Phoenix Contact 1897733 Terminal Block - Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 1897733 is a 6-position wire-to-board terminal block with 0.200" (5.08mm) pitch, designed for horizontal board mounting using press-fit technology. This component is classified as obsolete, making identification of suitable substitutes essential for ongoing system maintenance and new design implementations. The COMBICON EMKDS series terminal block provides screw-based wire termination with rising cage clamp technology, supporting wire gauges from 14-30 AWG at 10 A and 300 V operating conditions.

Substiute Parts

1897733
Phoenix ContactIn Stock: 9161897733 Datasheet
1897733
Current Part
1710726
Phoenix ContactIn Stock: 10291710726 Datasheet
1710726
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 1897733
Manufacturer Phoenix Contact
Category Terminal Blocks
Series COMBICON EMKDS
Positions Per Level 6
Pitch 0.200" (5.08mm)
Mating Orientation Horizontal with Board
Current Rating 10 A
Voltage Rating 300 V
Wire Gauge 14-30 AWG
Mounting Type Press Fit
Wire Termination Screw - Rising Cage Clamp
Screw Thread M2
Torque Specification 0.22-0.25 Nm (1.9-2.2 Lb-In)
Housing Material Polyamide (PA), Nylon
Color Green
Product Status Obsolete
RoHS Status RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the Phoenix Contact 1897733 is determined by the following critical parameters:

Mandatory Compatibility Parameters:

  • Positions per level: 6
  • Pitch: 0.200" (5.08mm)
  • Mating orientation: Horizontal with Board
  • Wire gauge support: 14-30 AWG
  • Wire termination method: Screw - Rising Cage Clamp
  • Housing material: Polyamide (PA), Nylon
  • Color: Green

Allowable Variation Parameters:

  • Mounting type: Press Fit (main part) to Through Hole (substitute)
  • Current rating: 10 A (main part) to 15 A (substitute) — higher rating is acceptable
  • Voltage rating: 300 V (both parts match)
  • Screw thread: M2 (main part) to M3 (substitute) — requires PCB redesign
  • Torque specification: 0.22-0.25 Nm (main part) to 0.5-0.6 Nm (substitute) — reflects M3 thread change
  • Series: COMBICON EMKDS (main part) to COMBICON MKDS (substitute)
  • Product status: Obsolete (main part) to Active (substitute)

The Phoenix Contact 1710726 qualifies as a substitute because it maintains all mandatory compatibility parameters while offering improved current capacity and active product status. The transition from press-fit to through-hole mounting and M2 to M3 screw thread represents a design-level change requiring PCB modification.

Parameter Comparison

Parameter 1897733 (Main Part) 1710726 (Substitute)
Manufacturer Phoenix Contact Phoenix Contact
Category Terminal Blocks Terminal Blocks
Series COMBICON EMKDS COMBICON MKDS
Positions Per Level 6 6
Pitch 0.200" (5.08mm) 0.200" (5.08mm)
Mating Orientation Horizontal with Board Horizontal with Board
Current Rating 10 A 15 A
Voltage Rating 300 V 300 V
Wire Gauge 14-30 AWG 14-30 AWG
Mounting Type Press Fit Through Hole
Wire Termination Screw - Rising Cage Clamp Screw - Rising Cage Clamp
Screw Thread M2 M3
Torque Specification 0.22-0.25 Nm (1.9-2.2 Lb-In) 0.5-0.6 Nm (4.4-5.3 Lb-In)
Housing Material Polyamide (PA), Nylon Polyamide (PA), Nylon
Color Green Green
Product Status Obsolete Active
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

For Direct Replacement (Minimal Redesign): The Phoenix Contact 1710726 is the qualified substitute for the 1897733. Both components maintain identical electrical specifications (300 V, wire gauge 14-30 AWG, screw-based rising cage clamp termination) and mechanical footprint (6 positions, 5.08mm pitch, horizontal board orientation). The 1710726 offers enhanced current capacity (15 A versus 10 A), which provides design margin for existing applications.

Design Considerations: The transition from press-fit (1897733) to through-hole (1710726) mounting requires PCB modification. The screw thread change from M2 to M3 necessitates updated torque specifications during assembly (0.5-0.6 Nm for the 1710726 versus 0.22-0.25 Nm for the 1897733).

Compliance Status: The 1710726 holds active product status with ROHS3 compliance, compared to the obsolete 1897733 with RoHS compliance. Both components maintain MSL 1 (Unlimited) moisture sensitivity rating. The 1710726 includes REACH Unaffected designation, confirming regulatory alignment for new designs.

Frequently Asked Questions (FAQ)

Q: Can the 1710726 be used as a direct drop-in replacement for the 1897733?

A: No. While both components share identical electrical ratings and wire termination methods, the mounting type differs (through-hole versus press-fit). PCB redesign is required to accommodate the 1710726's through-hole mounting pads and M3 screw holes.

Q: What are the key differences between these two terminal blocks?

A: The primary differences are mounting technology (press-fit to through-hole), screw thread size (M2 to M3), current capacity (10 A to 15 A), and product status (obsolete to active). Electrical specifications, pitch, position count, and wire gauge support remain identical.

Q: Is the higher current rating of the 1710726 compatible with existing designs?

A: Yes. The 1710726's 15 A rating exceeds the 1897733's 10 A specification, making it suitable for applications designed around the lower rating. No electrical redesign is necessary from a current capacity perspective.

Q: What torque values should be used during assembly?

A: The 1897733 requires 0.22-0.25 Nm (1.9-2.2 Lb-In) for M2 screws. The 1710726 requires 0.5-0.6 Nm (4.4-5.3 Lb-In) for M3 screws. Assembly procedures must be updated accordingly.

Q: Are both components RoHS compliant?

A: Yes. The 1897733 is RoHS Compliant. The 1710726 is ROHS3 Compliant, representing a more current regulatory standard. Both meet environmental compliance requirements.

Q: What is the pitch spacing, and does it remain the same?

A: Both components maintain 0.200" (5.08mm) pitch spacing. PCB layout modifications are required only for mounting hole repositioning (press-fit to through-hole conversion), not for wire connection spacing.

Request Quote (Ships tomorrow)