Honeywell 14CE2-1K Equivalent & Substitute Parts

Part Overview

The Honeywell 14CE2-1K is a snap action SPDT switch with chassis mount configuration, rated for 5A at 250V AC. This component features a roller plunger actuator with IP66 ingress protection and cable lead termination. The product is classified as obsolete, making identification of compatible substitute parts essential for system maintenance and component sourcing.

Substiute Parts

14CE2-1K
Honeywell Sensing and Control EMEAIn Stock: 114914CE2-1K Datasheet
14CE2-1K
Current Part
D4C-1632
Omron Automation and SafetyIn Stock: 842D4C-1632 Datasheet
D4C-1632
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 14CE2-1K
Manufacturer Honeywell Sensing and Control EMEA
Series 14CE
Circuit Configuration SPDT
Switch Function On-Mom
Current Rating (AC) 5A
Voltage Rating (AC) 250V
Actuator Type Roller Plunger
Mounting Type Chassis Mount
Termination Style Cable Leads
Ingress Protection IP66
Cable Length 1m
Operating Temperature Range 0°C to 70°C
Mechanical Life 10,000,000 Cycles
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution compatibility for the 14CE2-1K is determined by the following critical parameters:

Primary Compatibility Criteria:

  • Circuit configuration: SPDT
  • Switch function: On-Mom
  • Current rating: 5A minimum (AC)
  • Voltage rating: 250V minimum (AC)
  • Actuator type: Roller Plunger
  • Mounting type: Chassis Mount
  • Termination style: Cable Leads

Secondary Compatibility Considerations:

  • Ingress protection rating: IP66 or higher
  • Operating temperature range: Must encompass or exceed 0°C to 70°C
  • Mechanical life: 10,000,000 cycles or greater

The Omron D4C-1632 meets all primary compatibility criteria and exceeds several secondary parameters, qualifying it as a direct substitute for the obsolete Honeywell 14CE2-1K.

Parameter Comparison

Parameter Honeywell 14CE2-1K Omron D4C-1632
Manufacturer Part Number 14CE2-1K D4C-1632
Manufacturer Honeywell Sensing and Control EMEA Omron Automation and Safety
Circuit Configuration SPDT SPDT
Switch Function On-Mom On-Mom
Current Rating (AC) 5A 5A
Voltage Rating (AC) 250V 250V
Actuator Type Roller Plunger Roller Plunger
Mounting Type Chassis Mount Chassis Mount
Termination Style Cable Leads Cable Leads
Ingress Protection IP66 IP67
Operating Temperature Range 0°C to 70°C -10°C to 70°C
Mechanical Life 10,000,000 Cycles 10,000,000 Cycles
RoHS Status RoHS Compliant ROHS3 Compliant
Product Status Obsolete Active

Engineering Selection Recommendations

The Omron D4C-1632 is the qualified substitute for the obsolete Honeywell 14CE2-1K. Both components share identical electrical ratings (5A at 250V AC) and mechanical specifications (SPDT circuit, On-Mom function, roller plunger actuator, chassis mount configuration).

The D4C-1632 provides enhanced specifications in the following areas:

  • Ingress protection upgraded from IP66 to IP67, providing waterproof capability
  • Extended operating temperature range (-10°C to 70°C versus 0°C to 70°C)
  • Active product status with current manufacturing support
  • ROHS3 compliance and REACH unaffected status

The D4C-1632 is suitable for direct replacement in applications where the original 14CE2-1K was specified, with the understanding that the substitute offers improved environmental protection and extended temperature operating range.

Frequently Asked Questions (FAQ)

Q: Can the Omron D4C-1632 directly replace the Honeywell 14CE2-1K?

A: Yes. Both components share identical circuit configuration (SPDT), switch function (On-Mom), current rating (5A AC), voltage rating (250V AC), actuator type (roller plunger), mounting type (chassis mount), and termination style (cable leads). The D4C-1632 meets all functional and electrical requirements for direct substitution.

Q: What are the key differences between these two parts?

A: The primary differences are ingress protection rating (IP67 versus IP66), operating temperature range (-10°C to 70°C versus 0°C to 70°C), cable length (3m versus 1m), and product status (active versus obsolete). The D4C-1632 provides enhanced environmental protection and extended temperature capability.

Q: Does the longer cable length of the D4C-1632 affect compatibility?

A: Cable length is a mechanical consideration that does not affect electrical compatibility. The 3m cable on the D4C-1632 provides greater installation flexibility compared to the 1m cable on the 14CE2-1K. Installation design must accommodate the available cable length.

Q: Are there compliance differences between these components?

A: Both components are RoHS compliant. The D4C-1632 carries ROHS3 compliance and REACH unaffected status, representing current regulatory alignment. The 14CE2-1K carries standard RoHS compliance.

Q: What mechanical life expectancy should be expected?

A: Both the Honeywell 14CE2-1K and Omron D4C-1632 are rated for 10,000,000 mechanical cycles, providing equivalent operational durability.

Request Quote (Ships tomorrow)