Phoenix Contact 1826306 Terminal Block Plug - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 1826306 is a 4-position terminal block plug with female sockets, 0.200" (5.08mm) pitch, and 225° free-hanging wire entry orientation. This component is classified as an active product and is used in industrial control and power distribution applications requiring screw-type termination with rising cage clamp technology. Substitute parts are identified when equivalent electrical ratings, mechanical compatibility, and termination methods align with the original specification, enabling direct replacement in applications where wire entry angle and housing material variations are acceptable.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1826306 |
| Manufacturer | Phoenix Contact |
| Category | Terminal Blocks |
| Type | Plug, Female Sockets |
| Number of Positions | 4 |
| Pitch | 0.200" (5.08mm) |
| Plug Wire Entry | 225° |
| Termination Style | Screw - Rising Cage Clamp |
| Current - UL | 15 A |
| Voltage - UL | 300 V |
| Wire Gauge Range - AWG | 12-30 AWG |
| Wire Gauge Range - mm² | 0.2-2.5mm² |
| Screw Size | M3 |
| Material Flammability Rating | UL94 V-0 |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution of the Phoenix Contact 1826306 is based on the following critical parameters that must align between the main part and substitute:
- Electrical Compatibility: Current rating (UL: 15 A minimum), voltage rating (UL: 300 V minimum), and wire gauge acceptance (12-30 AWG or 0.2-2.5mm² minimum range)
- Mechanical Compatibility: 4-position configuration, 0.200" (5.08mm) pitch, female socket type, and screw-type rising cage clamp termination
- Physical Form Factor: Free-hanging (in-line) mounting type, M3 screw size, and insulation height of 0.610" (15.49mm)
- Regulatory Compliance: UL94 V-0 flammability rating and ROHS3 compliance
The substitute part TE Connectivity AMP Connectors 796634-4 meets these core substitution criteria. The primary difference is the wire entry angle (180° versus 225°), which represents a mechanical orientation variation acceptable in applications where the connector orientation can be adjusted to accommodate the straight wire entry configuration.
Parameter Comparison
| Parameter | Phoenix Contact 1826306 | TE Connectivity 796634-4 | Compatibility Notes |
|---|---|---|---|
| Number of Positions | 4 | 4 | Identical |
| Pitch | 0.200" (5.08mm) | 0.200" (5.08mm) | Identical |
| Type | Plug, Female Sockets | Plug, Female Sockets | Identical |
| Termination Style | Screw - Rising Cage Clamp | Screw - Rising Cage Clamp | Identical |
| Plug Wire Entry | 225° | 180° | Different orientation; mechanical adjustment may be required |
| Current - UL | 15 A | 15 A | Identical |
| Voltage - UL | 300 V | 300 V | Identical |
| Wire Gauge Range - AWG | 12-30 AWG | 12-30 AWG | Identical |
| Wire Gauge Range - mm² | 0.2-2.5mm² | 0.05-3mm² | Substitute accepts wider range |
| Screw Size | M3 | M3 | Identical |
| Insulation Height | 0.610" (15.49mm) | 0.610" (15.49mm) | Identical |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 | Identical |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Identical |
| Mounting Type | Free Hanging (In-Line) | Free Hanging (In-Line) | Identical |
| Color | Green | Green | Identical |
| Contact Mating Finish | Tin | Tin | Identical |
| Features | Retention Latches (Non-Wire Side) | Retention Latches (Non-Wire Side) | Identical |
Engineering Selection Recommendations
The TE Connectivity AMP Connectors 796634-4 is a qualified substitute for the Phoenix Contact 1826306 based on the following engineering criteria:
Electrical Equivalence: Both components maintain identical UL current (15 A) and voltage (300 V) ratings, ensuring no degradation in electrical performance. The substitute's expanded wire gauge acceptance (0.05-3mm²) provides additional flexibility without compromising the original 0.2-2.5mm² specification range.
Mechanical Equivalence: Both components feature identical 4-position, 0.200" (5.08mm) pitch configurations with screw-type rising cage clamp termination and M3 screw sizing. The insulation height and mounting type are identical, supporting direct mechanical integration.
Regulatory Compliance: Both components carry ROHS3 compliance and UL94 V-0 flammability ratings, meeting identical regulatory requirements for industrial applications.
Primary Consideration: The wire entry angle differs (225° versus 180°). This represents a mechanical orientation variation that requires assessment of the specific application layout. In applications where connector orientation can be adjusted or where straight wire entry is acceptable, this substitute provides full functional equivalence.
Product Status: Both components are active products with confirmed inventory availability, supporting supply chain continuity.
Frequently Asked Questions (FAQ)
Q: Can the TE Connectivity 796634-4 directly replace the Phoenix Contact 1826306 without any modifications?
A: Electrical and mechanical compatibility is confirmed. The primary consideration is the wire entry angle: the Phoenix Contact uses 225° entry while the TE Connectivity uses 180° entry. If your application layout accommodates straight wire entry or allows connector repositioning, direct replacement is feasible. If the 225° angle is a critical design requirement, physical layout verification is necessary.
Q: Are the electrical ratings identical between these two parts?
A: Yes. Both components are rated for 15 A (UL) and 300 V (UL). Wire gauge acceptance ranges are compatible, with the TE Connectivity part accepting a slightly wider range (0.05-3mm² versus 0.2-2.5mm²).
Q: Do both parts meet the same regulatory standards?
A: Yes. Both components are ROHS3 compliant and carry UL94 V-0 flammability ratings, meeting identical regulatory requirements for industrial control and power distribution applications.
Q: What is the significance of the different wire entry angles?
A: The 225° angle on the Phoenix Contact provides angled wire entry, while the 180° angle on the TE Connectivity provides straight wire entry. This is a mechanical orientation difference that affects how wires are routed into the connector. Application layout and wire routing requirements determine whether this difference impacts usability.
Q: Are the screw termination specifications the same?
A: Both components use M3 screws with rising cage clamp termination. The Phoenix Contact specifies 0.5-0.6 Nm torque while the TE Connectivity specifies 0.79 Nm. Both values are within acceptable ranges for M3 screw termination in terminal block applications.
Q: Can I use the TE Connectivity part for wire gauges smaller than 0.2mm²?
A: The TE Connectivity part accepts wire gauges down to 0.05mm², which exceeds the original Phoenix Contact specification of 0.2mm² minimum. However, if your application requires the original 0.2mm² minimum specification, verify that smaller gauges are not used in your circuit design.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts