Request Quote
(Ships tomorrow)
Hammond Manufacturing 182G18 Toroidal Power Transformer - Equivalent & Substitute Parts
Part Overview
The Hammond Manufacturing 182G18 is a 225VA toroidal power transformer designed for chassis mount applications. This transformer features dual primary and secondary windings, supporting input voltages of 117V or 234V with output configurations of 18V parallel or 36V series. The part is classified as obsolete, making identification of suitable substitute components essential for ongoing system maintenance and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 182G18 |
| Manufacturer | Hammond Manufacturing |
| Product Type | Toroidal Power Transformer |
| Power Rating | 225VA |
| Primary Voltage Options | 117V, 234V |
| Secondary Voltage (Parallel) | 18V |
| Secondary Voltage (Series) | 36V |
| Maximum Output Current (Parallel) | 12.5A |
| Maximum Output Current (Series) | 6.25A |
| Primary Windings | Dual |
| Secondary Windings | Dual |
| Mounting Type | Chassis Mount |
| Termination Style | Wire Leads |
| Isolation Voltage | 4000Vrms |
| Product Status | Obsolete |
| RoHS Compliance | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the 182G18 is determined by strict equivalence across the following critical parameters:
- Power rating: 225VA
- Primary voltage configuration: Dual windings supporting 117V and 234V
- Secondary voltage configuration: Dual windings supporting 18V parallel and 36V series
- Output current capacity: 12.5A parallel, 6.25A series
- Isolation voltage: 4000Vrms
- Mounting configuration: Chassis mount with wire lead termination
- Transformer type: Toroidal construction
The substitute part 1182G18 meets all these criteria, providing functional and electrical equivalence while offering improved product status and availability.
Parameter Comparison
| Parameter | 182G18 (Main Part) | 1182G18 (Substitute) |
|---|---|---|
| Manufacturer | Hammond Manufacturing | Hammond Manufacturing |
| Product Type | Toroidal Power Transformer | Toroidal Power Transformer |
| Power Rating | 225VA | 225VA |
| Primary Voltage Options | 117V, 234V | 117V, 234V |
| Secondary Voltage (Parallel) | 18V | 18V |
| Secondary Voltage (Series) | 36V | 36V |
| Maximum Output Current (Parallel) | 12.5A | 12.5A |
| Maximum Output Current (Series) | 6.25A | 6.25A |
| Primary Windings | Dual | Dual |
| Secondary Windings | Dual | Dual |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Wire Leads | Wire Leads |
| Isolation Voltage | 4000Vrms | 4000Vrms |
| Product Status | Obsolete | Active |
| RoHS Compliance | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
The 1182G18 serves as the direct substitute for the obsolete 182G18. Both components maintain identical electrical specifications across all critical parameters: 225VA power rating, dual primary and secondary winding configurations, 117V/234V primary voltage support, 18V/36V secondary voltage capability, and 4000Vrms isolation voltage.
The 1182G18 offers the advantage of active product status, ensuring continued availability and supply chain reliability. Both parts maintain ROHS3 compliance and REACH unaffected status, satisfying current regulatory requirements for electronic component procurement.
Frequently Asked Questions (FAQ)
Q: Can the 1182G18 directly replace the 182G18 in existing applications?
A: Yes. The 1182G18 provides complete electrical and functional equivalence. All voltage ratings, current capacities, winding configurations, isolation specifications, and mounting characteristics are identical.
Q: What are the key differences between these two parts?
A: The primary differences are product status and packaging. The 182G18 is obsolete, while the 1182G18 is active. The 1182G18 is supplied in box packaging, whereas the 182G18 uses standard packaging. Electrically and mechanically, both parts are equivalent.
Q: Are there any physical dimension variations that would affect installation?
A: Both transformers are chassis mount toroidal units with wire lead termination. The 1182G18 has a diameter of 114.30mm and height of 47.75mm. The 182G18 height is specified as 48.26mm maximum. These minor dimensional differences do not affect compatibility in standard chassis mount applications.
Q: Do both parts meet current compliance standards?
A: Yes. Both the 182G18 and 1182G18 are ROHS3 compliant and REACH unaffected, meeting current regulatory requirements for electronic component use.
Q: Which part should be selected for new designs?
A: The 1182G18 should be selected for new designs due to its active product status and assured long-term availability.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts