Hammond Manufacturing 167P60 Equivalent & Substitute Parts

Part Overview

The Hammond Manufacturing 167P60 is a laminated core power transformer rated for 300VA with a 115V primary and 60V secondary output. This chassis-mounted transformer features a center tap and wire lead termination, designed for industrial and commercial applications requiring reliable power conversion. The 167P60 is classified as obsolete, making equivalent substitute parts necessary for ongoing system maintenance and new design implementations where this specification remains applicable.

Substiute Parts

167P60
Hammond ManufacturingIn Stock: 1013167P60 Datasheet
167P60
Current Part
165P60
Hammond ManufacturingIn Stock: 1142165P60 Datasheet
165P60
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 167P60
Manufacturer Hammond Manufacturing
Power Rating 300VA
Voltage - Primary 115V
Voltage - Secondary (Full Load) 60V
Current - Output (Max) 5A
Primary Winding(s) Single
Secondary Winding(s) Single
Center Tap Yes
Core Type Laminated
Mounting Type Chassis Mount
Termination Style Wire Leads
Voltage - Isolation 2000Vrms
RoHS Status ROHS3 Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

The Hammond Manufacturing 165P60 qualifies as a direct substitute for the 167P60 based on the following critical electrical and mechanical parameters:

Electrical Equivalence Criteria:

  • Identical primary voltage: 115V
  • Identical secondary voltage: 60V
  • Identical maximum output current: 5A
  • Identical power rating: 300VA
  • Identical center tap configuration: Yes
  • Identical primary and secondary winding count: Single/Single
  • Identical isolation voltage: 2000Vrms
  • Identical core type: Laminated

Mechanical Compatibility Criteria:

  • Identical mounting type: Chassis Mount
  • Identical termination style: Wire Leads
  • Compatible dimensions within chassis integration tolerance

Compliance Equivalence:

  • Identical RoHS3 compliance status
  • Identical REACH status (Unaffected)
  • Identical ECCN and HTSUS classifications

The 165P60 maintains active product status, ensuring ongoing availability and supply chain continuity compared to the obsolete 167P60.

Parameter Comparison

Parameter 167P60 (Main Part) 165P60 (Substitute)
Manufacturer Hammond Manufacturing Hammond Manufacturing
Product Status Obsolete Active
Power Rating 300VA 300VA
Voltage - Primary 115V 115V
Voltage - Secondary (Full Load) 60V 60V
Current - Output (Max) 5A 5A
Primary Winding(s) Single Single
Secondary Winding(s) Single Single
Center Tap Yes Yes
Core Type Laminated Laminated
Mounting Type Chassis Mount Chassis Mount
Termination Style Wire Leads Wire Leads
Voltage - Isolation 2000Vrms 2000Vrms
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Size / Dimension 95.25mm L x 114.30mm W 114.30mm L x 88.90mm W
Height - Seated (Max) 115.82mm 95.25mm
Weight 8.4 lbs (3.8 kg) 9 lbs (4.1 kg)

Engineering Selection Recommendations

The Hammond Manufacturing 165P60 is the appropriate substitute for the obsolete 167P60 based on complete electrical and mechanical equivalence across all specified parameters. Both transformers maintain identical electrical performance characteristics, winding configurations, and isolation ratings required for direct replacement in existing applications.

The 165P60 offers the advantage of active product status, ensuring reliable procurement and supply chain availability. Both parts maintain equivalent compliance certifications (ROHS3 and REACH Unaffected), supporting regulatory requirements in industrial and commercial installations.

Dimensional variations between the two models (165P60: 114.30mm L x 88.90mm W x 95.25mm H versus 167P60: 95.25mm L x 114.30mm W x 115.82mm H) require verification of chassis mounting clearances during integration. The weight difference (165P60: 9 lbs versus 167P60: 8.4 lbs) is within acceptable tolerance for standard mounting hardware.

Frequently Asked Questions (FAQ)

Q: Can the 165P60 directly replace the 167P60 in existing installations?

A: Yes. The 165P60 provides complete electrical equivalence with identical voltage ratings (115V primary, 60V secondary), power capacity (300VA), output current (5A), and isolation voltage (2000Vrms). Both transformers feature single primary and secondary windings with center tap configuration and wire lead termination.

Q: What are the key differences between these two models?

A: The primary differences are product status and physical dimensions. The 167P60 is obsolete while the 165P60 is active. Dimensional variations exist: the 165P60 measures 114.30mm L x 88.90mm W x 95.25mm H compared to the 167P60 at 95.25mm L x 114.30mm W x 115.82mm H. Both maintain identical electrical specifications and compliance certifications.

Q: Are there any compliance or certification differences?

A: No. Both the 167P60 and 165P60 maintain identical RoHS3 compliance and REACH Unaffected status. Both share the same ECCN (EAR99) and HTSUS (8504.31.4065) classifications.

Q: What should be considered during physical installation?

A: Verify that chassis mounting clearances accommodate the 165P60 dimensions (114.30mm L x 88.90mm W x 95.25mm H). The weight increase from 8.4 lbs to 9 lbs is negligible for standard mounting hardware. Wire lead termination remains consistent between both models.

Q: Why is the 167P60 listed as obsolete?

A: The 167P60 has been discontinued by Hammond Manufacturing. The 165P60 represents the current active equivalent, providing identical electrical performance with ongoing availability and supply chain support.

Request Quote (Ships tomorrow)