EEJ2, and FN9226-1-06 are all ROHS3 Compliant.

Q: What regulatory approvals apply to each component?

A: The 1EEA2 and 1EEJ2 carry CSA, UL, and VDE approvals. The FN9226-1-06 carries CSA, ENEC, SEMKO, and UL approvals. All three components meet the regulatory requirements for AC power connector applications in their respective markets.

Q: Does the FN9226-1-06 have moisture sensitivity considerations?

A: The FN9226-1-06 has a Moisture Sensitivity Level classification of Not Applicable, indicating no moisture sensitivity restrictions. The 1EEA2 and 1EEJ2 both have MSL 1 (Unlimited), indicating no moisture sensitivity restrictions.

Request Quote (Ships tomorrow)