Altech Corporation 1C5UM Thermal Magnetic Circuit Breaker Equivalent & Substitute Parts

Part Overview

The Altech Corporation 1C5UM is a single-pole thermal magnetic circuit breaker rated for 5A at 480 V AC and 42 V DC, designed for DIN rail mounting with lever actuation. This component is active in production and widely used in industrial control and distribution applications. Substitute parts become necessary when the primary model is unavailable, when inventory constraints require alternative sourcing, or when application requirements permit operation within the defined electrical and mechanical parameter ranges of the V-EA series.

Substiute Parts

1C5UM
Altech CorporationIn Stock: 9591C5UM Datasheet
1C5UM
Current Part
1D5UM
Altech CorporationIn Stock: 10151D5UM Datasheet
1D5UM
Parametric Equivalent
1E5UM
Altech CorporationIn Stock: 9611E5UM Datasheet
1E5UM
Parametric Equivalent
1G5UM
Altech CorporationIn Stock: 11931G5UM Datasheet
1G5UM
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 1C5UM
Manufacturer Altech Corporation
Series V-EA
Breaker Type Thermal Magnetic
Current Rating 5A
Voltage Rating - AC 480 V
Voltage Rating - DC 42 V
Mounting Type DIN Rail
Number of Poles 1
Actuator Type Lever
Approval Agencies CSA, UL508, VDE
RoHS Status ROHS3 Compliant
Product Status Active

Substitute Part Grouping Explanation

Substitution within the Altech V-EA series is determined by the following critical parameters:

  • Current Rating: 5A (all substitutes maintain this specification)
  • Breaker Type: Thermal Magnetic (all substitutes maintain this specification)
  • Mounting Type: DIN Rail (all substitutes maintain this specification)
  • Number of Poles: 1 (all substitutes maintain this specification)
  • Actuator Type: Lever (all substitutes maintain this specification)
  • DC Voltage Rating: 42 V (all substitutes maintain this specification)

The primary differentiator among substitute parts is the AC voltage rating. The 1C5UM and 1D5UM are rated for 480 V AC, while the 1E5UM and 1G5UM are rated for 277 V AC. These voltage classes define distinct application domains and determine substitution eligibility based on the end-use circuit voltage.

Parameter Comparison

Parameter 1C5UM 1D5UM 1E5UM 1G5UM
Manufacturer Altech Corporation Altech Corporation Altech Corporation Altech Corporation
Series V-EA V-EA V-EA V-EA
Breaker Type Thermal Magnetic Thermal Magnetic Thermal Magnetic Thermal Magnetic
Current Rating (Amps) 5A 5A 5A 5A
Voltage Rating - AC 480 V 480 V 277 V 277 V
Voltage Rating - DC 42 V 42 V 42 V 42 V
Mounting Type DIN Rail DIN Rail DIN Rail DIN Rail
Number of Poles 1 1 1 1
Actuator Type Lever Lever Lever Lever
Approval Agency CSA, UL508, VDE CSA, UL508, VDE CSA, UL508 CSA, UL508
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Product Status Active Active Active Active

Engineering Selection Recommendations

All four parts in this substitution group maintain active production status and comply with ROHS3 requirements. The 1C5UM and 1D5UM carry full certification from CSA, UL508, and VDE. The 1E5UM and 1G5UM carry CSA and UL508 certification. Selection between parts must be based on the circuit voltage requirement: 480 V AC applications require either 1C5UM or 1D5UM, while 277 V AC applications require either 1E5UM or 1G5UM. Within each voltage class, parts are mechanically and electrically interchangeable. The distinction between 1C5UM and 1D5UM relates to trip characteristic curves (C-curve versus D-curve), as does the distinction between 1E5UM and 1G5UM (3-curve versus G-curve). Application-specific inrush current and load characteristics determine which curve is appropriate.

Frequently Asked Questions (FAQ)

Q: Can I substitute a 277 V AC rated breaker for a 480 V AC application?

A: No. The voltage rating is a critical parameter that must match the circuit voltage. Using an undersized voltage rating creates a safety hazard and violates electrical code requirements.

Q: Are 1C5UM and 1D5UM fully interchangeable?

A: Both parts share identical electrical ratings (5A, 480 V AC, 42 V DC), mounting type (DIN Rail), pole count (1), and actuator type (Lever). They differ in trip characteristic curve. Substitution is valid only if the application permits the different curve characteristic.

Q: What is the difference between C-curve and D-curve breakers?

A: Trip characteristic curves define the thermal and magnetic trip thresholds. This information is provided in the part descriptions (1C5UM = C-curve, 1D5UM = D-curve) and must be selected based on the specific load and inrush current profile of the protected circuit.

Q: Do all parts carry the same certifications?

A: No. The 1C5UM and 1D5UM carry CSA, UL508, and VDE certifications. The 1E5UM and 1G5UM carry CSA and UL508 certifications. Verify that the required certifications for your application are present on the selected part.

Q: What packaging is available for these parts?

A: All parts are supplied in Bulk packaging.

Q: Are these parts RoHS compliant?

A: Yes. All four parts are ROHS3 Compliant.

Request Quote (Ships tomorrow)