Request Quote
(Ships tomorrow)
Altech Corporation 1C5UM Thermal Magnetic Circuit Breaker Equivalent & Substitute Parts
Part Overview
The Altech Corporation 1C5UM is a single-pole thermal magnetic circuit breaker rated for 5A at 480 V AC and 42 V DC, designed for DIN rail mounting with lever actuation. This component is active in production and widely used in industrial control and distribution applications. Substitute parts become necessary when the primary model is unavailable, when inventory constraints require alternative sourcing, or when application requirements permit operation within the defined electrical and mechanical parameter ranges of the V-EA series.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1C5UM |
| Manufacturer | Altech Corporation |
| Series | V-EA |
| Breaker Type | Thermal Magnetic |
| Current Rating | 5A |
| Voltage Rating - AC | 480 V |
| Voltage Rating - DC | 42 V |
| Mounting Type | DIN Rail |
| Number of Poles | 1 |
| Actuator Type | Lever |
| Approval Agencies | CSA, UL508, VDE |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution within the Altech V-EA series is determined by the following critical parameters:
- Current Rating: 5A (all substitutes maintain this specification)
- Breaker Type: Thermal Magnetic (all substitutes maintain this specification)
- Mounting Type: DIN Rail (all substitutes maintain this specification)
- Number of Poles: 1 (all substitutes maintain this specification)
- Actuator Type: Lever (all substitutes maintain this specification)
- DC Voltage Rating: 42 V (all substitutes maintain this specification)
The primary differentiator among substitute parts is the AC voltage rating. The 1C5UM and 1D5UM are rated for 480 V AC, while the 1E5UM and 1G5UM are rated for 277 V AC. These voltage classes define distinct application domains and determine substitution eligibility based on the end-use circuit voltage.
Parameter Comparison
| Parameter | 1C5UM | 1D5UM | 1E5UM | 1G5UM |
|---|---|---|---|---|
| Manufacturer | Altech Corporation | Altech Corporation | Altech Corporation | Altech Corporation |
| Series | V-EA | V-EA | V-EA | V-EA |
| Breaker Type | Thermal Magnetic | Thermal Magnetic | Thermal Magnetic | Thermal Magnetic |
| Current Rating (Amps) | 5A | 5A | 5A | 5A |
| Voltage Rating - AC | 480 V | 480 V | 277 V | 277 V |
| Voltage Rating - DC | 42 V | 42 V | 42 V | 42 V |
| Mounting Type | DIN Rail | DIN Rail | DIN Rail | DIN Rail |
| Number of Poles | 1 | 1 | 1 | 1 |
| Actuator Type | Lever | Lever | Lever | Lever |
| Approval Agency | CSA, UL508, VDE | CSA, UL508, VDE | CSA, UL508 | CSA, UL508 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Product Status | Active | Active | Active | Active |
Engineering Selection Recommendations
All four parts in this substitution group maintain active production status and comply with ROHS3 requirements. The 1C5UM and 1D5UM carry full certification from CSA, UL508, and VDE. The 1E5UM and 1G5UM carry CSA and UL508 certification. Selection between parts must be based on the circuit voltage requirement: 480 V AC applications require either 1C5UM or 1D5UM, while 277 V AC applications require either 1E5UM or 1G5UM. Within each voltage class, parts are mechanically and electrically interchangeable. The distinction between 1C5UM and 1D5UM relates to trip characteristic curves (C-curve versus D-curve), as does the distinction between 1E5UM and 1G5UM (3-curve versus G-curve). Application-specific inrush current and load characteristics determine which curve is appropriate.
Frequently Asked Questions (FAQ)
Q: Can I substitute a 277 V AC rated breaker for a 480 V AC application?
A: No. The voltage rating is a critical parameter that must match the circuit voltage. Using an undersized voltage rating creates a safety hazard and violates electrical code requirements.
Q: Are 1C5UM and 1D5UM fully interchangeable?
A: Both parts share identical electrical ratings (5A, 480 V AC, 42 V DC), mounting type (DIN Rail), pole count (1), and actuator type (Lever). They differ in trip characteristic curve. Substitution is valid only if the application permits the different curve characteristic.
Q: What is the difference between C-curve and D-curve breakers?
A: Trip characteristic curves define the thermal and magnetic trip thresholds. This information is provided in the part descriptions (1C5UM = C-curve, 1D5UM = D-curve) and must be selected based on the specific load and inrush current profile of the protected circuit.
Q: Do all parts carry the same certifications?
A: No. The 1C5UM and 1D5UM carry CSA, UL508, and VDE certifications. The 1E5UM and 1G5UM carry CSA and UL508 certifications. Verify that the required certifications for your application are present on the selected part.
Q: What packaging is available for these parts?
A: All parts are supplied in Bulk packaging.
Q: Are these parts RoHS compliant?
A: Yes. All four parts are ROHS3 Compliant.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts