Part Overview
The Phoenix Contact 1620447 is a 6-position (5 + PE) circular connector receptacle housing designed for panel mount, right-angle applications with a rotatable backshell. This connector features a metal shell with IP67 ingress protection and operates across a temperature range of -40°C to 125°C. The part is classified as obsolete, making identification of suitable substitute components essential for ongoing system maintenance and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1620447 |
| Manufacturer | Phoenix Contact |
| Category | Circular Connectors |
| Connector Type | Receptacle Housing |
| Number of Positions | 6 (5 + PE) |
| Shell Size - Insert | M17-6 |
| Mounting Type | Panel Mount, Right Angle |
| Fastening Type | Push-Twist |
| Ingress Protection | IP67 |
| Operating Temperature | -40°C to 125°C |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution of the Phoenix Contact 1620447 is determined by the following critical parameters that must remain consistent:
- Connector Type & Configuration: Receptacle housing for female sockets, 6-position (5 + PE) arrangement
- Shell Size: M17-6 insert size maintains mechanical and electrical compatibility
- Mounting Interface: Panel mount with right-angle orientation and flange mounting feature
- Ingress Protection: IP67 minimum rating for environmental sealing
- Operating Temperature Range: Minimum -40°C to 105°C overlap required
- Contact Termination: Crimp-type contacts for consistent mating performance
- Compliance: ROHS3 and REACH compliance maintained
The Phoenix Contact 1628514 qualifies as a direct substitute based on these parameters. Both connectors share identical shell size (M17-6), position count (6), mounting configuration (panel mount, right angle), and environmental protection rating (IP67/IP68). The 1628514 represents an active product from the PRO series, providing continuity for applications previously using the obsolete 1620447.
Parameter Comparison
| Parameter | 1620447 (Main Part) | 1628514 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Connector Type | Receptacle Housing | Receptacle, Female Sockets |
| Number of Positions | 6 (5 + PE) | 6 (5 + PE) |
| Shell Size - Insert | M17-6 | M17-6 |
| Mounting Type | Panel Mount, Right Angle | Panel Mount, Right Angle |
| Mounting Feature | Flange | Flange |
| Termination | Crimp | Crimp |
| Fastening Type | Push-Twist | Threaded |
| Orientation | N (Normal) | N (Normal) |
| Shell Material | Metal | Gadolinium-Zinc |
| Ingress Protection | IP67 | IP67/IP68 |
| Operating Temperature | -40°C to 125°C | -40°C to 105°C |
| Product Status | Obsolete | Active |
| RoHS Status | ROHS3 Compliant | Not specified |
| Shielding | Shielded | Unshielded |
| Current Rating | Not specified | 14A |
| Voltage Rating | Not specified | 630V |
Engineering Selection Recommendations
The Phoenix Contact 1628514 serves as the active product replacement for the obsolete 1620447. Selection of the 1628514 is supported by:
- Product Status Alignment: The 1628514 is an active product within Phoenix Contact's PRO series, ensuring ongoing availability and supply chain continuity
- Mechanical Compatibility: Identical shell size (M17-6), position configuration (6-position), and panel mount right-angle design ensure direct mechanical fit
- Environmental Protection: The 1628514 provides IP67/IP68 ingress protection, meeting or exceeding the IP67 requirement of the original part
- Compliance Maintenance: Both parts maintain EAR99 ECCN classification and REACH compliance status
- Operating Temperature Consideration: The 1628514 operates to 105°C maximum, which covers the majority of industrial applications within the -40°C to 105°C overlap range. Applications requiring operation above 105°C may require alternative evaluation
The primary design difference is the fastening mechanism: the 1620447 uses push-twist fastening while the 1628514 employs threaded fastening. This difference does not affect electrical or mechanical compatibility but may require procedural adjustment in mating operations.
Frequently Asked Questions (FAQ)
Q: Can the 1628514 directly replace the 1620447 in existing installations?
A: Yes, the 1628514 provides direct mechanical and electrical replacement. Both connectors share the M17-6 shell size, 6-position configuration, panel mount right-angle design, and IP67 environmental protection. The fastening mechanism differs (push-twist versus threaded), which affects mating procedure but not compatibility.
Q: What is the significance of the fastening type difference?
A: The 1620447 uses push-twist fastening while the 1628514 uses threaded fastening. Both methods provide secure mating connections. The threaded approach in the 1628514 may offer enhanced retention in high-vibration environments. Mating procedures will differ between the two designs.
Q: Does the operating temperature difference affect substitution?
A: The 1620447 operates to 125°C while the 1628514 operates to 105°C. For applications operating within the -40°C to 105°C range, the 1628514 is fully suitable. Applications requiring sustained operation above 105°C should evaluate alternative solutions.
Q: What is the difference between shielded and unshielded configurations?
A: The 1620447 is shielded while the 1628514 is unshielded. Shielding provides electromagnetic interference (EMI) protection. Applications requiring EMI suppression should evaluate whether the unshielded 1628514 meets performance requirements or if alternative shielded options are necessary.
Q: Are there packaging differences between these parts?
A: The 1620447 packaging is not specified in available documentation. The 1628514 is supplied in bulk packaging. Confirm packaging requirements with your procurement process.
Q: What compliance certifications apply to both parts?
A: Both parts maintain EAR99 ECCN classification and REACH compliance status. The 1620447 is explicitly ROHS3 compliant. RoHS compliance status for the 1628514 should be confirmed with the manufacturer.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts