Request Quote
(Ships tomorrow)
167V18 Equivalent & Substitute Parts
Part Overview
The Hammond Manufacturing 167V18 is a laminated core power transformer rated for 360VA with a 115V primary and 18V center-tapped secondary. This component is classified as obsolete, making equivalent substitutes necessary for ongoing system maintenance and new designs requiring compatible specifications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | 167V18 |
| Manufacturer | Hammond Manufacturing |
| Voltage - Primary | 115V |
| Voltage - Secondary (Full Load) | 18V |
| Current - Output (Max) | 20A |
| Power - Max | 360VA |
| Type | Laminated Core |
| Primary Winding(s) | Single |
| Secondary Winding(s) | Single |
| Center Tap | Yes |
| Mounting Type | Chassis Mount |
| Termination Style | Wire Leads |
| Voltage - Isolation | 2000Vrms |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
The 165V18 qualifies as a direct substitute based on the following critical parameters:
- Identical primary voltage: 115V
- Identical secondary voltage: 18V with center tap
- Identical maximum output current: 20A
- Identical power rating: 360VA
- Identical core type: Laminated
- Identical winding configuration: Single primary, single secondary
- Identical mounting type: Chassis Mount
- Identical termination style: Wire Leads
- Identical isolation voltage: 2000Vrms
- Identical RoHS compliance: ROHS3 Compliant
The 165V18 is active in production, addressing the obsolescence of the 167V18 while maintaining full electrical and mechanical compatibility.
Parameter Comparison
| Parameter | 167V18 (Main Part) | 165V18 (Substitute) |
|---|---|---|
| Manufacturer | Hammond Manufacturing | Hammond Manufacturing |
| Product Status | Obsolete | Active |
| Voltage - Primary | 115V | 115V |
| Voltage - Secondary (Full Load) | 18V | 18V |
| Current - Output (Max) | 20A | 20A |
| Power - Max | 360VA | 360VA |
| Type | Laminated Core | Laminated Core |
| Primary Winding(s) | Single | Single |
| Secondary Winding(s) | Single | Single |
| Center Tap | Yes | Yes |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Wire Leads | Wire Leads |
| Voltage - Isolation | 2000Vrms | 2000Vrms |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Size / Dimension | 95.25mm L x 114.30mm W | 114.30mm L x 101.60mm W |
| Height - Seated (Max) | 115.82mm | 95.25mm |
| Weight | 12 lbs (5.4 kg) | 11 lbs (5 kg) |
Engineering Selection Recommendations
The 165V18 is the direct equivalent for the obsolete 167V18. Both transformers share identical electrical specifications, core construction, and compliance certifications. The 165V18 is currently in active production with confirmed inventory availability.
Physical dimensions differ slightly between the two models. The 165V18 has a reduced height profile (95.25mm versus 115.82mm) and different length and width measurements. Verify mounting clearances in the target application before implementation.
Both parts maintain ROHS3 compliance and identical isolation voltage ratings, supporting equivalent performance in regulated environments.
Frequently Asked Questions (FAQ)
Q: Can the 165V18 directly replace the 167V18 in existing designs?
A: Yes, the 165V18 provides electrical equivalence across all critical parameters: primary voltage, secondary voltage, current rating, power capacity, winding configuration, and isolation voltage. Physical dimensions differ, requiring verification of mounting space availability.
Q: Are there compliance differences between the 167V18 and 165V18?
A: No. Both transformers are ROHS3 compliant with identical isolation voltage specifications (2000Vrms). Compliance certifications are equivalent.
Q: What are the dimensional differences between these parts?
A: The 167V18 measures 95.25mm L x 114.30mm W x 115.82mm H (seated), while the 165V18 measures 114.30mm L x 101.60mm W x 95.25mm H (seated). The 165V18 is shorter but has different length and width proportions. Confirm available mounting space before substitution.
Q: Do both transformers have center-tapped secondaries?
A: Yes. Both the 167V18 and 165V18 feature single center-tapped secondary windings rated at 18V, supporting identical circuit configurations.
Q: What is the weight difference?
A: The 167V18 weighs 12 lbs (5.4 kg), while the 165V18 weighs 11 lbs (5 kg). The difference reflects the dimensional variation between models.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts