Request Quote
(Ships tomorrow)
Phoenix Contact 1642807 Heavy Duty Connector Hood - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 1642807 is a Heavy Duty Connector Hood for top entry applications with M32 thread size and B24 configuration. This connector provides IP65 ingress protection (dust tight, water resistant) and operates across a temperature range of -40°C to 100°C. The part is classified as obsolete, making identification of suitable substitute components essential for ongoing system maintenance and new design implementations where equivalent functionality is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1642807 |
| Manufacturer | Phoenix Contact |
| Category | Heavy Duty Connectors |
| Series | HEAVYCON® B |
| Connector Type | Hood |
| Style | Top Entry |
| Size | B24 |
| Thread Size | M32 |
| Ingress Protection Rating | IP65 |
| Operating Temperature Range | -40°C to 100°C |
| Housing Material | Aluminum, Die Cast |
| RoHS Status | RoHS Compliant |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 1642807 is determined by the following critical parameters:
Core Compatibility Parameters:
- Connector Type: Hood
- Style: Top Entry
- Size: B24
- Thread Size: M32
- Series: HEAVYCON® B
- Housing Material: Aluminum, Die Cast
Performance Parameters:
- Ingress Protection Rating: IP65 or higher
- Operating Temperature Range: Must accommodate -40°C minimum and 100°C maximum
- RoHS Compliance: Required for regulatory alignment
The substitute part 1412754 maintains identical core mechanical and electrical compatibility across all critical parameters. The substitute provides enhanced ingress protection (IP66/IP67/IP69K versus IP65) and extended operating temperature capability (-40°C to 125°C), representing a direct functional upgrade while preserving all mechanical interfaces and mounting requirements.
Parameter Comparison
| Parameter | 1642807 (Main Part) | 1412754 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Category | Heavy Duty Connectors | Heavy Duty Connectors |
| Series | HEAVYCON® B | HEAVYCON® B |
| Connector Type | Hood | Hood |
| Style | Top Entry | Top Entry |
| Size | B24 | B24 |
| Thread Size | M32 | M32 |
| Housing Material | Aluminum, Die Cast | Aluminum, Die Cast |
| Lock Location | Locking Clip (2) on Base Bottom | Locking Clip (2) on Base Bottom |
| Ingress Protection | IP65 | IP66/IP67/IP69K |
| Operating Temperature | -40°C to 100°C | -40°C to 125°C |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The Phoenix Contact 1412754 is the direct substitute for the obsolete 1642807. Both components share identical mechanical interfaces, mounting configurations, and core electrical specifications within the HEAVYCON® B series.
Selection Basis:
The 1412754 maintains full backward compatibility with all mechanical and electrical requirements of the 1642807. The substitute is currently in active production status, ensuring long-term availability and supply chain continuity. The enhanced ingress protection rating (IP66/IP67/IP69K) and extended operating temperature range (-40°C to 125°C) provide performance margins beyond the original specification without requiring any design modifications.
Both parts carry equivalent regulatory compliance certifications (RoHS), supporting identical deployment in regulated environments. The 1412754 is available in bulk packaging with 969 units in current inventory.
Frequently Asked Questions (FAQ)
Q: Can the 1412754 be used as a direct replacement for the 1642807 in existing installations?
A: Yes. The 1412754 maintains identical mechanical interfaces, thread sizing (M32), connector configuration (B24, Top Entry Hood), and mounting specifications. No mechanical or electrical modifications are required.
Q: What are the key differences between these two parts?
A: The primary differences are product status and environmental performance. The 1642807 is obsolete; the 1412754 is active production. The 1412754 provides enhanced ingress protection (IP66/IP67/IP69K versus IP65) and operates across a wider temperature range (-40°C to 125°C versus -40°C to 100°C).
Q: Are there any compatibility concerns with the dimensional differences noted?
A: The width dimension differs by 1mm (43mm versus 44mm). This represents a minor tolerance variation within the B24 form factor and does not affect mechanical mounting or electrical performance.
Q: Does the 1412754 require different installation procedures?
A: No. Both components use identical locking mechanisms (Locking Clip (2) on Base Bottom) and mounting interfaces. Installation procedures remain unchanged.
Q: What is the regulatory compliance status of the substitute?
A: The 1412754 carries ROHS3 compliance and REACH Unaffected status, meeting current regulatory requirements for heavy duty connector applications.
Q: Is the 1412754 available for immediate procurement?
A: Yes. The 1412754 is in active production with 969 units currently in inventory, available in bulk packaging.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts