Phoenix Contact 1822574 Terminal Block - Equivalent & Substitute Parts

Part Overview

The Phoenix Contact 1822574 is a 6-position wire-to-board terminal block designed for vertical PCB mounting with 5.00mm pitch spacing. This component facilitates electrical connections between external wiring and printed circuit boards in industrial control and automation applications. The part is currently active in production with full inventory availability. Substitute parts are identified to provide alternative sourcing options when the primary part is unavailable or when design flexibility permits component interchange based on equivalent electrical and mechanical specifications.

Substiute Parts

1822574
Phoenix ContactIn Stock: 10511822574 Datasheet
1822574
Current Part
2086-3106
WAGO CorporationIn Stock: 11522086-3106 Datasheet
2086-3106
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number 1822574
Manufacturer Phoenix Contact
Category Terminal Blocks
Series COMBICON SPT-THR
Positions Per Level 6
Pitch 0.197" (5.00mm)
Mating Orientation Vertical with Board
Current Rating 10 A
Voltage Rating 300 V
Wire Gauge 16-24 AWG
Mounting Type Through Hole
Wire Termination Screwless - Leg Spring, Push-In Spring
Housing Material Liquid Crystal Polymer (LCP)
Contact Plating Tin Plated
RoHS Status ROHS3 Compliant
Product Status Active

Substitute Part Grouping Explanation

Substitute parts for the Phoenix Contact 1822574 are qualified based on the following critical parameters that determine functional and mechanical compatibility:

Electrical Equivalence Criteria:

  • Positions Per Level: 6
  • Pitch: 0.197" (5.00mm)
  • Current Rating: 10 A minimum
  • Voltage Rating: 300 V minimum
  • Wire Gauge Compatibility: 16-24 AWG

Mechanical Equivalence Criteria:

  • Mating Orientation: Vertical with Board
  • Mounting Type: Through Hole
  • PCB footprint compatibility based on pitch and position count

Regulatory Equivalence Criteria:

  • RoHS3 Compliance
  • REACH Unaffected status

The WAGO Corporation 2086-3106 meets all critical electrical, mechanical, and regulatory parameters. While housing material and wire termination method differ (PPA with push-button clamp versus LCP with leg spring), these variations do not affect functional substitution when electrical and mechanical requirements are satisfied.

Parameter Comparison

Parameter Phoenix Contact 1822574 WAGO 2086-3106
Manufacturer Part Number 1822574 2086-3106
Manufacturer Phoenix Contact WAGO Corporation
Positions Per Level 6 6
Pitch 0.197" (5.00mm) 0.197" (5.00mm)
Mating Orientation Vertical with Board Vertical with Board
Current Rating 10 A 10 A
Voltage Rating 300 V 300 V
Wire Gauge 16-24 AWG 16-24 AWG
Mounting Type Through Hole Through Hole
Housing Material Liquid Crystal Polymer (LCP) Polyphthalamide (PPA), Glass Filled
Wire Termination Screwless - Leg Spring, Push-In Spring Screwless - Push Button Clamp
Contact Plating Tin Plated Electrolytic Copper - Tin Plated
RoHS Status ROHS3 Compliant ROHS3 Compliant
Product Status Active Active

Engineering Selection Recommendations

Both the Phoenix Contact 1822574 and WAGO 2086-3106 are active production components with full RoHS3 compliance and REACH unaffected status. Selection between these parts should be based on:

Primary Selection Criteria:

  • PCB layout compatibility with 5.00mm pitch and 6-position configuration
  • Wire termination method preference: leg spring push-in versus push-button clamp actuation
  • Housing material thermal and mechanical requirements for the application environment
  • Packaging format availability: tape & reel versus tray

Regulatory Compliance: Both parts satisfy ROHS3 and REACH requirements with MSL 1 (unlimited moisture sensitivity level), making them suitable for standard industrial applications without additional environmental controls.

Inventory Considerations: Phoenix Contact 1822574: 958 pcs available WAGO 2086-3106: 1049 pcs available

Frequently Asked Questions (FAQ)

Q: Can the WAGO 2086-3106 be used as a direct replacement for the Phoenix Contact 1822574 on existing PCBs?

A: Yes, provided the PCB footprint accommodates the 5.00mm pitch and 6-position through-hole configuration. Both parts share identical electrical ratings (10 A, 300 V) and wire gauge compatibility (16-24 AWG). Verify that the push-button clamp termination method of the WAGO part is compatible with your assembly and maintenance procedures.

Q: What is the difference in wire termination between these two parts?

A: The Phoenix Contact 1822574 uses leg spring and push-in spring termination, while the WAGO 2086-3106 uses push-button clamp termination. Both are screwless methods. The WAGO design requires button actuation for wire insertion and removal, whereas the Phoenix Contact design uses spring-loaded insertion.

Q: Are there operating temperature differences between these parts?

A: The Phoenix Contact 1822574 does not specify an operating temperature range in the provided data. The WAGO 2086-3106 operates from -60°C to 105°C. Verify temperature requirements for your specific application before selection.

Q: Do packaging differences affect component selection?

A: The Phoenix Contact 1822574 is supplied in tape & reel format, while the WAGO 2086-3106 is supplied in tray format. This affects handling, storage, and automated assembly compatibility. Select based on your production equipment and inventory management requirements.

Q: Are both parts RoHS3 compliant?

A: Yes, both the Phoenix Contact 1822574 and WAGO 2086-3106 are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory standards for industrial electronics.