167S11 Equivalent & Substitute Parts Reference

Part Overview

The 167S11 is a laminated core power transformer manufactured by Hammond Manufacturing, rated for 110VA with a 115V primary and 11V secondary output. This chassis-mount transformer features a center tap and wire lead termination, designed for applications requiring isolated low-voltage power distribution.

The 167S11 is classified as obsolete. Identifying equivalent substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing production or maintenance requirements for systems utilizing this transformer specification.

Substiute Parts

167S11
Hammond ManufacturingIn Stock: 781167S11 Datasheet
167S11
Current Part
166S11
Hammond ManufacturingIn Stock: 849166S11 Datasheet
166S11
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 167S11
Manufacturer Hammond Manufacturing
Series 167
Product Status Obsolete
Type Laminated Core
Voltage - Primary 115V
Voltage - Secondary (Full Load) 11V
Current - Output (Max) 10A
Power - Max 110VA
Primary Winding(s) Single
Secondary Winding(s) Single
Center Tap Yes
Mounting Type Chassis Mount
Termination Style Wire Leads
Voltage - Isolation 2000Vrms
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected

Substitute Part Grouping Explanation

Substitution of the 167S11 is based on electrical and mechanical compatibility across the following critical parameters:

  • Voltage specifications: Primary 115V and secondary 11V with center tap configuration
  • Power rating: 110VA maximum
  • Output current capacity: 10A maximum
  • Winding configuration: Single primary and single secondary
  • Isolation voltage: 2000Vrms
  • Mounting and termination: Chassis mount with wire leads
  • Regulatory compliance: ROHS3 and REACH status

The 166S11 meets all electrical specifications and regulatory requirements. Dimensional differences exist between the two models; however, both are chassis-mount configurations with wire lead termination suitable for equivalent circuit applications.

Parameter Comparison

Parameter 167S11 166S11
Manufacturer Hammond Manufacturing Hammond Manufacturing
Product Status Obsolete Active
Type Laminated Core Laminated Core
Voltage - Primary 115V 115V
Voltage - Secondary (Full Load) 11V 11V
Current - Output (Max) 10A 10A
Power - Max 110VA 110VA
Primary Winding(s) Single Single
Secondary Winding(s) Single Single
Center Tap Yes Yes
Mounting Type Chassis Mount Chassis Mount
Termination Style Wire Leads Wire Leads
Voltage - Isolation 2000Vrms 2000Vrms
Size / Dimension 64.60mm L x 82.55mm W 114.30mm L x 64.60mm W
Height - Seated (Max) 77.72mm 76.20mm
Weight 3.7 lbs (1.7 kg) 4.6 lbs (1.6 kg)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

The 166S11 is the direct substitute for the obsolete 167S11. Both transformers are manufactured by Hammond Manufacturing and share identical electrical specifications, winding configurations, and regulatory compliance certifications.

The 166S11 is currently in active production status with confirmed inventory availability, making it the appropriate selection for applications previously specified with the 167S11. Both parts maintain ROHS3 compliance and REACH unaffected status, ensuring compatibility with current environmental and regulatory requirements.

Dimensional variations exist between the two models. The 167S11 measures 64.60mm L x 82.55mm W x 77.72mm H, while the 166S11 measures 114.30mm L x 64.60mm W x 76.20mm H. Physical space constraints within the target application must be evaluated to confirm mounting compatibility.

Frequently Asked Questions (FAQ)

Q: Can the 166S11 directly replace the 167S11 in existing designs?

A: The 166S11 provides electrical equivalence to the 167S11 across all specified parameters: voltage ratings, power capacity, winding configuration, isolation voltage, and regulatory compliance. Physical dimensions differ; mounting space availability must be confirmed for the specific application.

Q: What is the primary reason for substitution?

A: The 167S11 is classified as obsolete. The 166S11 is an active production part from the same manufacturer with identical electrical specifications, ensuring continued availability for new production and maintenance applications.

Q: Are there compliance differences between the two parts?

A: No. Both the 167S11 and 166S11 are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory standards.

Q: What are the key electrical parameters that define substitution eligibility?

A: Substitution is based on matching primary voltage (115V), secondary voltage (11V), power rating (110VA), maximum output current (10A), center tap configuration, isolation voltage (2000Vrms), and winding topology (single primary, single secondary).

Q: Do packaging differences affect substitution?

A: The 167S11 is listed with dash packaging, while the 166S11 is supplied in bulk packaging. Both use wire lead termination and chassis mount configuration. Packaging designation does not affect electrical or mechanical compatibility.

Request Quote (Ships tomorrow)